Intermittently scanned continuous glucose monitoring compared with blood glucose monitoring is associated with lower HbA1c and a reduced risk of hospitalisation for diabetes-related complications in adults with type 2 diabetes on insulin therapies

被引:0
|
作者
Nathanson, David [1 ,2 ]
Eeg-Olofsson, Katarina [3 ,4 ]
Spelman, Tim [5 ]
Buelow, Erik [4 ]
Kyhlstedt, Mattias [5 ]
Levrat-Guillen, Fleur [6 ]
Bolinder, Jan [1 ]
机构
[1] Karolinska Univ, Hosp Huddinge, Karolinska Inst, Dept Med, Stockholm, Sweden
[2] Karolinska Univ, Hosp Huddinge, Med Unit Endocrinol, Stockholm, Sweden
[3] Univ Gothenburg, Sahlgrenska Univ Hosp, Dept Mol & Clin Med, Sahlgrenska Univ Hosp, Gothenburg, Sweden
[4] Ctr Registries Vastra Gotaland Reg, Gothenburg, Sweden
[5] Synergus RWE AB, Akersperga, Sweden
[6] Abbott Labs Ltd, Maidenhead, England
关键词
Cardiovascular disease; CGM; Hospitalisation; Insulin treated; Intermittently scanned; Swedish National Diabetes Register; Swedish National Patient Register; Type; 2; diabetes; SENSING TECHNOLOGY; RANGE; TIME; STANDARDIZATION; REPLACEMENT;
D O I
10.1007/s00125-024-06289-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims/hypothesisWe assessed the impact of initiating intermittently scanned continuous glucose monitoring (isCGM) compared with capillary blood glucose monitoring (BGM) on HbA1c levels and hospitalisations for diabetes-related complications in adults with insulin-treated type 2 diabetes in Sweden.MethodsThis retrospective comparative cohort study included adults with type 2 diabetes who had a National Diabetes Register initiation date for isCGM after 1 June 2017. Prescribed Drug Register records identified subgroups treated with multiple daily insulin injections (T2D-MDI) or basal insulin (T2D-B), with or without other glucose-lowering drugs. The National Patient Register provided data on hospitalisation rates.ResultsWe identified 2876 adults in the T2D-MDI group and 2292 in the T2D-B group with an isCGM index date after 1 June 2017, matched with 33,584 and 43,424 BGM control participants, respectively. The baseline-adjusted difference in the change in mean HbA1c for isCGM users vs BGM control participants in the T2D-MDI cohort was -3.7 mmol/mol (-0.34%) at 6 months, and this was maintained at 24 months. The baseline-adjusted difference in the change in HbA1c for isCGM users vs BGM control participants in the T2D-B cohort was -3.5 mmol/mol (-0.32%) at 6 months, and this was also maintained at 24 months. Compared with BGM control participants, isCGM users in the T2D-MDI cohort had a significantly lower RR of admission for severe hypoglycaemia (0.51; 95% CI 0.27, 0.95), stroke (0.54; 95% CI 0.39, 0.73), acute non-fatal myocardial infarction (0.75; 95% CI 0.57, 0.99) or hospitalisation for any reason (0.84; 95% CI 0.77, 0.90). isCGM users in the T2D-B cohort had a lower RR of admission for heart failure (0.63; 95% CI 0.46, 0.87) or hospitalisation for any reason (0.76; 95% CI 0.69, 0.84).Conclusions/interpretationThis study shows that Swedish adults with type 2 diabetes on insulin who are using isCGM have a significantly reduced HbA1c and fewer hospital admissions for diabetes-related complications compared with BGM control participants.
引用
收藏
页码:41 / 51
页数:11
相关论文
共 50 条
  • [21] Change in HbA1c with and without intermittent use of continuous glucose monitoring in adults with type 2 diabetes participating in a virtual diabetes clinic
    Layne, J. E.
    Zisser, H.
    Bergenstal, R. M.
    Gabbay, R. A.
    Barleen, N. A.
    Lee, A. Armento
    Dixon, R. F.
