Diabetes technology A future without needles: non-invasive glucose measurements in patients with diabetes

被引:0
|
作者
Birkenfeld, Andreas L. [1 ,2 ,3 ,4 ]
Ntziachristos, Vasilis [5 ,6 ,7 ]
机构
[1] German Ctr Diabet Res DZD, Neuherberg, Germany
[2] Eberhard Karls Univ Tubingen, Dept Internal Med Diabetol Endocrinol & Nephrol 4, Tubingen, Germany
[3] Univ Tubingen, Helmholtz Ctr Munich, Inst Diabet Res & Metab Dis, Tubingen, Germany
[4] Kings Coll London, Fac Life Sci & Med, Sch Cardiovasc & Metab Med & Sci, Diabet & Obes Theme, London, England
[5] Tech Univ Munich, Cent Inst Translat Canc Res TranslaTUM, Chair Biol Imaging, Sch Med & Hlth, Munich, Germany
[6] Tech Univ Munich, Sch Computat Informat & Technol, Munich, Germany
[7] Helmholtz Zentrum Munchen, Inst Biol & Med Imaging, Bioengn Ctr, Neuherberg, Germany
关键词
D O I
10.1038/s42255-025-01221-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Optical measurements through the skin are challenging because they usually represent averages across the various layers of skin that are illuminated. A study in Nature Metabolism uses a depth-selective variant of Raman spectroscopy to probe glucose levels specifically in the skin vasculature, and thereby achieves improved glucose sensing in humans.
引用
收藏
页码:247 / 248
页数:2
相关论文
共 50 条
  • [31] Design of a non-invasive blood glucose meter connected to an Android diabetes monitoring application
    Chhiba, Loubna
    Mustapha, Sidqui
    Marzak, Abdelaziz
    4TH INTERNATIONAL CONFERENCE ON SMART CITY APPLICATIONS (SCA' 19), 2019,
  • [32] Exhaled methyl nitrate as a non-invasive markerof blood glucose in type I diabetes
    Novak, B
    Pescatello, A
    Crisos-Tomo, M
    Cooper, D
    Blake, D
    Meinardi, S
    Galassetti, P
    DIABETES, 2005, 54 : A75 - A75
  • [33] Performance of a non-invasive glucose monitoring device for people with prediabetes and type 2 diabetes
    Bahartan, K.
    Gal, A.
    Naidis, E.
    Rozner, A.
    Drexler, A.
    Horman, K.
    Lin, T.
    DIABETOLOGIA, 2017, 60 : S321 - S321
  • [34] Non-invasive glucose extraction by a single polarization rotator system in patients with diabetes (vol 15, 4909, 2024)
    Lo, Yu-lung
    Chen, Yi-sheng
    Wang, Po-yu
    Chang, Ching-min
    Wei, Guan-ting
    Hung, Wei-chun
    BIOMEDICAL OPTICS EXPRESS, 2025, 16 (01): : 111 - 114
  • [35] Circulatory miRNAs as Novel Non-Invasive Biomarkers for the Diagnosis of Coronary Artery Disease in Patients with and Without Diabetes Mellitus
    Kumar, Dinesh
    Narang, Rajiv
    Sreenivas, Vishnubhatla
    Rastogi, Vandana
    Bhatia, Jagriti
    Saluja, Daman
    Srivastava, Kamna
    METABOLISM-CLINICAL AND EXPERIMENTAL, 2020, 104
  • [36] Non-Invasive Blood Glucose Monitoring Technology: A Review
    Tang, Liu
    Chang, Shwu Jen
    Chen, Ching-Jung
    Liu, Jen-Tsai
    SENSORS, 2020, 20 (23) : 1 - 32
  • [37] Non-invasive measurements of myocardial glycolysis and glycogen storage in type 1 diabetes patients using 1-11C-glucose and compartmental modeling
    Herrero, P.
    McGill, J. B.
    Scott, S. W.
    Gunawardena, R.
    Lesniak, D.
    Kisrieva-Ware, Z.
    Peterson, L.
    Gropler, R. J.
    CARDIOVASCULAR DRUGS AND THERAPY, 2006, 20 (06) : 409 - 410
  • [38] Evaluation of a non-invasive, continuous glucose monitoring system in patients with diabetes: results of a glucose clamp study with hypoglycemic and hyperglycemic excursions.
    Caduff, A
    Buschor, S
    Dewarrat, R
    Schrepfer, T
    Nosek, L
    Heise, T
    Kapitza, C
    Heinemann, L
    DIABETOLOGIA, 2003, 46 : A45 - A45
  • [39] Clinical and anatomical features according to invasive and non-invasive methods in CHD patients and diabetes mellitus
    Buzurtanova, Milana
    Mamedov, Mekhman
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (16) : C91 - C92
  • [40] The reliability of non-invasive neurological examinations in people with diabetes
    Sean Lanting
    Peta Craike
    Martin Spink
    Sarah Casey
    Vivienne Chuter
    Journal of Foot and Ankle Research, 6 (Suppl 1)