Finite element analysis of modified pedicle screw fixation and traditional lumbopelvic fixation for the treatment of sacroiliac joint disruption

被引:0
|
作者
Zhang, Jun [1 ]
Wei, Yan [2 ]
Yin, Weizhong [1 ]
Wang, Jian [1 ]
Liu, Bingli [3 ]
Ao, Rongguang [3 ]
Yu, Baoqing [3 ]
机构
[1] Pudong New Area Peoples Hosp, Dept Orthopaed, Shanghai 201299, Peoples R China
[2] Pudong New Area Peoples Hosp, Dept Surg, Shanghai 201299, Peoples R China
[3] Shanghai Univ TCM, Peoples Hosp 7, Dept Orthopaed, Shanghai 200137, Peoples R China
关键词
Sacroiliac joint disruption; Pedicle screw fixation; Lumbopelvic fixation; Internal fixation; Finite element analysis; FRACTURES; SACRUM; PLATE;
D O I
10.1186/s12891-024-08185-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionThe modified pedicle screw fixation (PSF) was designed to simulate an integrated framework structure to ameliorate the resistance to vertical and shearing forces of the disrupted sacroiliac complex, and the aim of this study was to compare the biomechanical characteristics of PSF and traditional lumbopelvic fixation (LPF) for the treatment of sacroiliac joint disruption.MethodsThe digital computer simulation model of an intact spine-pelvis-femur complex with main ligaments was built from clinical images. A left sacroiliac joint disruption model was mimicked by removing the concerned ligaments. After model validation, the two fixation models (modified PSF and traditional LPF) were established, and assembled with the disruption model. Under five loading scenarios (compression, flexion, extension, right bending, and left twisting), the finite element simulation was implemented. The maximum von Mises stress (VMS) of internal fixations and pelvises, maximum deformations on the Z-, Y-, X-axes and overall deformation of the sacrum were evaluated and compared.ResultsUnder all loading conditions, the maximum VMS of internal fixations and pelvises in the modified PSF model were lower than those in the traditional LPF model. Under flexion, right bending, and left twisting, the maximum Z-axis deformation of the sacrum for the modified PSF model was smaller than that of the traditional LPF model. For compression, the maximum Y-axis deformation of the sacrum was smaller than that of the traditional LPF model. During various loading modes, the maximum X-axis, and overall deformations of the sacrum for the modified PSF model were smaller than those in the traditional LPF model.ConclusionsCompared with the traditional LPF, the modified PSF shows superior biomechanical stability, with satisfied resistance to vertical and shearing forces, which might be potentially suitable for treating sacroiliac joint disruption.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Comparison of mechanical stability of modified pedicle screw fixator and unilateral lumbopelvic fixation for treating sacroiliac joint disruption: A finite element analysis study
    Zhang, Jun
    Wei, Yan
    Yu, Baoqing
    Wang, Jian
    Yin, Weizhong
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2024, 58 (05)
  • [2] Finite element analysis of sacral-alar-iliac screw fixation for sacroiliac joint dislocation
    Zhang, Wei
    Cheng, Yucheng
    Diarra, Mohamed Diaty
    Chen, Erman
    Hou, Weiduo
    Xin, Zengfeng
    Pan, Zhijun
    Li, Weixu
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (08) : 1821 - 1830
  • [3] Sacroiliac Joint Degeneration After Lumbopelvic Fixation
    Nakashima, Hiroaki
    Kanemura, Tokumi
    Satake, Kotaro
    Ito, Kenyu
    Tanaka, Satoshi
    Segi, Naoki
    Ouchida, Jun
    Kagami, Yujiro
    Ando, Kei
    Kobayashi, Kazuyoshi
    Imagama, Shiro
    GLOBAL SPINE JOURNAL, 2022, 12 (06) : 1158 - 1164
  • [4] Axis screw parallel to the sagittal plane versus traditional pedicle screw in the treatment of atlantoaxial fixation: a finite element study
    Zeng, Baifang
    Ding, Meng
    Li, Lang
    Wu, Chao
    Qin, Bingwei
    Shen, Danwei
    Deng, Jiayan
    Wang, Xiangyu
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [5] Biomechanical Comparison of a Novel Facet Joint Fusion Fixation Device With Conventional Pedicle Screw Fixation Device: A Finite Element Analysis
    Sun, Feilong
    Qiu, Haiyang
    Ji, Yufei
    Wang, Longchao
    Lei, Wei
    Zhang, Yang
    ORTHOPAEDIC SURGERY, 2025, 17 (04) : 1230 - 1242
  • [6] Finite Element Analysis of Sacroiliac Joint Fixation under Compression Loads
    Bruna-Rosso, Claire
    Arnoux, Pierre-Jean
    Bianco, Rohan-Jean
    Godio-Raboutet, Yves
    Fradet, Leo
    Aubin, Carl-Eric
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2016, 10
  • [7] Transperitoneal screw fixation of the sacroiliac joint
    Bijlsma, TS
    Van der Werken, C
    Dell'Oca, AF
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2000, 49 (01): : 152 - 155
  • [8] Biomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis
    Tao Wu
    Xuejiao Ren
    Yunwei Cui
    Xiaodong Cheng
    Shuo Peng
    Zhiyong Hou
    Yongtai Han
    Journal of Orthopaedic Surgery and Research, 13
  • [9] Biomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis
    Wu, Tao
    Ren, Xuejiao
    Cui, Yunwei
    Cheng, Xiaodong
    Peng, Shuo
    Hou, Zhiyong
    Han, Yongtai
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [10] Treatment of Unstable Thoracolumbar Fractures through Short Segment Pedicle Screw Fixation Techniques Using Pedicle Fixation at the Level of the Fracture: A Finite Element Analysis
    Li, Changqing
    Zhou, Yue
    Wang, Hongwei
    Liu, Jun
    Xiang, Liangbi
    PLOS ONE, 2014, 9 (06):