Experimental Study on Prestress Loss and Pull-out Behavior of Rock Bolts

被引:0
|
作者
Chen, Bailing [1 ]
Gao, Haiyang [2 ]
Wang, Lianguang [3 ]
Zhang, Yaosheng [4 ]
机构
[1] Northeastern Univ, Sch Resources & Civil Engn, Shenyang 110819, Peoples R China
[2] Shenyang Univ Technol, Sch Architecture & Civil Engn, Shenyang 110870, Peoples R China
[3] Jilin Univ Architecture & Technol, Changchun 130114, Peoples R China
[4] Guangxi Commun Design Grp Co Ltd, Nanning 530000, Peoples R China
基金
中国国家自然科学基金;
关键词
Prestressed grouted rock bolt; Prestress loss; Pull-out behavior; Weathered rock formation; In-situ test; ANCHORAGE; MODEL;
D O I
10.1007/s13296-024-00914-8
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
For mountain wind power towers, the foundation adopts rock anchor foundation, which can fully utilize the bearing capacity of the bedrock and achieve the goal of shortening the construction period and saving investment. However, there is still few studies on the mechanical properties of prestressed wedge-grouted rock bolts (PWRBs). The research on rock bolts under prestressed conditions is also limited to scale experiments and steel casing experiments, lacking accurate and reliable on-site full-scale prestressed rock bolt pull-out test results and analysis. Therefore, field pull-out tests in weathered rock formations for prestressed grouted rock bolts (PGRBs) and PWRBs with lengths of 8.0 m, 10.5 m, and 13.0 m, respectively, were conducted to investigate the pull-out behavior and prestress loss of these two types of rock bolts. The test results show that the prestress loss ratio of two types of rock bolts is generally around 15%, and the maximum prestress loss ratio can reach 25%. Besides, the failure mode of two types of rock bolts was that the the steel bars fractured in the free section and were not pulled out. The pull-out bearing capacity of PWRBs is higher than that of PGRBs. Using the prestressed rock bolts with 8.0 m bolt length (6.0 m anchored length) to construct wind turbine tower foundation in strongly weathered rocks can meet the design requirements.
引用
收藏
页码:233 / 244
页数:12
相关论文
共 50 条
  • [31] Expansion and Pull-Out Simulation Test of Self-expanding Bond Bolts in Adjacent Rock Bodies with Varied Stiffnesses
    Yunzhou Li
    Jie Liu
    Hongya Li
    Rongqi Sun
    Rui Song
    Zhao Li
    KSCE Journal of Civil Engineering, 2022, 26 : 1592 - 1605
  • [32] Expansion and Pull-Out Simulation Test of Self-expanding Bond Bolts in Adjacent Rock Bodies with Varied Stiffnesses
    Li, Yunzhou
    Liu, Jie
    Li, Hongya
    Sun, Rongqi
    Song, Rui
    Li, Zhao
    KSCE JOURNAL OF CIVIL ENGINEERING, 2022, 26 (04) : 1592 - 1605
  • [33] CONCRETE STRENGTH DETERMINATION BY PULL-OUT TESTS ON WEDGE-ANCHOR BOLTS
    BUNGEY, JH
    CHABOWSKI, AJ
    BRYDENSMITH, DW
    BRAESTRUP, MW
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 2-RESEARCH AND THEORY, 1982, 73 (MAR): : 249 - 252
  • [34] Investigation of the Bearing Characteristics of Bolts on a Coal-Rock Combined Anchor Body under Different Pull-Out Rates
    Zhang, Pandong
    Gao, Lin
    Zhan, Xinyu
    Liu, Pengze
    Kang, Xiangtao
    Ma, Zhenqian
    Wang, Yongyin
    Liu, Ping
    Han, Sen
    ENERGIES, 2022, 15 (09)
  • [35] Experimental evaluation of the pull-out behavior of suction caissons in saturated sand soil
    Kayadelen, Cafer
    Altay, Gokhan
    Ozturk, Mitat
    Onal, Yakup
    OCEAN ENGINEERING, 2023, 286
  • [36] CONCRETE STRENGTH DETERMINATION BY PULL-OUT TESTS ON WEDGE-ANCHOR BOLTS
    BUNGEY, JH
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 2-RESEARCH AND THEORY, 1981, 71 (JUN): : 379 - 394
  • [37] Temperature related pull-out performance of chemical anchor bolts in fibre concrete
    Richardson, A. E.
    Dawson, S.
    Campbell, L.
    Moore, G.
    Mc Kenzie, C.
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 196 : 478 - 484
  • [38] Pull-out behaviour of blind bolts from concrete-filled tubes
    Oktavianus, Yusak
    Yao, Huang
    Goldsworthy, Helen M.
    Gad, Emad F.
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2015, 168 (10) : 747 - 759
  • [39] Experimental study on yarn friction slip in the yarn pull-out test
    Li, Weikang
    Lei, Zhenkun
    Qin, Fuyong
    Ba, Ruixiang
    Fang, Qingchao
    CIVIL, ARCHITECTURE AND ENVIRONMENTAL ENGINEERING, VOLS 1 AND 2, 2017, : 847 - 850
  • [40] Experimental Study on Bolt Pull-Out Property Coupled by Plate and Shotcrete
    Liu, Xiliang
    Guo, Jiaqi
    Wan, Long
    Wang, Jianhua
    OPERATIONAL AND ENVIRONMENTAL MINE HEALTH AND SAFETY PRACTICE AND INNOVATION, 2016, : 459 - 464