Real-time monitoring of bioelectrical impedance for minimizing tissue carbonization in microwave ablation of porcine liver

被引:0
|
作者
Zhang, Xiao [1 ,3 ]
Wei, Wei [1 ,3 ]
Qian, Lu [2 ,3 ]
Yao, Liuye [2 ,3 ]
Jin, Xiaofei [2 ,3 ]
Xing, Lidong [1 ,3 ]
Qian, Zhiyu [2 ,3 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Dept Elect Engn, Nanjing 211106, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Dept Biomed Engn, Nanjing 211106, Peoples R China
[3] Nanjing Univ Aeronaut & Astronaut, Key Lab Multimodal Brain Comp Precis Drive, Ind & Informat Technol Minist, Nanjing 211106, Peoples R China
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
基金
中国国家自然科学基金;
关键词
Microwave ablation; Carbonization; Electrical impedance; Temperature; THERMAL ABLATION; FIBER; MODEL;
D O I
10.1038/s41598-024-80725-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The charring tissue generated by the high temperature during microwave ablation can affect the therapeutic effect, such as limiting the volume of the coagulation zone and causing rejection. This paper aimed to prevent tissue carbonization while delivering an appropriate thermal dose for effective ablations by employing a treatment protocol with real-time bioelectrical impedance monitoring. Firstly, the current field response under different microwave ablation statuses is analyzed based on finite element simulation. Next, the change of impedance measured by the electrodes is correlated with the physical state of the ablated tissue, and a microwave ablation carbonization control protocol based on real-time electrical impedance monitoring was established. The finite element simulation results show that the dielectric properties of biological tissues changed dynamically during the ablation process. Finally, the relative change rule of the electrical impedance magnitude of the ex vivo porcine liver throughout the entire MWA process and the reduction of the central zone carbonization were obtained by the MWA experiment. Charring tissue was eliminated without water cooling at 40 W and significantly reduced at 50 W and 60 W. The carbonization during MWA can be reduced according to the changes in tissue electrical impedance to optimize microwave thermal ablation efficacy.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A Real-time Circuit Topology for Battery Impedance Monitoring
    Lashway, Christopher R.
    Constant, Geraldson
    Theogene, Junior
    Mohammed, Osama
    SOUTHEASTCON 2016, 2016,
  • [22] Dual-Applicator MR Imaging-Guided Microwave Ablation with Real-Time MR Thermometry: Phantom and Porcine Tissue Model Experiments
    Ren, Liqiang
    Woodrum, David A.
    Gorny, Krzysztof R.
    Felmlee, Joel P.
    Favazza, Christopher P.
    Thompson, Scott M.
    Lu, Aiming
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 34 (01) : 46 - 53.e4
  • [23] Diagnostics and real-time monitoring of pulsed laser ablation
    Hong, MH
    Lu, YF
    Chong, TC
    SECOND INTERNATIONAL SYMPOSIUM ON LASER PRECISION MICROFABRICATION, 2002, 4426 : 51 - 54
  • [24] An Economic Real-Time Microwave Plasma Impedance Measurement Method
    Zhang, Chaoyang
    Lu, Dun
    Hu, Shijie
    Chen, Chi
    Fu, Wenjie
    Han, Meng
    Li, Xiaoyun
    Yan, Yang
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2021, 49 (11) : 3503 - 3508
  • [25] Real-Time and Delayed Imaging of Tissue and Effects of Prostate Tissue Ablation
    Tayebi, Shima
    Verma, Sadhna
    Sidana, Abhinav
    CURRENT UROLOGY REPORTS, 2023, 24 (10) : 477 - 489
  • [26] Real-Time and Delayed Imaging of Tissue and Effects of Prostate Tissue Ablation
    Shima Tayebi
    Sadhna Verma
    Abhinav Sidana
    Current Urology Reports, 2023, 24 : 477 - 489
  • [27] Real-Time Monitoring of Thermal Phenomena during Femtosecond Ablation of Bone Tissue for Process Control
    Al-Bourgol, Samy
    Machinet, Guillaume
    Bakkali, Aboubakr
    Faucon, Marc
    Gemini, Laura
    BIOENGINEERING-BASEL, 2024, 11 (04):
  • [28] Real-time extraction of tissue impedance model parameters for electrical impedance spectrometer
    Kun, S.
    Ristic, B.
    Peura, R.A.
    Dunn, R.M.
    Medical and Biological Engineering and Computing, 1999, 37 (04): : 428 - 432
  • [29] Real-time extraction of tissue impedance model parameters for electrical impedance spectrometer
    S. Kun
    B. Ristic
    R. A. Peura
    R. M. Dunn
    Medical & Biological Engineering & Computing, 1999, 37 : 428 - 432
  • [30] Real-time extraction of tissue impedance model parameters for electrical impedance spectrometer
    Kun, S
    Ristic, B
    Peura, RA
    Dunn, RM
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (04) : 428 - 432