Wear factor comparison between single and dual mobility cup in total hip arthroplasty

被引:0
|
作者
Louis Riglet [1 ]
Laure-Lise Gras [2 ]
Anthony Viste [3 ]
Florent Moissenet [3 ]
Xavier Gasparutto [4 ]
Michel-Henri Fessy [5 ]
Didier Hannouche [6 ]
Stéphane Armand [5 ]
Raphaël Dumas [3 ]
机构
[1] CHU Dijon-Bourgogne,Plateforme d’Investigation Technologique
[2] Centre d’Investigation Clinique,INSERM, CIC 1432, Module Plurithématique
[3] Module Plurithématique,LBMC UMR_T9406
[4] Plateforme d’Investigation Technologique,Service de Chirurgie Orthopédique et Traumatologique
[5] Univ Gustave Eiffel,Kinesiology Laboratory
[6] Univ Claude Bernard Lyon 1,Biomechanics Laboratory
[7] Hospices Civils de Lyon,Division of Orthopaedic Surgery and Musculoskeletal Trauma Care, Surgery Department
[8] Geneva University Hospitals and University of Geneva,undefined
[9] Geneva University Hospitals and University of Geneva,undefined
[10] Geneva University Hospitals and University of Geneva,undefined
关键词
Wear estimation; Total hip arthroplasty; Dual mobility cup; Musculoskeletal modelling; Clinical gait analysis;
D O I
10.1007/s11044-024-10031-3
中图分类号
学科分类号
摘要
The dual mobility cup (DMC) was developed to decrease wear, increase stability, and restore patients’ hip range of motion compared to the traditional single mobility cup (SMC) in total hip arthroplasty (THA). A rejuvenation of the THA population is increasing the risk of wear, and more personalised follow-up of patients is required. The aim of this study was to estimate DMC-THA wear during daily life activities based on 3D motion capture data. Using a musculoskeletal and a stem–liner contact model, a wear factor was computed for 16 participants with SMC-THA and compared to virtual DMC-THA. The force–velocity factor was estimated for slow, self-selected, and fast gait, as well as sit-to-stand and stand-to-sit activities. A significantly lower factor was found for DMC-THA than for SMC-THA during gait at the different speeds and during sit-to-stand. In the stand-to-sit task, the potential advantage of DMC-THA was not demonstrated, likely because the liner kinematics was simulated during intervals in the activity when hip contact force and sliding velocity were high. This study suggests the potential lower risk of wear of the DMC-THA, based on 3D motion capture data and multibody dynamics simulations. It also showed that an in vivo risk of wear can be estimated to help stratifying patients.
引用
收藏
页码:397 / 412
页数:15
相关论文
共 50 条
  • [1] Comparison of dual-mobility cup and unipolar cup for prevention of dislocation after revision total hip arthroplasty
    Gonzalez, Amanda Inez
    Bartolone, Placido
    Lubbeke, Anne
    Dupuis Lozeron, Elise
    Peter, Robin
    Hoffmeyer, Pierre
    Christofilopoulos, Panayiotis
    Acta Orthopaedica, 2017, 88 (01) : 18 - 23
  • [2] Cementless dual-mobility cup in total hip arthroplasty revision
    Jean Louis Prudhon
    François Steffann
    André Ferreira
    Régis Verdier
    Thierry Aslanian
    Jacques Caton
    International Orthopaedics, 2014, 38 : 2463 - 2468
  • [3] Dual mobility acetabular cup for total hip arthroplasty: use with caution
    Vahedi, Hamed
    Makhdom, Asim M.
    Parvizi, Javad
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (03) : 237 - 243
  • [4] Cementless dual-mobility cup in total hip arthroplasty revision
    Prudhon, Jean Louis
    Steffann, Francois
    Ferreira, Andre
    Verdier, Regis
    Aslanian, Thierry
    Caton, Jacques
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (12) : 2463 - 2468
  • [5] The Lefevre retentive cup compared with the dual mobility cup in total hip arthroplasty revision for dislocation
    Labban, Julien
    Letissier, Hoel
    Mertl, Patrice
    Lefevre, Christian
    Migaud, Henri
    Clave, Arnaud
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (09) : 1661 - 1667
  • [6] The Avantage ® dual mobility cup in primary total hip arthroplasty: A registry study
    Castiello, E.
    Bruschi, A.
    Bordini, B.
    De Gaetano, F.
    Tigani, D.
    JOURNAL OF ORTHOPAEDICS, 2024, 56 : 98 - 102
  • [7] ACETABULAR CUP WEAR IN TOTAL HIP-ARTHROPLASTY
    RIMNAC, CM
    WILSON, PD
    FUCHS, MD
    WRIGHT, TM
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1988, 19 (03) : 631 - 636
  • [8] Dual Mobility in Total Hip Arthroplasty
    Clair, Andrew J.
    Buchalter, Daniel B.
    Kugelman, David N.
    Deshmukh, Ajit J.
    Aggarwal, Vinay K.
    Rozell, Joshua C.
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2022, 80 (01): : 4 - 10
  • [9] Dual Mobility in Total Hip Arthroplasty
    Plummer, Darren R.
    Haughom, Bryan D.
    Della Valle, Craig J.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2014, 45 (01) : 1 - +
  • [10] The Lefèvre retentive cup compared with the dual mobility cup in total hip arthroplasty revision for dislocation
    Julien Labban
    Hoël Letissier
    Patrice Mertl
    Christian Lefèvre
    Henri Migaud
    Arnaud Clavé
    International Orthopaedics, 2020, 44 : 1661 - 1667