    DIABETOLOGIA, 2020, 63 (SUPPL 1) : S54 - S54
  • [22] Impact of 6 months' Use of Intermittently Scanned Continuous Glucose Monitoring on Habitual Sleep Patterns and Sleep Quality in Adolescents and Young Adults with Type 1 Diabetes and High-Risk HbA1c
    Rose, Shelley
    Galland, Barbara C.
    Styles, Sara E.
    Wiltshire, Esko J.
    Stanley, James
    de Bock, Martin I.
    Tomlinson, Paul A.
    Rayns, Jenny A.
    Wheeler, Benjamin J.
    PEDIATRIC DIABETES, 2023, 2023
  • [23] Intermittently-scanned CGM is associated with lower HbA1c and reduced hospital admissions for adults with type 2 diabetes on insulin therapy in Sweden: a retrospective controlled study
    Nathanson, D.
    Eeg-Olofsson, K.
    Spelman, T.
    Bulow, E.
    Kyhlstedt, M.
    Levrat-Guillen, F.
    Bolinder, J.
    DIABETOLOGIA, 2023, 66 (SUPPL 1) : S422 - S422
  • [24] Performance of intermittently scanned continuous glucose monitoring systems in people with type 1 diabetes: A pooled analysis
    Moser, Othmar
    Sternad, Christoph
    Eckstein, Max L.
    Szadkowska, Agnieszka
    Michalak, Arkadiusz
    Mader, Julia K.
    Ziko, Haris
    Elsayed, Hesham
    Aberer, Felix
    Sola-Gazagnes, Agnes
    Larger, Etienne
    Fadini, Gian Poalo
    Bonora, Benedetta Maria
    Bruttomesso, Daniela
    Boscari, Federico
    Freckmann, Guido
    Pleus, Stefan
    Christiansen, Sverre C.
    Sourij, Harald
    DIABETES OBESITY & METABOLISM, 2022, 24 (03): : 522 - 529
  • [25] Flash glucose monitoring improves HbA1c in people with type 1 diabetes
    Harte, R.
    Connelly, P.
    Drummond, R.
    Carty, D.
    Osborne, L.
    Cleland, S.
    Kennon, B.
    Hopkinson, H.
    Smith, C.
    Boyle, J. G.
    DIABETIC MEDICINE, 2020, 37 : 147 - 147
  • [26] SELF BLOOD GLUCOSE MONITORING UNDERESTIMATES HYPERGLYCEMIA AND HYPOGLYCEMIA AS COMPARED TO CONTINUOUS GLUCOSE MONITORING IN TYPE 1 AND TYPE 2 DIABETES
    Mangrola, Devna
    Cox, Christine
    Furman, Arianne S.
    Krishnan, Sridevi
    Karakas, Sidika E.
    ENDOCRINE PRACTICE, 2018, 24 (01) : 47 - 52
  • [27] Intermittently scanned continuous glucose monitoring provides no benefit over structured self-monitoring of blood glucose in type 2 diabetes not on prandial insulin, in the context of diabetes self-management education: GLucose monitoring programme SingaporE (GLiMPSE)
    Chandran, Suresh Rama
    Rahman, Nabilah
    Gandhi, Mihir
    Tan, Ngiap Chuan
    Phoon, Ian K. Y.
    Seah, Darren E. J.
    Cheah, Ming Hann
    Sek, Kathleen
    Gardner, Daphne Su -Lyn
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2024, 211
  • [28] Review: Continuous glucose monitoring reduces HbA1c more than self-monitoring in type 1 diabetes
    Burden, A. C. Felix
    ANNALS OF INTERNAL MEDICINE, 2013, 158 (06)
  • [29] The interrelationship of HbA1c and real-time continuous glucose monitoring in children with type 1 diabetes
    Ferenci, Tamas
    Koerner, Anna
    Kovacs, Levente
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2015, 108 (01) : 38 - 44
  • [30] To evaluate the use and clinical effect of intermittently scanned continuous glucose monitoring in adults with type 1 diabetes: Results of a multicentre study
    Moreno-Fernandez, Jesus
    Sastre, Julia
    Pines, Pedro
    Calderon-Vicente, Dulce
    Gargallo, Javier
    Munoz-Rodriguez, Jose-Ramon
    ENDOCRINOLOGIA DIABETES Y NUTRICION, 2023, 70 (04): : 270 - 276