The effect of autoclave cycles on the mechanical properties and surface roughness of NiTi archwires: ex-vivo study

被引:0
|
作者
El Shahawi, Amal Magdi [1 ]
Aboalnaga, Amira Ahmed [2 ]
机构
[1] Natl Res Ctr, Oral & Dent Res Inst, Restorat & Dent Mat Dept, Cairo, Egypt
[2] Cairo Univ, Fac Dent, Dept Orthodont & Dentofacial Orthoped, Cairo, Egypt
来源
BMC ORAL HEALTH | 2024年 / 24卷 / 01期
关键词
Mechanical properties; Surface roughness; Clinical recycling; Rapid-cycle autoclaving; Universal-cycle autoclaving; TI WIRES; STERILIZATION; TOPOGRAPHY;
D O I
10.1186/s12903-024-04877-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To evaluate the effect of the universal and rapid autoclave cycles on the mechanical properties and surface roughness of nickel-titanium archwires following clinical use. Material and methods Thirty-six NiTi archwires (0.016 x 0.022 inch) were equally divided into a control group (Group A) and 2 experimental groups (Group B & C). Wires in group A were tested in the "as-received" form. Wires in the two other groups were installed in patients mouth for 4 weeks, and then autoclaved using the rapid- cycle (Group B) or the universal- cycle (Group C). All wires were subjected to 3-point bending test to calculate the elastic limit, modulus of elasticity, spring-back, yield strength, resilience and toughness. Atomic force microscopy (AFM) was used for surface roughness qualitative and quantitative analysis. Results Group B showed significantly higher values of elastic limit, modulus of elasticity, resilience, yield strength and toughness than the other two groups. No significant differences were detected between groups A and C (P > 0.05). Group B showed significantly lower average surface roughness than the other two groups, but no significant differences were detected between groups A and C (P > 0.05). Conclusions The mechanical properties and surface roughness of clinically used NiTi wires were less affected by the universal-cycle than the rapid- cycle autoclaving. However, the difference between the effect of both autoclave cycles was diminutive. Clinical relevance The mechanical properties and surface roughness of the tested NiTi wires were not notably altered by clinical use and autoclaving.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Ex vivo surface and mechanical properties of coated orthodontic archwires
    Elayyan, Firas
    Silikas, Nick
    Bearn, David
    EUROPEAN JOURNAL OF ORTHODONTICS, 2008, 30 (06) : 661 - 667
  • [2] The effect of topical fluoride agents on the physical and mechanical properties of NiTi and copper NiTi archwires. An in vivo study
    Ramalingam, Arthi
    Kailasam, Vignesh
    Padmanabhan, Sridevi
    Chitharanjan, Arun
    AUSTRALIAN ORTHODONTIC JOURNAL, 2008, 24 (01) : 26 - 31
  • [3] Evaluating the effect of clinical usage and autoclave sterilization on the load deflection properties of three different orthodontic wires: Ex-vivo study
    Najafi, Hooman Zarif
    Gavareshki, Sepideh Rezapour
    INTERNATIONAL ORTHODONTICS, 2019, 17 (03) : 469 - 477
  • [4] Evaluation of the Effect of Different Types of Fluoride on Tensile Properties and Surface Roughness of Different Titanium-Based Archwires: An In vivo Study
    Balakrishnan, Rajkumar
    Jeri, Sumaya Yousuf
    Rekha, V. R.
    Singh, Gangesh Bahadur
    Deepak, P. R.
    Nair, Achuthan
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (06): : S1193 - S1198
  • [5] Surface Ultrastructure and Mechanical Properties of Three Different White-Coated NiTi Archwires
    Ryu, Seong-Hee
    Lim, Byung-Suh
    Kwak, Eun Joo
    Lee, Gi-Ja
    Choi, Samjin
    Park, Ki-Ho
    SCANNING, 2015, 37 (06) : 414 - 421
  • [6] Comparison of surface roughness and hardness of three different brands of esthetic coated NiTi archwires: invitro study
    Aboalnaga, Amira A.
    El Shahawi, Amal M.
    BMC ORAL HEALTH, 2023, 23 (01)
  • [7] Comparison of surface roughness and hardness of three different brands of esthetic coated NiTi archwires: invitro study
    Amira A. Aboalnaga
    Amal M. El Shahawi
    BMC Oral Health, 23
  • [8] Study of mechanical properties and biocompatibility of tantalum-containing coatings on NiTi orthodontic archwires
    Soltanalipour, Mahdiyeh
    Khalil-Allafi, Jafar
    TRANSACTIONS OF THE INSTITUTE OF METAL FINISHING, 2025, 103 (02): : 72 - 81
  • [9] Mucoadhesive polymer films for tissue retraction in laparoscopic surgery: Ex-vivo study on their mechanical properties
    Wang, Zhigang
    Tai, Lik-Ren
    McLean, Donald
    Wright, Emma J.
    Florence, Gordon J.
    Brown, Stuart I.
    Andre, Pascal
    Cuschieri, Alfred
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 445 - 451
  • [10] Influence of different storage temperatures on the mechanical properties of NiTi, Cu-NiTi and SS orthodontic archwires: An in vitro study
    Friedli, Luca
    Nalabothu, Prasad
    Bosch, Carles
    Verna, Carlalberta
    Steineck, Markus
    Dalstra, Michel
    INTERNATIONAL ORTHODONTICS, 2020, 18 (03) : 561 - 568