High-Sensitivity Magnetic Field Sensor Based on an Optoelectronic Oscillator with a Mach-Zehnder Interferometer

被引:0
|
作者
Zhu, Mingjian [1 ]
Gao, Pufeng [1 ]
Cai, Shiyi [1 ]
Zhang, Naihan [2 ,3 ]
Wu, Beilei [1 ]
Liu, Yan [1 ]
Yin, Bin [4 ]
Wang, Muguang [1 ]
机构
[1] Beijing Jiaotong Univ, Inst Lightwave Technol, Minist Educ, Key Lab All Opt Network & Adv Telecommun Network, Beijing 100044, Peoples R China
[2] China United Network Commun Grp Corp Ltd, Beijing 100033, Peoples R China
[3] Beijing Univ Posts & Telecommun, Sch Informat & Commun Engn, Beijing 100876, Peoples R China
[4] Ocean Univ China, Coll Informat Sci & Engn, Qingdao 266100, Peoples R China
基金
中国国家自然科学基金;
关键词
microwave photonics; optical fiber sensing; optoelectronic oscillator; Mach-Zehnder interferometer; magnetic field measurement; FABRY-PEROT;
D O I
10.3390/s25051621
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-sensitivity magnetic field sensor based on an optoelectronic oscillator (OEO) with a Mach-Zehnder interferometer (MZI) is proposed and experimentally demonstrated. The magnetic field sensor consists of a fiber Mach-Zehnder interferometer, with the lower arm of the interferometer wound around a magnetostrictive transducer. Due to the magnetostrictive effect, an optical phase shift induced by magnetic field variation is generated between two orthogonal light waves transmitted in the upper and lower arms of the MZI. The polarization-dependent property of a Mach-Zehnder modulator (MZM) is utilized to transform the magnetostrictive phase shift into the phase difference between the sidebands and optical carrier, which is mapped to the oscillating frequency upon the completion of an OEO loop. High-sensitivity magnetic field sensing is achieved by observing the frequency shift of the radio frequency (RF) signal. Temperature-induced cross-sensitivity is mitigated through precise length matching of the MZI arms. In the experiment, the high magnetic field sensitivity of 6.824 MHz/mT with a range of 25 mT to 25.3 mT is achieved and the sensing accuracy measured by an electrical spectrum analyzer (ESA) at "maxhold" mode is 0.002 mT. The proposed sensing structure has excellent magnetic field detection performance and provides a solution for temperature-insensitive magnetic field detection, which would have broad application prospects.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] A Simple High-Sensitivity Sensor Based on Multimode Mach-Zehnder Interference for Refractive Index Measurement
    Wu, Yupeng
    Wang, Qianjin
    Li, Yuxin
    Li, Miao
    Pan, Meiting
    Zhou, Xue
    Yan, Xin
    Zhao, Yong
    Cheng, Tonglei
    IEEE SENSORS JOURNAL, 2024, 24 (19) : 30161 - 30167
  • [42] High resolution and large measurement range voltage sensing based on an optoelectronic oscillator utilizing an unbalanced Mach-Zehnder interferometer
    Wu, Beilei
    Chen, Hong
    Wang, Muguang
    Yin, Bin
    Ma, Jiuyang
    Zhao, Xiaotong
    Xiao, Shiying
    Cai, Shiyi
    Yan, Fengping
    OPTICS EXPRESS, 2024, 32 (05) : 8030 - 8041
  • [43] All Fiber Mach-Zehnder Interferometer Based on Intracavity Micro-Waveguide for a Magnetic Field Sensor
    Chen, Maoqing
    Liu, Qifeng
    Zhao, Yong
    APPLIED SCIENCES-BASEL, 2021, 11 (23):
  • [44] High-sensitivity temperature sensor based on an optoelectronic oscillator
    Zhu, Yanhong
    Jin, Xiaofeng
    Chi, Hao
    Zheng, Shilie
    Zhang, Xianmin
    APPLIED OPTICS, 2014, 53 (22) : 5084 - 5087
  • [45] A dual tapered Mach-Zehnder Interferometer for Magnetic Field Sensing
    Hernandez-Robles, E. A.
    Estudillo-Ayala, J. M.
    Sierra-Hernandez, J. M.
    Jauregui-Vazquez, D. F.
    Hernandez-Garcia, J. C.
    Rojas-Laguna, R.
    Martinez-Angulo, J. R.
    PHOTONIC FIBER AND CRYSTAL DEVICES: ADVANCES IN MATERIALS AND INNOVATIONS IN DEVICE APPLICATIONS XI, 2017, 10382
  • [46] Robust Strain Sensor with High Sensitivity Based on Polymer-Encapsulated Microfiber Mach-Zehnder Interferometer
    Xiao, Bin
    Zhuang, Funa
    Wang, Jing
    Yao, Zhongyu
    Wang, Shanshan
    POLYMERS, 2024, 16 (19)
  • [47] All-Fiber high-sensitivity temperature sensor based on Mach-Zehnder interferometer with a little lateral-offset splicing for seawater
    Liu, Ruijie
    Lv, Riqing
    Lin, Ziting
    Zhao, Jincheng
    Zheng, Hongkun
    Cai, Lu
    Zhao, Yong
    MEASUREMENT, 2025, 247
  • [48] Phase Sensitivity and Entanglement of Mach-Zehnder Interferometer
    Xiu-Xia Hu
    International Journal of Theoretical Physics, 2016, 55 : 2794 - 2799
  • [49] Temperature sensitivity of waveguide Mach-Zehnder interferometer
    Dullo, Firehun Tsige
    Sokolov, Viktor
    Chauvet, Cyprien
    Lindecrantz, Susan
    Solbo, Stian Andre
    Helleso, Olav Gaute
    INTEGRATED OPTICS: DEVICES, MATERIALS, AND TECHNOLOGIES XVIII, 2014, 8988
  • [50] Ultracompact and high sensitive refractive index sensor based on Mach-Zehnder interferometer
    Yu, Huaqing
    Xiong, Liangbin
    Chen, Zhihong
    Li, Qianguang
    Yi, Xunong
    Ding, Yu
    Wang, Feng
    Lv, Hao
    Ding, Yaoming
    OPTICS AND LASERS IN ENGINEERING, 2014, 56 : 50 - 53