Non-contact lensless holographic reconstruction of diffractive intraocular lenses profiles

被引:0
|
作者
Vila-Andres, Rosa [1 ]
Martinez-Espert, Anabel [1 ]
Furlan, Walter D. [1 ]
Esteve-Taboada, Jose J. [1 ]
Mico, Vicente [1 ]
机构
[1] Univ Valencia, Fac Phys, Dept Opt & Optometry & Vis Sci, Burjassot, Spain
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
DIGITAL HOLOGRAPHY; PHASE RETRIEVAL; ILLUMINATION; PERFORMANCE; DESIGN; MAGNIFICATION; ABERRATIONS; MICROSCOPY; IMAGE;
D O I
10.1038/s41598-024-84363-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A lensless compact arrangement based on digital in-line holography under Gabor's regime is proposed as a novel contactless method to assess the profile of multifocal intraocular lenses (MIOLs) which are conformed by several diffractive rings. Diffractive MIOLs are a widely adopted ophthalmologic option for the correction of presbyopia in patients undergoing cataract surgery. The MIOL optical design might introduce non-negligible optical performance differences between lenses as well as the introduction of undesirable photic phenomena (such as halos and glare) affecting the vision of users. Therefore, the customized topographic control of each manufactured MIOL model, along with the advancement of optical simulation routines, is increasingly necessary to provide users with optimized performance of these implanted optics, as well as predictable and realistic expectations of their future vision with these solutions. In this manuscript, experimental results of the reconstruction of different smooth and highly edged diffractive profiles from a pair of commercially available MIOLs are presented. Besides, a study evaluating the convergence and robustness of the proposed iterative phase-retrieval routine based on a modified classical Gerchberg-Saxton algorithm is performed. These results provide experimental validation of the proposed technique for accurately measuring the optical profiles of MIOLs.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Eeffect of soft contact lenses on the measurements of intraocular pressure with non-contact pneumotonometry
    Schollmayer, P
    Hawlina, M
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2003, 220 (12) : 840 - 842
  • [2] The impact of silicone hydrogel contact lenses on the measurement of intraocular pressure using non-contact tonometry
    Pesic, Snezana
    Jovanovic, Svetlana
    Mitrasevic, Milos
    Vuletic, Biljana
    Jovanovic, Milena
    Jovanovic, Zorica
    VOJNOSANITETSKI PREGLED, 2017, 74 (08) : 763 - 766
  • [3] Advancements in non-contact metrology of asphere and diffractive optics
    DeFisher, Scott
    OPTIFAB 2017, 2017, 10448
  • [4] Ocular surface displacement with and without contact lenses during non-contact tonometry
    Rimayanti, Ulfah
    Kiuchi, Yoshiaki
    Uemura, Shohei
    Takenaka, Joji
    Mochizuki, Hideki
    Kaneko, Makoto
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [5] Ocular Surface Displacement with and without Contact Lenses during Non-Contact Tonometry
    Rimayanti, Ulfah
    Kiuchi, Yoshiaki
    Uemura, Shohei
    Takenaka, Joji
    Mochizuki, Hideki
    Kaneko, Makoto
    PLOS ONE, 2014, 9 (04):
  • [6] Fogging of Non-Contact Viewing Lenses During Vitreoretinal Surgery
    Kreps, Elke O.
    Lemm, Joanna M.
    Ruagh, Essam A.
    Ramkissoon, Yashin D.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (12): : 2428 - 2429
  • [7] Analysis of differences in intraocular pressure evaluation performed with contact and non-contact devices
    Michele Lanza
    Michele Rinaldi
    Ugo Antonello Gironi Carnevale
    Silvio di Staso
    Mario Bifani Sconocchia
    Ciro Costagliola
    BMC Ophthalmology, 18
  • [8] Non-contact dimensional measurement system using holographic scanning
    Sagan, SF
    Rosso, RS
    Rowe, DM
    OPTICAL SCANNING SYSTEMS: DESIGN AND APPLICATIONS, 1997, 3131 : 224 - 231
  • [9] Holographic camera for non-contact measurement of nanoscale surface heights
    Wang, Hui
    Omidi, Parsa
    Carson, Jeffrey J. L.
    Diop, Mamadou
    PRACTICAL HOLOGRAPHY XXXIII: DISPLAYS, MATERIALS, AND APPLICATIONS, 2019, 10944
  • [10] Analysis of differences in intraocular pressure evaluation performed with contact and non-contact devices
    Lanza, Michele
    Rinaldi, Michele
    Carnevale, Ugo Antonello Gironi
    di Staso, Silvio
    Sconocchia, Mario Bifani
    Costagliola, Ciro
    BMC OPHTHALMOLOGY, 2018, 18