Noise Reduction Scheme for Air-Cooled Heat Pump Unit

被引:0
|
作者
Zhou, Qi [1 ]
Huang, Wenjian [1 ]
Cao, Shiyu [1 ]
Wu, Chaoqun [1 ,2 ]
Lei, Ting [1 ]
机构
[1] Wuhan Univ Technol, Sch Mech & Elect Engn, Hubei Digital Mfg Key Lab, Wuhan, Hubei, Peoples R China
[2] Wuhan Univ Technol, Robot & Intelligent Mfg Hubei Engn Res Ctr, Sch Mech & Elect Engn, Wuhan, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
Air-cooled heat pump; Noise measurement; Noise control; Acoustic enclosure;
D O I
10.1007/s42417-024-01727-z
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
PurposeThe air-cooled heat pump unit is widely used in the central air-conditioning system in large buildings such as shopping malls and hospitals. However, the noise emitted from the air-cooled heat pump units affects the life and work of the surrounding residents seriously. Therefore, it is of great importance to reduce the noise emission of the air-cooled heat pump units.MethodIn this study, the noise characteristics of a heat pump unit (type: YSPA0405HE) were measured. It was found that the sound pressure level reached 68 dB at the residential buildings and most noise energy concentrated in the 250-1000 Hz frequency band. To reduce the noise emission, we designed a semi-enclosed acoustic enclosure to isolate noise, in which labyrinth-style inlet and outlet channels were adopt to reduce noise spreading and ensure adequate air intake.ResultsThe noise level at the residential buildings was measured with and without installation of the acoustic enclosure. Results shown that more than 10 dB noise reduction is achieved at the residential buildings, which reached the national standard for the noise level of the second-class acoustic environment area.ConclusionThis study provides a reference engineering example for the noise reduction of related heat pump units.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Avoid operating problems in air-cooled heat exchangers
    Mukherjee, R
    HYDROCARBON PROCESSING, 1997, 76 (03): : 69 - &
  • [32] REDUCING SOLIDIFICATION IN AIR-COOLED HEAT-EXCHANGERS
    ROZENMAN, T
    PUNDYK, J
    CHEMICAL ENGINEERING PROGRESS, 1974, 70 (10) : 80 - 85
  • [33] Optimization of flow paths of air-cooled heat exchangers
    Kumar R.
    Krishnapillai S.
    Venkatarathnam G.
    International Journal of Energy for a Clean Environment, 2023, 24 (04) : 53 - 65
  • [34] METHODOLOGY FOR THE UTILIZATION OF WASTE HEAT BY AIR-COOLED COMPRESSORS
    Pacas, Lukas
    MM SCIENCE JOURNAL, 2021, 2021 : 4918 - 4923
  • [35] SELECTING AND SPECIFYING AIR-COOLED HEAT-EXCHANGERS
    BAKER, WJ
    HYDROCARBON PROCESSING, 1980, 60 (05): : 173 - 177
  • [36] Improving the energy efficiency of air-cooled heat exchangers
    Kuntysh, VB
    Bessonnyi, AN
    Brill, AA
    CHEMICAL AND PETROLEUM ENGINEERING, 1997, 33 (04) : 402 - 407
  • [37] Air-cooled heat exchanger inlet flow losses
    Meyer, CJ
    Kröger, DG
    APPLIED THERMAL ENGINEERING, 2001, 21 (07) : 771 - 786
  • [38] AIR-COOLED HEAT-EXCHANGERS - CONVENTIONAL AND UNCONVENTIONAL
    KALS, W
    HYDROCARBON PROCESSING, 1994, 73 (08): : 138 - 140
  • [39] On the Efficiency of Air-Cooled Metal Foam Heat Exchangers
    Fiedler, Thomas
    Movahedi, Nima
    Stanger, Rohan
    METALS, 2024, 14 (07)
  • [40] Improving the energy efficiency of air-cooled heat exchangers
    V. B. Kuntysh
    A. N. Bessonnyi
    A. A. Brill'
    Chemical and Petroleum Engineering, 1997, 33 : 402 - 407