Construction of a high-sensitivity Cherenkov luminescence endoscopy system for the detection of gastrointestinal cancers

被引:0
|
作者
Yang, Ze [1 ,2 ,3 ]
Pang, Tian-Tian [4 ]
Wu, Zhuo-Jun [1 ,2 ]
Yan, Tian-Yu [5 ,6 ]
Yu, Jing-Min [1 ,2 ]
Wang, Xin-Yu [5 ,6 ]
Liu, Dan [1 ,2 ]
Lu, Xiao-Jian [7 ]
Kang, Xiao-Yu [1 ,2 ]
Li, Gui-Yu [8 ]
Bai, Cheng [3 ]
Xi, Xiao-Juan [1 ,2 ]
Tian, Zu-Hong [1 ,2 ]
Qi, Yu [1 ,2 ]
Zhang, Ming-Ru [8 ]
Kang, Fei [8 ]
Wang, Jing [8 ]
Chen, Xue-Li [5 ,6 ]
Wu, Kai-Chun [1 ,2 ]
机构
[1] Fourth Mil Med Univ, State Key Lab Holist Integrat Management Gastroint, Xian 710032, Peoples R China
[2] Fourth Mil Med Univ, Xijing Hosp Digest Dis, Natl Clin Res Ctr Digest Dis, Xian 710032, Peoples R China
[3] 967th Hosp PLA Joint Logist Support Force, Dept Gastroenterol, Dalian 116021, Liaoning, Peoples R China
[4] Northwestern Polytech Univ, Xian 710072, Peoples R China
[5] Xidian Univ, Engn Res Ctr Mol & Neuro Imaging, Minist Educ, Xian 710071, Peoples R China
[6] Xidian Univ, Sch Life Sci & Technol, Xian 710071, Peoples R China
[7] Nanjing Chunhui Sci & Technol Ind Co Ltd, Nanjing 210012, Peoples R China
[8] Fourth Mil Med Univ, Xijing Hosp, Dept Nucl Med, Xian 710032, Shaanxi, Peoples R China
来源
EJNMMI RESEARCH | 2025年 / 15卷 / 01期
基金
中国国家自然科学基金;
关键词
Cherenkov luminescence endoscopy; Cherenkov luminescence imaging; Gastrointestinal endoscopy; Molecular imaging; Diagnosis of gastrointestinal cancers; IMAGING-SYSTEM; CERENKOV; LIGHT; FEASIBILITY;
D O I
10.1186/s13550-025-01223-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background The diagnostic yield of conventional gastrointestinal (GI) endoscopy for early cancers is low because it is mainly based on morphological changes of tumors. Molecular functional changes in tumors precede morphological changes. Cherenkov luminescence endoscopy (CLE) system can perform molecular imaging of GI cancers, achieving early diagnosis of cancers. However, previous CLE systems had only been able to detect Cherenkov luminescence (CL) from about one mu Ci nuclide at a minimum (in vivo), but the nuclide probe absorbed by the tumor of a patient was often much less than one mu Ci at a routinely administered dose. This study aims to construct a clinically usable high-sensitivity CLE for molecular imaging of GI cancers. Results The minimum resolvable radioactivity of the CLE reached 0.020 mu Ci within 300 s (in vivo), with a sensitivity at the nanocurie for the first time. The detection sensitivity of the CLE increased by up to nearly twenty-two times over the previous system. In tumor-bearing nude mice, CLE could effectively identify all tumors with 100% concordance with both histopathology and PET/CT, and the CL signals of tumors were much stronger than those of the surrounding normal tissues (P < 0.05). The quality of CLE imaging at 60 s was comparable to that at 300 s (signal-to-background ratio, 2.70 +/- 0.48 versus 2.98 +/- 0.69, P = 0.56). Conclusions We constructed a high-sensitivity CLE that could detect radionuclides at the nanocurie radioactivity. The CLE could detect cancers accurately through rapid molecular imaging and had the potential for early diagnosis of GI cancers in clinical practice.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] HIGH-SENSITIVITY LUMINESCENCE SPECTROMETRY - PROGRESS IN ARCHAEOLOGICAL AND GEOLOGICAL DATING
    RIESER, U
    STOLZ, W
    KRBETSCHEK, MR
    NATURWISSENSCHAFTEN, 1994, 81 (12) : 558 - 560
  • [22] A HIGH-SENSITIVITY STRESSED PHOTOCONDUCTOR FOR OBSERVING LUMINESCENCE FROM GERMANIUM
    PEREZ, JM
    APPLIED PHYSICS LETTERS, 1985, 46 (05) : 492 - 493
  • [23] High-sensitivity detection of magnetically induced birefringence
    Muroo, K
    Namikawa, M
    Takubo, Y
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2000, 11 (01) : 32 - 37
  • [24] Silicon nanowires for high-sensitivity glucose detection
    Chen, Weiwei
    Yao, Hui
    Tzang, Chi Hung
    Zhu, Junjie
    Yang, Mengsu
    Lee, Shuit-Tong
    APPLIED PHYSICS LETTERS, 2006, 88 (21)
  • [25] High-Sensitivity Hyper-spectral Video Endoscopy System for Intra-Surgical Tissue Classification
    Arnold, Thomas
    De Biasio, Martin
    Leitner, Raimund
    2010 IEEE SENSORS, 2010, : 2612 - 2615
  • [26] HIGH-SENSITIVITY MAGNETIC RESONANCE BY BOLOMETER DETECTION
    SCHMIDT, J
    SOLOMON, I
    JOURNAL OF APPLIED PHYSICS, 1966, 37 (10) : 3719 - &
  • [27] HIGH-SENSITIVITY MATERIALS FOR GAS-DETECTION
    LALAUZE, R
    PIJOLAT, C
    VINCENT, S
    BRUNO, L
    SENSORS AND ACTUATORS B-CHEMICAL, 1992, 8 (03) : 237 - 243
  • [28] Silicon Nanowires for High-Sensitivity CRP Detection
    Lee, Min-Ho
    Jung, Suk Won
    Seong, Wookyeong
    Lee, Sangdae
    Kim, Gyeongshik
    2010 IEEE SENSORS, 2010, : 415 - 418
  • [29] High-sensitivity BK virus detection system using viewRNA in situ hybridization
    Hu, Chunlan
    Zhang, Xiaonan
    Zhu, Tongyu
    Hou, Yumin
    Shi, Yejing
    Sun, Jiajia
    Wu, Nannan
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2025, 112 (02)
  • [30] High-sensitivity Mercury Ion Detection System Using Unmodified Gold Nanorods
    Duan Qian-Qian
    Zhou Jia-Ling
    Li Peng-Wei
    Sun Li
    Zhuo Kai
    Zhang Yi-Xia
    Zhang Wen-Dong
    Sang Sheng-Bo
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 46 (09) : E1874 - E1879