Use of a Needle Probe to Measure the Thermal Conductivity of Electrically Conductive Liquids at High Temperatures

被引:0
|
作者
Ruth, Ryan [1 ]
Merritt, Brian [1 ]
Munro, Troy [1 ]
机构
[1] Brigham Young Univ, Dept Mech Engn, 350 Engn Bldg, Provo, UT 84602 USA
关键词
Molten salts; Specific heat; Thermal conductivity; MOLTEN-SALTS; DIFFUSIVITY; DIRECTIONS; PROGRESS;
D O I
10.1007/s10765-024-03456-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper considers the necessary conditions for using a derivative of a transient hot-wire (termed a needle probe) approach to measure the thermal conductivity of electrically conducting fluids at high temperatures, especially molten halide salts. The focus is on the development of a new theory based on a multi-layer system necessary to ensure electrical isolation of electrical wires from the surrounding fluid. This includes the use of a thin annulus of fluid to minimize convective heat transfer modes within the fluid of interest, which was inspired by the concentric cylinder method. Good measurements require the following considerations: concentricity of the probe and surrounding crucible to ensure a consistent fluid gap, accounting for corrections for deviation of the model at early times, and modeling radiation heat transfer through transparent fluids. Uncertainties are larger than transient hot-wire methods because of the deviations from experimental conditions that can easily match an analytical approximation. An appropriate estimation of the measurement uncertainty can be obtained through careful design of the instrumentation, thorough uncertainty analysis, and limiting the measurements to only the applicable thermal property ranges of the approach. The 1D model used to interpret measured temperature data has been shown to be reliable for thermal conductivity measurements ranging from at least 0.39 W (mK-1) to 0.92 W (mK-1) and for temperatures from 293 K to 1023 K. The approach is used to present thermal conductivity data of the molten salts NaCl-KCl (51-49 mol%) and LiCl-NaCl (72-28 mol%).
引用
收藏
页数:28
相关论文
共 50 条
  • [21] Measurements of the thermal conductivity of reference liquids using a modified transient hot-wire needle probe
    Merritt, B.
    Seneca, M.
    Larson, S.
    Davis, K.
    Munro, T.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 189
  • [22] ABSOLUTE MEASUREMENT OF THE THERMAL-CONDUCTIVITY OF ELECTRICALLY CONDUCTING LIQUIDS
    ASSAEL, MJ
    CHARITIDOU, E
    GEORGIADIS, GP
    WAKEHAM, WA
    BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1988, 92 (05): : 627 - 631
  • [23] Thermal conductivity at high temperatures
    Angell, MF
    PHYSICAL REVIEW, 1911, 33 (05): : 421 - 432
  • [24] Thermal Conductivity of Electrically Conductive Highly Boron Doped Diamond and its Applications at High Frequencies
    Williams, Gruffudd
    Calvo, Julian Anaya
    Faili, Firooz
    Dodson, Joe
    Obeloer, Thomas
    Twitchen, Daniel J.
    PROCEEDINGS OF THE 17TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM 2018), 2018, : 235 - 239
  • [25] The principle to measure thermal conductivity by a new thermal probe method
    Chen, ZS
    Li, C
    Cheng, WL
    Qiu, XH
    Hu, P
    HEAT TRANSFER SCIENCE AND TECHNOLOGY 2000, 2000, : 157 - 162
  • [26] An improved hot probe for measuring thermal conductivity of liquids
    Zhang, HF
    Zhao, G
    Ye, H
    Ge, XS
    Cheng, SX
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (07) : 1430 - 1435
  • [27] A fine needle probe for determining the thermal conductivity of penetrable materials
    Xie, HQ
    Cheng, SX
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (01) : 58 - 62
  • [29] DEVELOPMENT OF A TEST BENCH TO MEASURE THE THERMAL-CONDUCTIVITY OF LIQUIDS
    PASSOS, EF
    GIANOLA, JC
    STORI, C
    REVUE GENERALE DE THERMIQUE, 1985, 24 (287): : 811 - 813
  • [30] ON MEASUREMENT OF THERMAL CONDUCTIVITY AT HIGH TEMPERATURES
    LAUBITZ, MJ