Finite element analysis of biomechanical investigation on diverse internal fixation techniques in oblique lumbar interbody fusion

被引:2
|
作者
Yu, Qi [1 ,2 ]
Zou, Zhuo Lin [3 ]
Lu, Hui Gen [2 ]
Pan, Xue Kang [2 ]
Hu, Xu Qi [2 ]
Shen, Zhong Hai [2 ]
机构
[1] Haining Peoples Hosp, Dept Orthopaed, Jiaxing 314400, Zhejiang, Peoples R China
[2] Jiaxing Univ, Affiliated Hosp 2, Dept Orthopaed, Jiaxing 314001, Zhejiang, Peoples R China
[3] Jiaxing Univ, Hosp Jiaxing 1, Affiliated Hosp, Dept Infect Dis, Jiaxing 314001, Zhejiang, Peoples R China
关键词
Biomechanical study; Lumbar spine; Oblique lumbar interbody fusion; Adjacent segment degeneration; Finite element analysis; SURGERY;
D O I
10.1186/s12891-024-07887-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background To establish a three-dimensional finite element model of the lumbar spine and investigate the impact of different fixation techniques on the biomechanical characteristics of oblique lumbar interbody fusion (OLIF). Methods The study aimed to establish and validate a comprehensive three-dimensional model of the lower lumbar spine (L3-S1) using the finite element method. L4-L5 was selected as the surgical segment, and four distinct OLIF surgical models were constructed: Stand-alone (SA), unilateral cortical bone trajectory screw (UCBT), bilateral cortical bone trajectory screw (BCBT), and bilateral pedicle screw (BPS). The models were underwent a pure moment of 10N center dot m to simulate lumbar extension, flexion, left bending, right bending, left and right rotation movements. Subsequently, the range of motion (ROM), cage stress, and fixation stress were calculated. Results In the L3-L5 segment, the BCBT group showed the most limited range of motion (ROM) under exercise load, indicating superior stability within this group. The ROM and cage stress values were found to be highest in the SA group. In contrast, the cage and internal fixation stress in the BPS group were observed to be lowest (9.91 similar to 53.83MPa, 44.93 similar to 84.85 MPa). With the exception of right bending and right rotation, the UCBT group demonstrated higher levels of internal fixation stress (102.20 similar to 164.62 MPa). Conclusions The study found that OLIF-assisted internal fixation improved segmental stability and reduced cage stress. The BPS group had advantages over the CBT group in preventing endplate damage and reducing the risk of cage subsidence. However, BCBT group has distinct merits in maintaining surgical segment stability, distributing stress load on the spinal motor unit, and reducing the likelihood of adjacent segment degeneration (ASD).
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Biomechanical changes of oblique lumbar interbody fusion with different fixation techniques in degenerative spondylolisthesis lumbar spine: a finite element analysis
    Tao, Er-Xu
    Zhang, Ren-Jie
    Zhang, Bo
    Wang, Jia-Qi
    Zhou, Lu-Ping
    Shen, Cai-Liang
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [2] Biomechanical Evaluation of Oblique Lumbar Interbody Fusion with Various Fixation Options: A Finite Element Analysis
    Song, Chengjie
    Chang, Hengrui
    Zhang, Di
    Zhang, Yingze
    Shi, Mingxin
    Meng, Xianzhong
    ORTHOPAEDIC SURGERY, 2021, 13 (02) : 517 - 529
  • [3] Biomechanical Evaluation of Transforaminal Lumbar Interbody Fusion and Oblique Lumbar Interbody Fusion on the Adjacent Segment: A Finite Element Analysis
    Wang, Bingjin
    Hua, Wenbin
    Ke, Wencan
    Lu, Saideng
    Li, Xingsheng
    Zeng, Xianlin
    Yang, Cao
    WORLD NEUROSURGERY, 2019, 126 : E819 - E824
  • [4] Biomechanical evaluation of different oblique lumbar interbody fusion constructs: a finite element analysis
    Xu, Zhengquan
    Zheng, Qingcong
    Zhang, Liqun
    Chen, Rongsheng
    Li, Zhechen
    Xu, Weihong
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [5] Biomechanical evaluation of different oblique lumbar interbody fusion constructs: a finite element analysis
    Zhengquan Xu
    Qingcong Zheng
    Liqun Zhang
    Rongsheng Chen
    Zhechen Li
    Weihong Xu
    BMC Musculoskeletal Disorders, 25
  • [6] Biomechanical effects of an oblique lumbar interbody fusion combined with posterior augmentation: a finite element analysis
    Shengjia Huang
    Shaoxiong Min
    Suwei Wang
    Anmin Jin
    BMC Musculoskeletal Disorders, 23
  • [7] Biomechanical effects of an oblique lumbar interbody fusion combined with posterior augmentation: a finite element analysis
    Huang, Shengjia
    Min, Shaoxiong
    Wang, Suwei
    Jin, Anmin
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [8] Computational comparison of anterior lumbar interbody fusion and oblique lumbar interbody fusion with various supplementary fixation systems: a finite element analysis
    Ouyang, Pengrong
    Tan, Qinghua
    He, Xijing
    Zhao, Bo
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [9] Computational comparison of anterior lumbar interbody fusion and oblique lumbar interbody fusion with various supplementary fixation systems: a finite element analysis
    Pengrong Ouyang
    Qinghua Tan
    Xijing He
    Bo Zhao
    Journal of Orthopaedic Surgery and Research, 18
  • [10] Biomechanical Evaluation of an Oblique Lateral Locking Plate System for Oblique Lumbar Interbody Fusion: A Finite Element Analysis
    Wang, Yinge
    Wang, Jiajia
    Tu, Sha
    Li, Shuang
    Yi, Jiangpu
    Zhao, Haien
    Qiao, Huanhuan
    Yan, Kang
    Liao, Bo
    WORLD NEUROSURGERY, 2022, 160 : E126 - E141