Changing rod stiffness to moderate stress of adjacent disc in oblique lumbar interbody fusion - a finite element analysis

被引:0
|
作者
Chou, Po-Hsin [1 ,2 ]
Chen, Jing-Jie [3 ]
Chen, Chen-Sheng [4 ]
Wang, Shih-Tien [2 ]
Liu, Chien-Lin [2 ]
Shih, Shih-Liang [4 ,5 ]
机构
[1] Natl Yang Ming Chiao Tung Univ, Sch Med, Taipei, Taiwan
[2] Taipei Vet Gen Hosp, Dept Orthoped & Traumatol, Taipei, Taiwan
[3] I Shou Univ, Dept Biomed Engn, Kaohsiung, Taiwan
[4] Natl Yang Ming Chiao Tung Univ, Dept Phys Therapy & Assist Technol, 155,Sec 2,Li Nung St, Taipei 112, Taiwan
[5] Taipei City Hosp, Dept Orthopaed Surg, Zhong Xing Branch, 145 Zhengzhou Rd, Taipei 10341, Taiwan
关键词
OLIF; Adjacent segment; Lumbar spine; Finite element analysis; LOW-BACK-PAIN; SURGERY; SPINE; DEGENERATION; FIXATION; SEGMENT; DISEASE;
D O I
10.1186/s12891-025-08504-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundOLIF (oblique lumbar interbody fusion) is a minimally invasive surgery to treat spinal instability. However, clinical studies indicated the early degeneration of adjacent segments after surgery. The rod stiffness of OLIF was associated with change at adjacent segments. Therefore, the study aimed to compare the biomechanical effects of OLIF with different rod material properties using the finite element (FE) method.MethodsA validated L1-L5 lumbar spine was conducted in the biomechanical analysis using FE software ANSYS. The FE model of OLIF with a rod was created. Current biocompatible materials for the rod of the OLIF model were changed, including titanium alloy (OLIF_Ti), nickel-titanium alloy (OLIF_NiTi), and polycarbonate urethane (OLIF_PCU) rod. Four FE models, consisting of the intact model (INT) and implant models, were created. Hybrid control loads, such as flexion, extension, rotation, and lateral bending, were subjected to four models on the L1 vertebral body. The bottom of the L5 vertebral body was fixed.ResultsAt the surgical level, while compared to the INT model, the OLIF_Ti and OLIF_NiTi model resulted in a ROM reduction of over 40% at least, but the OLIF_PCU changed about 10% in flexion and extension. At adjacent level L2-L3, the FE results indicated that the OLIF_Ti and OLIF_NiTi model increased more stress by about 12% at least than the INT model at the adjacent segment, but it demonstrated that the OLIF_PCU would not result in stress rise at the adjacent level L2-L3 in flexion and extension.ConclusionThe study concluded that rod stiffness was associated with change at the adjacent segments. The use of OLIF surgery with PCU rods can minimize the impact of the adjacent segment after lumbar fusion.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Determining a relative total lumbar range of motion to alleviate adjacent segment degeneration after transforaminal lumbar interbody fusion: a finite element analysis
    Ke Li
    Shuai Cao
    Jing Chen
    Jie Qin
    Bo Yuan
    Jie Li
    BMC Musculoskeletal Disorders, 25
  • [42] Determining a relative total lumbar range of motion to alleviate adjacent segment degeneration after transforaminal lumbar interbody fusion: a finite element analysis
    Li, Ke
    Cao, Shuai
    Chen, Jing
    Qin, Jie
    Yuan, Bo
    Li, Jie
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [43] Oblique lateral interbody fusion combined with different internal fixations for the treatment of degenerative lumbar spine disease: a finite element analysis
    Shuyi Zhang
    Zhengpeng Liu
    Chenshui Lu
    Li Zhao
    Chao Feng
    Yahui Wang
    Yilong Zhang
    BMC Musculoskeletal Disorders, 23
  • [44] Oblique lateral interbody fusion combined with different internal fixations for the treatment of degenerative lumbar spine disease: a finite element analysis
    Zhang, Shuyi
    Liu, Zhengpeng
    Lu, Chenshui
    Zhao, Li
    Feng, Chao
    Wang, Yahui
    Zhang, Yilong
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [45] Biomechanical study of two-level oblique lumbar interbody fusion with different types of lateral instrumentation: a finite element analysis
    Zhong, Yuan
    Wang, Yujie
    Zhou, Hong
    Wang, Yudong
    Gan, Ziying
    Qu, Yimeng
    Hua, Runjia
    Chen, Zhaowei
    Chu, Genglei
    Liu, Yijie
    Jiang, Weimin
    FRONTIERS IN MEDICINE, 2023, 10
  • [46] Comparative Biomechanical Analysis of Unilateral, Bilateral, and Lateral Pedicle Screw Implantation in Oblique Lumbar Interbody Fusion: A Finite Element Study
    Pan, Chien-Chou
    Lee, Cheng-Hung
    Chen, Kun-Hui
    Yen, Yu-Chun
    Su, Kuo-Chih
    BIOENGINEERING-BASEL, 2023, 10 (11):
  • [47] Finite Element Analysis of a Novel Fusion Strategy in Minimally Invasive Transforaminal Lumbar Interbody Fusion
    Han, Zhenchuan
    Ren, Bowen
    Zhang, Long
    Ma, Chao
    Liu, Jianheng
    Li, Jiantao
    Liu, Xiao
    Liu, Qingzu
    Mao, Keya
    Tang, Peifu
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [48] Oblique lumbar interbody fusion for adjacent segment disease after posterior lumbar fusion: a case-controlled study
    Cong Jin
    Minghua Xie
    Lei He
    Wenbin Xu
    Weiqi Han
    Wengqing Liang
    Yu Qian
    Journal of Orthopaedic Surgery and Research, 14
  • [49] Oblique lumbar interbody fusion for adjacent segment disease after posterior lumbar fusion: a case-controlled study
    Jin, Cong
    Xie, Minghua
    He, Lei
    Xu, Wenbin
    Han, Weiqi
    Liang, Wengqing
    Qian, Yu
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (1)
  • [50] Fusion rate and complications of oblique lumbar interbody fusion and transforaminal lumbar interbody fusion in the treatment of lumbar degenerative diseases: a meta-analysis
    Xiao, Xun
    Duan, Heng
    Pan, Xin
    Zhao, Hua
    FRONTIERS IN SURGERY, 2024, 11