Segmentation methods and dosimetric evaluation of 3D-printed immobilization devices in head and neck radiotherapy

被引:0
|
作者
Yin, Yunpeng [1 ,2 ]
Zhang, Weisha [2 ]
Zou, Lian [2 ]
Liu, Xiangxiang [2 ]
Yu, Luxin [2 ]
Wang, Ming [1 ]
机构
[1] Chengdu Univ Technol, Coll Nucl Technol & Automat Engn, Chengdu 610059, Peoples R China
[2] Univ Elect Sci & Technol China, Sichuan Prov Peoples Hosp, Canc Ctr, Chengdu 610072, Peoples R China
关键词
Radiation therapy; 3D printing; Image segmentation; MODULATED RADIATION-THERAPY; IMRT; CANCER; IMPACT; ARC;
D O I
10.1186/s12885-025-13669-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background Treatment planning systems (TPS) often exclude immobilization devices from optimization and calculation, potentially leading to inaccurate dose estimates. This study employed deep learning methods to automatically segment 3D-printed head and neck immobilization devices and evaluate their dosimetric impact in head and neck VMAT. Methods Computed tomography (CT) positioning images from 49 patients were used to train the Mask2Former model to segment 3D-printed headrests and MFIFs. Based on the results, four body structure sets were generated for each patient to evaluate the impact on dose distribution in volumetric modulated arc therapy (VMAT) plans: S (without immobilization devices), S_(MF) (with MFIFs), S_3D (with 3D-printed headrests), and S_(3D+MF) (with both). VMAT plans (P, P_(MF), P_(3D), and P_(3D+MF)) were created for each structure set. Dose-volume histogram (DVH) data and dose distribution of the four plans were compared to assess the impact of the 3D-printed headrests and MFIFs on target and normal tissue doses. Gafchromic EBT3 film measurements were used for patient-specific verification to validate dose calculation accuracy. Results The Mask2Former model achieved a mean average precision (mAP) of 0.898 and 0.895, with a Dice index of 0.956 and 0.939 for the 3D-printed headrest on the validation and test sets, respectively. For the MFIF, the Dice index was 0.980 and 0.981 on the validation and test sets, respectively. Compared to P, P_MF reduced the V-100% for PGTVnx, PGTVnd, PGTVrpn, PTV1, and PTV2 by 5.99%, 6.51%, 5.93%, 2.24%, and 1.86%, respectively(P <= 0.004). P_3D reduced the same targets by 1.78%, 2.56%, 1.75%, 1.16%, and 1.48%(P < 0.001), with a 31.3% increase in skin dose (P < 0.001). P_(3D+MF) reduced the V-100% by 9.15%, 10.18%, 9.16%, 3.36%, and 3.28% (P < 0.001), respectively, while increasing the skin dose by 31.6% (P < 0.001). EBT3 film measurements showed that the P_(3D+MF) dose distribution was more aligned with actual measurements, achieving a mean gamma pass rate of 92.14% under the 3%/3 mm criteria. Conclusions This study highlights the potential of Mask2Former in 3D-printed headrest and MFIF segmentation automation, providing a novel approach to enhance personalized radiation therapy plan accuracy. The attenuation effects of 3D-printed headrests and MFIFs reduce V-100% and D-mean for PTVs in head and neck cancer patients, while the buildup effects of 3D-printed headrests increases the skin dose (31.3%). Challenges such as segmentation inaccuracies for small targets and artifacts from metal fasteners in MFIFs highlight the need for model optimization and validation on larger, more diverse datasets.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Individualized 3D-Printed Tissue Retraction Devices for Head and Neck Radiotherapy
    Herpel, Christopher
    Schwindling, Franz Sebastian
    Held, Thomas
    Christ, Leo
    Lang, Kristin
    Schwindling, Martha
    Moratin, Julius
    Zaoui, Karim
    Moutsis, Tracy
    Plinkert, Peter
    Herfarth, Klaus
    Freudlsperger, Christian
    Rammelsberg, Peter
    Debus, Jurgen
    Adeberg, Sebastian
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [2] Design of 3D-printed universal oral stent for tongue immobilization in head and neck radiotherapy
    Mundee, Thunpisit
    Jongwannasiri, Chavin
    Fuangrod, Todsaporn
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (01)
  • [3] Dosimetric evaluation of a patient-specific 3D-printed oral positioning stent for head-and-neck radiotherapy
    Cleland, Susannah
    Chan, Philip
    Chua, Benjamin
    Crowe, Scott B.
    Dawes, Jodi
    Kenny, Lizbeth
    Lin, Charles
    Obereigner, Elise
    Peet, Samuel C.
    Trapp, Jamie V.
    Poroa, Tania
    Kairn, Tanya
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (03) : 887 - 899
  • [4] Dosimetric evaluation of a patient-specific 3D-printed oral positioning stent for head-and-neck radiotherapy
    Susannah Cleland
    Philip Chan
    Benjamin Chua
    Scott B. Crowe
    Jodi Dawes
    Lizbeth Kenny
    Charles Lin
    Elise Obereigner
    Samuel C. Peet
    Jamie V. Trapp
    Tania Poroa
    Tanya Kairn
    Physical and Engineering Sciences in Medicine, 2021, 44 : 887 - 899
  • [5] Radiotherapy Immobilization Mask Molding Through the Use of 3D-Printed Head Models
    Pham, Quoc-Viet Vincent
    Lavallee, Annie-Pier
    Foias, Alexandru
    Roberge, David
    Mitrou, Ellis
    Wong, Philip
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2018, 17 : 1 - 8
  • [6] A framework for clinical commissioning of 3D-printed patient support or immobilization devices in photon radiotherapy
    Meyer, Tyler
    Quirk, Sarah
    D'Souza, Malgorzata
    Spencer, David
    Roumeliotis, Michael
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05): : 499 - 505
  • [7] 3D printed immobilization for head and neck cancer radiotherapy: A pilot study on patients
    Michiels, S.
    Poels, K.
    Nuyts, S.
    Depuydt, T.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S886 - S887
  • [8] Design and extensive validation of a 3D-printed patient-specific head & neck immobilization device
    Dewit, Bertrand
    Dotremont, Kevin
    Konings, Dennis
    Vanstraelen, Bianca
    Peeters, Ronald
    Slagmolen, Pieter
    Depuydt, Tom
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4080 - S4082
  • [9] Oral Sequelae after Head and Neck Radiotherapy: RCT Comparing 3D-Printed Tissue Retraction Devices with Conventional Dental Splints
    Herpel, Christopher
    Held, Thomas
    Labis, Christos
    Christ, Leo
    Lang, Kristin
    Regnery, Sebastian
    Eichkorn, Tanja
    Lentz-Hommertgen, Adriane
    Jaekel, Cornelia
    Moratin, Julius
    Semmelmayer, Karl
    Moutsis, Tracy Thecla
    Plath, Karim
    Ristow, Oliver
    Freudlsperger, Christian
    Adeberg, Sebastian
    Debus, Juergen
    Rammelsberg, Peter
    Schwindling, Franz Sebastian
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (08)
  • [10] Development of a customisable 3D-printed intra-oral stent for head-and-neck radiotherapy
    Cleland, Susannah
    Crowe, Scott B.
    Chan, Philip
    Chua, Benjamin
    Dawes, Jodi
    Kenny, Lizbeth
    Lin, Charles Y.
    McDowall, William R.
    Obereigner, Elise
    Poroa, Tania
    Stewart, Kate
    Kairn, Tanya
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2022, 23 : 1 - 7