Experimental investigations into flow boiling heat transfer in ribbed micro-channels with rectangular reentrant cavities

被引:0
|
作者
Yan, Xin [1 ]
Wu, Yue [1 ,2 ]
Zhang, Zitao [1 ,2 ]
He, Kun [2 ]
机构
[1] Institute of Turbomachinery, Xi'an Jiaotong University, Xi'an,710049, China
[2] MOE Key Laboratory of Thermo-Fluid Science and Engineering, Xi'an Jiaotong University, Xi'an,710049, China
关键词
Channel flow - Heat flux - Heat transfer coefficients - Heat transfer performance - Microcavities - Pressure drop - Two phase flow;
D O I
10.1016/j.applthermaleng.2024.125104
中图分类号
学科分类号
摘要
Reentrant cavities are fabricated at the side walls of ribs and bottom walls of grooves to enhance the flow boiling heat transfer in rectangular-ribbed micro-channels. To reveal the geometrical effect of reentrant cavities, two different reentrant cavities, i.e. RRMB-1 (ribbed micro-channel with narrow reentrant cavities) and RRMB-2 (ribbed micro-channel with wide reentrant cavities), are designed and the RM micro-channel (i.e. smooth ribbed micro-channel without reentrant cavities) is manufactured as the baseline case. The flow boiling heat transfer performance in the micro-channels is experimentally investigated at four mass fluxes and a range of heat fluxes. The flow regimes are visualized during the flow boiling process. The influences of reentrant cavities on the heat transfer coefficient, critical heat flux, pressure drop, outlet temperature fluctuation and performance evaluation criterion of three different micro-channels are analyzed and compared. The results showed that the capillary effect in the reentrant cavities results in a 19.5% increase in the heat transfer coefficient, and a 23.4% increase in the critical heat flux for the RRMB-1 at a low mass flux. The pressure drop in the RRMB-1 micro-channel is slightly higher than that in the RM micro-channel in the single-phase region, while it is opposite at the high heat flux condition. The critical heat flux in the RRMB-2 micro-channel is lower than the RRMB-1 micro-channel by 34.5%, but the pressure drop in the RRMB-2 micro-channel is higher than the RRMB-1 micro-channel by 50.3% in the two-phase region. © 2024 Elsevier Ltd
引用
下载
收藏
相关论文
共 50 条
  • [21] Flow and heat transfer characteristics in rough micro-channels
    Li, Z.
    Zhou, T.
    Chen, N.
    Shahzad, M. A.
    Zhang, B.
    Qi, S.
    KERNTECHNIK, 2019, 84 (06) : 520 - 527
  • [22] Modeling heat transfer and liquid flow in micro-channels
    Sabry, MN
    Djebedjian, BO
    Saleh, SH
    Mahgoub, MM
    THERMAL AND MECHANICAL SIMULATION AND EXPERIMENTS IN MICROELECTRONICS AND MICROSYSTEMS, 2004, : 511 - 518
  • [23] Effects of choking on flow and heat transfer in micro-channels
    Lijo, Vincent
    Kim, Heuy Dong
    Setoguchi, Toshiaki
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (04) : 701 - 709
  • [24] The effect of heating direction on flow boiling heat transfer of R134a in micro-channels
    Mingchen Xu
    Li Jia
    Chao Dang
    Qi Peng
    Journal of Thermal Science, 2017, 26 : 166 - 174
  • [25] Investigation of Flow Boiling in Micro-Channels: Heat Transfer, Pressure Drop and Evaluation of Existing Correlations
    Feng, L. L.
    Cao, C. C.
    Zhong, K.
    Jia, H. W.
    JOURNAL OF APPLIED FLUID MECHANICS, 2023, 16 (09) : 1717 - 1728
  • [26] The Effect of Heating Direction on Flow Boiling Heat Transfer of R134a in Micro-channels
    Xu Mingchen
    Jia Li
    Dang Chao
    Peng Qi
    JOURNAL OF THERMAL SCIENCE, 2017, 26 (02) : 166 - 174
  • [27] Experimental investigations on flow boiling performance of reentrant and rectangular microchannels - A comparative study
    Deng, Daxiang
    Wan, Wei
    Tang, Yong
    Wan, Zhenping
    Liang, Dejie
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 82 : 435 - 446
  • [28] Local heat transfer coefficient of flow boiling in microchannels with artificial reentrant cavities
    Kuo, Chih-Jung
    Peles, Yoav
    PROCEEDINGS OF THE ASME/JSME THERMAL ENGINEERING SUMMER HEAT TRANSFER CONFERENCE 2007, VOL 1, 2007, : 119 - 125
  • [29] Numerical investigation of fluid flow and heat transfer under high heat flux using rectangular micro-channels
    Mansoor, Mohammad M.
    Wong, Kok-Cheong
    Siddique, Mansoor
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2012, 39 (02) : 291 - 297
  • [30] Theoretical model for local heat transfer coefficient for annular flow boiling in circular mini/micro-channels
    Kim, Sung-Min
    Mudawar, Issam
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 73 : 731 - 742