Comparison of dual-mobility cup and unipolar cup for prevention of dislocation after revision total hip arthroplasty

被引:36
|
作者
Gonzalez, Amanda Inez [1 ]
Bartolone, Placido [1 ]
Lubbeke, Anne [1 ]
Dupuis Lozeron, Elise [2 ]
Peter, Robin [1 ]
Hoffmeyer, Pierre [1 ]
Christofilopoulos, Panayiotis [1 ]
机构
[1] Univ Hosp Geneva, Div Orthopaed & Trauma Surg, Geneva, Switzerland
[2] Univ Hosp Geneva, Div Epidemiol, Geneva, Switzerland
关键词
FOLLOW-UP; REPLACEMENT; RISK; WEAR; INSTABILITY; BEARINGS; REGISTER; RATES;
D O I
10.1080/17453674.2016.1255482
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose - Revision total hip arthroplasty (THA) is associated with higher dislocation rates than primary THA. We compared the risk of dislocation within 6 months and all-cause re-revision during the whole study period using either the dual-mobility cup or the unipolar cup. Methods - We used a prospective hospital registry-based cohort including all total and cup-only revision THAs performed between 2003 and 2013. The cups used were either dual-mobility or unipolar; the choice was made according to the preference of the surgeon. 316 revision THAs were included. The mean age of the cohort was 69 (25-98) years and 160 THAs (51%) were performed in women. The dual-mobility group (group 1) included 150 THAs (48%) and the mean length of follow-up was 31 (0-128) months. The unipolar group (group 2) included 166 THAs (53%) and the mean length of follow-up was 52 (0-136) months. Results - The incidence of dislocation within 6 months was significantly lower with the dual-mobility cup than with the unipolar cup (2.7% vs. 7.8%). The unadjusted risk ratio (RR) was 0.34 (95% CI: 0.11-1.02) and the adjusted RR was 0.28 (95% CI: 0.09-0.87). The number of patients needed to treat with a dual-mobility cup in order to prevent 1 case of dislocation was 19. The unadjusted incidence rate ratio for all-cause re-revision in the dual-mobility group compared to the unipolar group was 0.6 (95% CI: 0.3-1.4). Interpretation - Use of a dual-mobility rather than a unipolar cup in revision THA reduced the risk of dislocation within 6 months.
引用
收藏
页码:18 / 23
页数:6
相关论文
共 50 条
  • [1] Cementless dual-mobility cup in total hip arthroplasty revision
    Jean Louis Prudhon
    François Steffann
    André Ferreira
    Régis Verdier
    Thierry Aslanian
    Jacques Caton
    [J]. International Orthopaedics, 2014, 38 : 2463 - 2468
  • [2] Cementless dual-mobility cup in total hip arthroplasty revision
    Prudhon, Jean Louis
    Steffann, Francois
    Ferreira, Andre
    Verdier, Regis
    Aslanian, Thierry
    Caton, Jacques
    [J]. INTERNATIONAL ORTHOPAEDICS, 2014, 38 (12) : 2463 - 2468
  • [3] The Lefevre retentive cup compared with the dual mobility cup in total hip arthroplasty revision for dislocation
    Labban, Julien
    Letissier, Hoel
    Mertl, Patrice
    Lefevre, Christian
    Migaud, Henri
    Clave, Arnaud
    [J]. INTERNATIONAL ORTHOPAEDICS, 2020, 44 (09) : 1661 - 1667
  • [4] The Lefèvre retentive cup compared with the dual mobility cup in total hip arthroplasty revision for dislocation
    Julien Labban
    Hoël Letissier
    Patrice Mertl
    Christian Lefèvre
    Henri Migaud
    Arnaud Clavé
    [J]. International Orthopaedics, 2020, 44 : 1661 - 1667
  • [5] Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty
    Mohammed R.
    Hayward K.
    Mulay S.
    Bindi F.
    Wallace M.
    [J]. Journal of Orthopaedics and Traumatology, 2015, 16 (1) : 9 - 13
  • [6] Dual mobility cup in revision total hip arthroplasty: Dislocation rate and survival after 5 years
    Simian, E.
    Chatellard, R.
    Druon, J.
    Berhouet, J.
    Rosset, P.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (05) : 577 - 581
  • [7] Is Cemented Dual-Mobility Cup a Reliable Option in Primary and Revision Total Hip Arthroplasty: A Systematic Review
    Ciolli, Gianluca
    Mesnard, Guillaume
    Deroche, Etienne
    Gunst, Stanislas
    Batailler, Cecile
    Servien, Elvire
    Lustig, Sebastien
    [J]. JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (01):
  • [8] Reduced Revision Risk for Dual-Mobility Cup in Total Hip Replacement Due to Hip Fracture
    Jobory, Ammar
    Karrholm, Johan
    Overgaard, Soren
    Pedersen, Alma Becic
    Hallan, Geir
    Gjertsen, Jan-Erik
    Makela, Keijo
    Rogmark, Cecilia
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (14): : 1278 - 1285
  • [9] In total hip arthroplasty via the direct anterior approach, a dual-mobility cup prevents dislocation as effectively in hip fracture as in osteoarthritis
    Yasuhiro Homma
    Tomonori Baba
    Yu Ozaki
    Taiji Watari
    Hideo Kobayashi
    Hironori Ochi
    Mikio Matsumoto
    Kazuo Kaneko
    [J]. International Orthopaedics, 2017, 41 : 491 - 497
  • [10] In total hip arthroplasty via the direct anterior approach, a dual-mobility cup prevents dislocation as effectively in hip fracture as in osteoarthritis
    Homma, Yasuhiro
    Baba, Tomonori
    Ozaki, Yu
    Watari, Taiji
    Kobayashi, Hideo
    Ochi, Hironori
    Matsumoto, Mikio
    Kaneko, Kazuo
    [J]. INTERNATIONAL ORTHOPAEDICS, 2017, 41 (03) : 491 - 497