Non-contact lensless holographic reconstruction of diffractive intraocular lenses profiles

被引:0
|
作者
Vila-Andres, Rosa [1 ]
Martinez-Espert, Anabel [1 ]
Furlan, Walter D. [1 ]
Esteve-Taboada, Jose J. [1 ]
Mico, Vicente [1 ]
机构
[1] Univ Valencia, Fac Phys, Dept Opt & Optometry & Vis Sci, Burjassot, Spain
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
DIGITAL HOLOGRAPHY; PHASE RETRIEVAL; ILLUMINATION; PERFORMANCE; DESIGN; MAGNIFICATION; ABERRATIONS; MICROSCOPY; IMAGE;
D O I
10.1038/s41598-024-84363-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A lensless compact arrangement based on digital in-line holography under Gabor's regime is proposed as a novel contactless method to assess the profile of multifocal intraocular lenses (MIOLs) which are conformed by several diffractive rings. Diffractive MIOLs are a widely adopted ophthalmologic option for the correction of presbyopia in patients undergoing cataract surgery. The MIOL optical design might introduce non-negligible optical performance differences between lenses as well as the introduction of undesirable photic phenomena (such as halos and glare) affecting the vision of users. Therefore, the customized topographic control of each manufactured MIOL model, along with the advancement of optical simulation routines, is increasingly necessary to provide users with optimized performance of these implanted optics, as well as predictable and realistic expectations of their future vision with these solutions. In this manuscript, experimental results of the reconstruction of different smooth and highly edged diffractive profiles from a pair of commercially available MIOLs are presented. Besides, a study evaluating the convergence and robustness of the proposed iterative phase-retrieval routine based on a modified classical Gerchberg-Saxton algorithm is performed. These results provide experimental validation of the proposed technique for accurately measuring the optical profiles of MIOLs.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Optical nano-imaging via microsphere compound lenses working in non-contact mode
    Wu, Guangxing
    Hong, Minghui
    OPTICS EXPRESS, 2021, 29 (15) : 23073 - 23082
  • [42] NON-CONTACT MEASUREMENT SYSTEM OF FREEFORM SURFACE AND NURBS RECONSTRUCTION OF MEASUREMENT POINTS
    Li Jian Wang Wen Chen Zichen Institute of Advanced Manufacturing Engineering
    Chinese Journal of Mechanical Engineering(English Edition), 2002, (04) : 366 - 371
  • [43] Complications and compliance in professionally-managed and self-managed contact lenses compared with non-contact lens wearers
    Gantz, Liat
    Weissman, Barry A.
    Ifrah, Reut
    PLOS ONE, 2024, 19 (09):
  • [44] Spatial Reconstruction of Soil Moisture Content using Non-Contact Thermoacoustic Imaging
    Fitzpatrick, Aidan
    Singhvi, Ajay
    Arbabian, Amin
    2020 IEEE SENSORS, 2020,
  • [45] Tidal Volume Measurement Through Non-Contact Doppler Radar With DC Reconstruction
    Massagram, Wansuree
    Hafner, Noah
    Lubecke, Victor
    Boric-Lubecke, Olga
    IEEE SENSORS JOURNAL, 2013, 13 (09) : 3397 - 3404
  • [46] Influence of lens material and intra-ocular pressure on the outcome of non-contact tonometry over soft contact lenses
    Patel, Sudi
    Stevenson, Graeme
    CONTACT LENS & ANTERIOR EYE, 2009, 32 (02): : 68 - 72
  • [47] Influence of corneal thickness on comparative intraocular pressure measurements with goldmann and non-contact tonometers in keratoconus
    Silih, MS
    Hawlina, M
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2003, 220 (12) : 843 - 847
  • [48] Non-contact tonometry using Corvis ST: analysis of corneal vibrations and their relation with intraocular pressure
    Boszczyk, Agnieszka
    Kasprzak, Henryk
    Siedlecki, Damian
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2019, 36 (04) : B28 - B34
  • [49] Intraocular pressure measurement with Corvis ST in comparison with applanation tonometry and Tomey non-contact tonometry
    Luebke, Jan
    Bryniok, L.
    Neuburger, M.
    Jordan, J. F.
    Boehringer, D.
    Reinhard, T.
    Wecker, T.
    Anton, A.
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (11) : 2517 - 2521
  • [50] Intraocular pressure measurement with Corvis ST in comparison with applanation tonometry and Tomey non-contact tonometry
    Jan Luebke
    L. Bryniok
    M. Neuburger
    J. F. Jordan
    D. Boehringer
    T. Reinhard
    T. Wecker
    A. Anton
    International Ophthalmology, 2019, 39 : 2517 - 2521