Influence of view factors on outdoor thermal comfort of residential areas in hot-humid regions

被引:0
|
作者
Li Li [1 ]
Jiayi Hong [1 ]
Mingtao Ma [1 ]
Chengliang Fan [1 ]
Xiu Xiong [2 ]
Yue Pang [1 ]
机构
[1] Guangzhou University,School of Architecture and Urban Planning
[2] Guangdong Heavy Industry Architectural Design Institute Co. LTD,undefined
关键词
View factors; Outdoor thermal comfort; Outdoor thermal environment; PET; Hot-humid areas;
D O I
10.1007/s00484-024-02810-6
中图分类号
学科分类号
摘要
Sky View Factor (SVF) is commonly used to describe the impact of urban geometry on the urban thermal environment. Shading effects from plants and buildings also exert a considerable influence. To investigate the influence of view factors on outdoor thermal comfort in residential areas, we employed the Physiological Equivalent Temperature (PET) and view factors (SVF, TVF, BVF) as indicators to determine outdoor thermal comfort and the quantity of shaded spaces. Thermal measurements collected from 13 points in Guangzhou, China, Our findings revealed that high TVF points exhibited more stable air temperature throughout the daytime, with average temperature differentials ranging 0.4–1.9 °C lower than other points. Air temperature demonstrated a positive correlation with SVF (R2 = 0.53), while exhibiting a negative correlation with TVF (R2 = 0.45). Additionally, shading provided by plants and buildings manifests heterogeneity. At similar SVF levels, points predominantly shaded by plants (TVF > BVF) showcased lower Mean Radiant Temperature (MRT) and PET compared to points shaded mainly by buildings (BVF > TVF). The maximum reduction in air temperature and PET reached 1.1 °C and 1.2 °C, respectively. BVF exerted greater influence earlier in the morning, as solar altitude angle rises, the average thermal parameters of sites with BVF > TVF escalated rapidly until eventually surpassing sites with TVF > BVF. Last, superior thermal conditions were only ensured under high shading conditions. When the effective shading ratio of plants and buildings diminished (SVF > 0.3), the microclimate of measurement points might be impacted by the long-wave radiation from the underlying surface.
引用
下载
收藏
页码:261 / 274
页数:13
相关论文
共 50 条
  • [21] INVESTIGATION OF OUTDOOR THERMAL COMFORT IN HOT AND HUMID ENVIRONMENT
    Cheng, Ming-Jen
    Lo, Jen-Hao
    Hwang, Ruey-Lung
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1086 - 1094
  • [22] Impact of coupled heat and moisture transfer on indoor comfort and energy demand for residential buildings in hot-humid regions
    Xia, Dawei
    Zhong, Zhengnan
    Huang, Yu
    Zou, Yukai
    Lou, Siwei
    Zhan, Qiaosheng
    Guo, Jialiang
    Yang, Jiahao
    Guo, Tongye
    ENERGY AND BUILDINGS, 2023, 288
  • [23] Thermal comfort in interior and semi-open spaces of rural folk houses in hot-humid areas
    Zhang, Zhongjun
    Zhang, Yufeng
    Jin, Ling
    BUILDING AND ENVIRONMENT, 2018, 128 : 336 - 347
  • [24] Passive design strategies to improve student thermal comfort: A field study in semi-outdoor spaces of academic buildings in hot-humid areas
    Zhao, Yang
    Yang, Jiahao
    Fang, Zhaosong
    Zhang, Xiang
    Guo, Tongye
    Li, Yuankui
    URBAN CLIMATE, 2024, 53
  • [25] Adaptive thermal comfort model for educational buildings in a hot-humid climate
    Lopez-Perez, L. A.
    Flores-Prieto, J. J.
    Rios-Rojas, C.
    BUILDING AND ENVIRONMENT, 2019, 150 : 181 - 194
  • [26] Thermal comfort in naturally ventilated buildings in hot-humid area of China
    Zhang, Yufeng
    Wang, Jinyong
    Chen, Huimei
    Zhang, Jun
    Meng, Qinglin
    BUILDING AND ENVIRONMENT, 2010, 45 (11) : 2562 - 2570
  • [27] Influence of space properties of enclosed patio on thermal performance in hot-humid areas of China
    Sun, Qianqian
    Fan, Zhengyu
    Bai, Lujian
    AIN SHAMS ENGINEERING JOURNAL, 2024, 15 (02)
  • [28] OCCUPANT BEHAVIOR ADAPTATION FOR THERMAL COMFORT IN HOT-HUMID CLIMATE OF CHINA
    Zheng, Y.
    Liu, W. W.
    Deng, Q. H.
    7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 263 - 268
  • [29] Occupant behavior adaptation for thermal comfort in hot-humid climate of China
    School of Energy Science and Engineering, Central South University, Changsha 410083, China
    Int. Symp. Heat., Vent. Air Cond. - Proc. ISHVAC, (263-268):
  • [30] Environmental and human factors influencing thermal comfort of office occupants in hot-humid and hot-arid climates
    Erlandson, T
    Cena, K
    de Dear, R
    Havenith, G
    ERGONOMICS, 2003, 46 (06) : 616 - 628