External microwave applicators for hyperthermia therapy: a review

被引:0
|
作者
Singh, Soni [1 ]
Singh, Surya Pratap [2 ]
Singh, S. P. [3 ]
机构
[1] BRA Bihar Univ, Univ Dept Elect Sci, Muzaffarpur 842001, India
[2] Univ Oklahoma, Hlth Sci Ctr, Oklahoma City, OK 73104 USA
[3] Banaras Hindu Univ, Indian Inst Technol, Dept Elect Engn, Varanasi 221005, India
关键词
Non-invasive applicator; Hyperthermia; Microwave; Cancer; Antenna design; DIRECT-CONTACT APPLICATOR; QUALITY-ASSURANCE GUIDELINES; DIAGONAL HORN APPLICATORS; WATER BOLUS TEMPERATURE; LOADED LENS APPLICATOR; ANTENNA DESIGN; PATCH ANTENNA; LOCAL HYPERTHERMIA; SAR DISTRIBUTIONS; PHASED-ARRAYS;
D O I
10.1007/s42452-025-06621-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The continuous evolution of technology leads to increased application in health care. In recent years various efforts have been made in the treatment of cancer, including hyperthermia, but cancer remains a research subject worldwide. However, microwave hyperthermia has been an active area of research due to its advantages of focused heating of cancerous tissue while minimally affecting normal tissue. External hyperthermia applicators are designed and optimized to non-invasively couple microwave energy to the human body or other biological systems to kill cancerous cells and enhance the efficacy of radiation therapy and chemotherapy. These applicators need to meet various characteristics to make them suitable for the said applications, the most essential of which are applicator size, minimum leakage radiation, focused near field, and deep penetration. Many works are available in the literature for the hyperthermia applicator design, but none explores the large number of external applicators for hyperthermia treatment of cancer. This paper presents an extensive exploration of the development of external applicators (i.e., waveguide and planar) with a detailed investigation of the antenna element performance available for hyperthermia applications. This study attempts to identify the physiological and biological factors that affect the efficacy of efficient hyperthermia applicator design.
引用
收藏
页数:25
相关论文
共 50 条
  • [31] Conformal microwave array (CMA) applicators for hyperthermia of diffuse chest wall recurrence
    Stauffer, Paul R.
    Maccarini, Paolo
    Arunachalam, Kavitha
    Craciunescu, Oana
    Diederich, Chris
    Juang, Titania
    Rossetto, Francesca
    Schlorff, Jaime
    Milligan, Andrew
    Hsu, Joe
    Sneed, Penny
    Vujaskovic, Zeljko
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2010, 26 (07) : 686 - 698
  • [32] EXPERIMENTAL AND THEORETICAL-ANALYSIS OF PLANAR APPLICATORS FOR MICROWAVE HYPERTHERMIA AT 434 MHZ
    MICHEL, C
    DUBOIS, L
    CRESSON, PY
    CHIVE, M
    PRIBETICH, J
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 1995, 9 (05) : 283 - 289
  • [33] THEORETICAL AND EXPERIMENTAL-ANALYSIS OF AIR COOLING FOR INTRACAVITARY MICROWAVE HYPERTHERMIA APPLICATORS
    YEH, MM
    TREMBLY, BS
    DOUPLE, EB
    RYAN, TP
    HOOPES, PJ
    JONSSON, E
    HEANEY, JA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (09) : 874 - 882
  • [34] Modeling of various kinds of applicators used for microwave hyperthermia based on the FDTD method
    Camart, JC
    Despretz, D
    Chive, M
    Pribetich, J
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1996, 44 (10) : 1811 - 1818
  • [35] Analytical modeling of insulated dipole applicators for interstitial hyperthermia: A review
    Sagnard, Florence
    RADIOENGINEERING, 2007, 16 (02) : 20 - 27
  • [36] COMBINING SDA AND FDTD METHODS FOR THE MODELING OF PLANAR APPLICATORS USED IN MICROWAVE HYPERTHERMIA
    DUHAMEL, F
    DUBOIS, L
    CHIVE, M
    PRIBETICH, J
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 1994, 7 (05) : 228 - 232
  • [37] Planar applicators for local hyperthermia
    Safarik, Jakub
    Rychlik, Ondrej
    PROCEEDINGS OF 19TH INTERNATIONAL CONFERENCE RADIOELEKTRONIKA 2009, 2009, : 349 - 352
  • [38] Novel Microwave Applicators for Thermal Therapy, Ablation, and Hemostasis
    Ryan, Thomas P.
    Clegg, Peter
    ENERGY-BASED TREATMENT OF TISSUE AND ASSESSMENT V, 2009, 7181
  • [39] THERMAL FIELD SIZE VARIATION WITH DEPTH IN TISSUE FOR EXTERNAL MICROWAVE APPLICATORS
    SANDHU, TS
    KOLOZSVARY, A
    MEDICAL PHYSICS, 1982, 9 (04) : 630 - 630
  • [40] Theoretical modelling of thermal response in the tissue, made by contact flexible applicators at microwave hyperthermia
    Pavlysh, VA
    Kostjuk, IV
    Stasevich, SP
    11TH INTERNATIONAL CONFERENCE MICROWAVE & TELECOMMUNICATION TECHNOLOGY, CONFERENCE PROCEEDINGS, 2001, : 90 - 91