The effect of autoclave cycles on the mechanical properties and surface roughness of NiTi archwires: ex-vivo study

被引:0
|
作者
El Shahawi, Amal Magdi [1 ]
Aboalnaga, Amira Ahmed [2 ]
机构
[1] Natl Res Ctr, Oral & Dent Res Inst, Restorat & Dent Mat Dept, Cairo, Egypt
[2] Cairo Univ, Fac Dent, Dept Orthodont & Dentofacial Orthoped, Cairo, Egypt
来源
BMC ORAL HEALTH | 2024年 / 24卷 / 01期
关键词
Mechanical properties; Surface roughness; Clinical recycling; Rapid-cycle autoclaving; Universal-cycle autoclaving; TI WIRES; STERILIZATION; TOPOGRAPHY;
D O I
10.1186/s12903-024-04877-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To evaluate the effect of the universal and rapid autoclave cycles on the mechanical properties and surface roughness of nickel-titanium archwires following clinical use. Material and methods Thirty-six NiTi archwires (0.016 x 0.022 inch) were equally divided into a control group (Group A) and 2 experimental groups (Group B & C). Wires in group A were tested in the "as-received" form. Wires in the two other groups were installed in patients mouth for 4 weeks, and then autoclaved using the rapid- cycle (Group B) or the universal- cycle (Group C). All wires were subjected to 3-point bending test to calculate the elastic limit, modulus of elasticity, spring-back, yield strength, resilience and toughness. Atomic force microscopy (AFM) was used for surface roughness qualitative and quantitative analysis. Results Group B showed significantly higher values of elastic limit, modulus of elasticity, resilience, yield strength and toughness than the other two groups. No significant differences were detected between groups A and C (P > 0.05). Group B showed significantly lower average surface roughness than the other two groups, but no significant differences were detected between groups A and C (P > 0.05). Conclusions The mechanical properties and surface roughness of clinically used NiTi wires were less affected by the universal-cycle than the rapid- cycle autoclaving. However, the difference between the effect of both autoclave cycles was diminutive. Clinical relevance The mechanical properties and surface roughness of the tested NiTi wires were not notably altered by clinical use and autoclaving.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Comparison of the mechanical properties and surface topography of as-received and as- retrieved Copper-Nickel-Titanium arch wires: An ex-vivo study
    Babanouri, Neda
    Sarbaz, Maryam
    Alamdarloo, Yasaman
    Haghighat, Meisam
    Ajami, Shabnam
    INTERNATIONAL ORTHODONTICS, 2023, 21 (01)
  • [22] Effect of electric field direction on neuronal activity: an ex-vivo study
    Jaint, Vishal
    Forssell, Mats
    Chamanzar, Maysamreza
    Grover, Pulkit
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [23] Simulation of the Effect of Surface Roughness on the Mechanical Properties of a Microbeam
    Fang, Wen-Xiao
    Huang, Qin-Wen
    Liu, Xin
    Qiu, Chu-Xuan
    2011 INTERNATIONAL CONFERENCE ON QUALITY, RELIABILITY, RISK, MAINTENANCE, AND SAFETY ENGINEERING (ICQR2MSE), 2011, : 1000 - 1003
  • [24] Reinforcement bronchial stump increases early mechanical integrity: an ex-vivo experimental study
    Yeginsu, A.
    Ergin, M.
    ACTA CHIRURGICA BELGICA, 2008, 108 (02) : 240 - 243
  • [25] A Study of the Dielectric Properties of Biological Tissues: Ex-vivo vs Preserved Samples
    Alborova, Irina L.
    Bonello, Julian
    Farrugia, Lourdes
    Sammut, Charles V.
    Anishchenko, Lesya N.
    2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS), 2017, : 2373 - 2377
  • [26] THE DIELECTRIC PROPERTIES OF UPPER GASTROINTESTINAL TISSUE TYPES - AN EX-VIVO FEASIBILITY STUDY
    Samaddar, Poulami
    Steinfort, Luz Maria Neira
    Fetzer, Jeffrey
    Arunachalam, Shivaram Poigai
    Wang, Kenneth K.
    Leggett, Cadman L.
    GASTROENTEROLOGY, 2022, 162 (07) : S1026 - S1026
  • [27] Static compression optical coherence elastography for the measurement of porcine corneal mechanical properties ex-vivo
    Quince, Zachery
    Alonso-Caneiro, David
    Read, Scott A.
    Harkin, Damien G.
    Collins, Michael J.
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2024, 44 (03) : 609 - 616
  • [28] The effect of nanobased irrigants on the root canal dentin microhardness: an ex-vivo study
    Sahebi, Safoora
    Mofidi, Hossein
    Abbaszadegan, Abbas
    Gholami, Ahmad
    Eskandari, Fateme
    BMC ORAL HEALTH, 2023, 23 (01)
  • [29] The effect of femoral orientation on the measurement of the head shaft angle: an ex-vivo study
    Wordie, Sarah J.
    Gaston, Mark S.
    Hagglund, Gunnar
    Czuba, Tomasz
    Robb, James E.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2019, 28 (05): : 465 - 469
  • [30] The effect of nanobased irrigants on the root canal dentin microhardness: an ex-vivo study
    Safoora Sahebi
    Hossein Mofidi
    Abbas Abbaszadegan
    Ahmad Gholami
    Fateme Eskandari
    BMC Oral Health, 23