Preliminary results of feasibility, safety and efficacy of robotic assisted laparoscopic pyeloplasty with the SHURUI single-port robotic surgical platform in children

被引:0
|
作者
Huang, Yangyue [1 ]
Zhang, Weiping [1 ]
Song, Hongcheng [1 ]
He, Yuzhu [1 ]
Lin, Defu [1 ]
Li, Minglei [1 ]
Li, Ning [1 ]
Liu, Chao [1 ]
Han, Wenwen [1 ]
机构
[1] Capital Med Univ, Beijing Childrens Hosp, Natl Ctr Childrens Hlth, Dept Pediat Urol, 56 Nan Li Shi St, Beijing 100045, Peoples R China
关键词
Robotic assisted laparoscopic pyeloplasty; Ureteropelvic junction obstruction; The SHURUI single port; SURGERY; SITE; SYSTEM;
D O I
10.1007/s11701-025-02294-5
中图分类号
R61 [外科手术学];
学科分类号
摘要
This study aims to evaluate the feasibility, safety and efficacy of robotic assisted laparoscopic pyeloplasty (RALP) with the novel SHURUI single-port (SR-SP) robotic surgical platform in children. Between November 2023 and April 2024, 20 pediatric patients diagnosed with ureteropelvic junction obstruction (UPJO) underwent transperitoneal RALP with the SR-SP surgical platform. Baseline characteristics, perioperative parameters and follow-up data were collected and analyzed. All surgical procedures were successfully performed without conversion to open or laparoscopic surgery. The median docking time, console time, and operative time were 3.5 min (range 3.5-6.0), 144.5 min (range 88.0-290.0), and 221.5 min (range 136.0-450.0), respectively. The median estimated blood loss was 5 ml (range 2-20) and the median length of hospital stays was 6 days (range 4-24). Through trans-umbilical incision, RALP was feasible in patients with a height of no less than 114 cm. The minimum incision length was 2 cm. No intraoperative complication was identified. Two cases were identified with the Clavien-Dindo Grade II postoperative complications and one with the Clavien-Dindo Grade III complications. The surgical success rate was 95%. The median SCAR scale score for incision scars was 2 points (range 1-3). Surgeons reported a favorable technical difficulty rating with a National Aeronautics and Space Administration Task Load Index (NASA-TLX) score of 30.7. RALP using the novel SR-SP robotic surgical platform is feasible, safe and effective in older children. The SR-SP surgical platform may serve as a promising alternative to the da Vinci SP surgical platform.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] A Single-Port Robotic Platform for Laparoscopic Surgery with a Large Central Channel for Additional Instrument
    Yung, K. L.
    Cheung, J. L. K.
    Chung, S. W.
    Singh, S.
    Yeung, C. K.
    ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (09) : 2211 - 2221
  • [32] A Single-Port Robotic Platform for Laparoscopic Surgery with a Large Central Channel for Additional Instrument
    K. L. Yung
    J. L. K. Cheung
    S. W. Chung
    S. Singh
    C. K. Yeung
    Annals of Biomedical Engineering, 2017, 45 : 2211 - 2221
  • [33] Early Experience With Pediatric Single-port Robotic Pyeloplasty Compared to Multiport Robotic Cohorts. Reply
    Bayne, Christopher E.
    Smith, Jordan M.
    JOURNAL OF UROLOGY, 2023, 210 (05):
  • [34] Single-port laparoscopic hysterectomy: preliminary results
    Tormena, Renata Assef
    Ribeiro, Sergio Conti
    Maciel, Gustavo Arantes
    Baracat, Edmund Chada
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2015, 61 (05): : 446 - 451
  • [35] Single-Port Robotic-Assisted Laparoscopic Sacrocolpopexy With Magnetic Retraction: A Video Demonstration
    Goueli, Ramy
    Rodriguez, Dayron
    Hess, Deborah
    Ganesan, Vishnuvardhan
    Carmel, Maude
    UROLOGY, 2020, 143 : 258 - 260
  • [36] Assistant port is unnecessary for robotic-assisted laparoscopic pyeloplasty in children: a comparative cohort study
    Danacioglu, Yavuz Onur
    Keser, Ferhat
    Polat, Salih
    Gunaydin, Bilal
    Comez, Yusuf Ilker
    Silay, Mesrur Selcuk
    PEDIATRIC SURGERY INTERNATIONAL, 2022, 38 (09) : 1327 - 1334
  • [37] Safety and feasibility of single-port laparoscopic appendectomy as a training procedure for surgical residents
    Paik, Kwang Yeol
    Yoon, Seung Hoon
    Kim, Sung Geun
    JOURNAL OF MINIMAL ACCESS SURGERY, 2020, 16 (01) : 13 - 17
  • [38] Assistant port is unnecessary for robotic-assisted laparoscopic pyeloplasty in children: a comparative cohort study
    Yavuz Onur Danacioglu
    Ferhat Keser
    Salih Polat
    Bilal Gunaydin
    Yusuf Ilker Comez
    Mesrur Selcuk Silay
    Pediatric Surgery International, 2022, 38 : 1327 - 1334
  • [39] Optimizing Prostate Cancer Surgery for Seniors: Single-Port Robotic-Assisted Platform
    Haberal, Hakan Bahadir
    Lambertini, Luca
    Avesani, Giulio
    Pettenuzzo, Greta
    Pacini, Matteo
    Valenzi, Fabio Maria
    Aljoulani, Muhannad
    Sauer, Ruben Calvo
    Torres-Anguiano, Juan Ramon
    Crivellaro, Simone
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2025,
  • [40] Feasibility and Surgical Outcomes of Hybrid Robotic Single-Site Hysterectomy Compared with Single-Port Access Total Laparoscopic Hysterectomy
    Noh, Joseph J.
    Jeon, Jung-Eun
    Jung, Ji-Hee
    Kim, Tae-Joong
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (07):