Seismic Response of Foundation Settlement for Liquid Storage Structure in Collapsible Loess Areas

被引:0
|
作者
Huang, Wenji [1 ]
Cao, Xianhui [2 ]
Xie, Hongyi [2 ]
Sun, Haodong [2 ]
Cheng, Xuansheng [2 ]
机构
[1] Water Resources & Hydropower Engn Co Ltd, Gansu Dayu Water Saving Grp, Lanzhou 730050, Peoples R China
[2] Lanzhou Univ Technol, Western Engn Res Ctr Disaster Mitigat Civil Engn, Minist Educ, Lanzhou 730050, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 19期
关键词
loess region; foundation failure; liquid storage structure; seismic action; dynamic response; TANK;
D O I
10.3390/app14198993
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
To investigate the impact of foundation settlement in loess areas on the dynamic response of liquid storage structure (LSS) under seismic motion, a finite element analysis model of the liquid-solid coupling of LSS was established using ADINA V9.6 software. By analyzing the dynamic response patterns of LSS under seismic motion with foundation failure, this study examines the effects of foundation failure and the direction of seismic wave incidence on the equivalent stress, maximum shear stress, wall displacement, and liquid sloshing wave height of the structure. The results indicate that among the three foundation failure scenarios, foundation failure at the center of the tank bottom has the least impact on the structural dynamic response. In contrast, foundation failure affecting one-fourth of the tank base has the greatest impact. Furthermore, compared to seismic motion along the X-axis, the dynamic response of the structure is more significantly affected when seismic motion co-occurs along the X-Z-axis.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Seismic response and fragility analysis of a water storage structure
    Bhargava, K
    Ghosh, AK
    Ramanujam, S
    NUCLEAR ENGINEERING AND DESIGN, 2005, 235 (14) : 1481 - 1501
  • [32] The Effect of Topographic Irregularities on Seismic Response of the Concrete Rectangular Liquid Storage Tanks Incorporating Soil–Structure–Liquid Interaction
    M. H. Asgari
    M. I. Khodakarami
    R. Vahdani
    Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2020, 44 : 1179 - 1197
  • [33] Seismic response of base isolated liquid storage ground tanks
    Seleemah, Ayman A.
    El-Sharkawy, Mohamed
    AIN SHAMS ENGINEERING JOURNAL, 2011, 2 (01) : 33 - 42
  • [34] Seismic response analysis of adjacent liquid-storage tanks
    Mykoniou, Konstantinos
    Butenweg, Christoph
    Holtschoppen, Britta
    Klinkel, Sven
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2016, 45 (11): : 1779 - 1796
  • [35] SEISMIC RESPONSE ANALYSIS OF CYLINDRICAL LIQUID STORAGE TANKS.
    SHINKE, T.
    ZUI, H.
    1981, V 31 (N 1): : 62 - 67
  • [36] Seismic response of base-isolated liquid storage tanks
    Shrimali, MK
    Jangid, RS
    JOURNAL OF VIBRATION AND CONTROL, 2003, 9 (10) : 1201 - 1218
  • [37] Seismic response of liquid storage tanks isolated by sliding bearings
    Shrimali, MK
    Jangid, RS
    ENGINEERING STRUCTURES, 2002, 24 (07) : 909 - 921
  • [38] Experimental Investigations of the Seismic Response of a Large Underground Structure at a Soft Loess Site
    Chen, Xuan
    Xiong, Zhongming
    Ren, Chenhao
    Liu, Yue
    BUILDINGS, 2023, 13 (07)
  • [39] Seismic response of foundation-mat structure subjected to local uplift
    El Abbas, Nadia
    Khamlichi, Abdellatif
    Bezzazi, Mohammed
    COUPLED SYSTEMS MECHANICS, 2016, 5 (04): : 285 - 304
  • [40] Sensitivity analysis of mass ratio effect on settlement and seismic response of shallow foundation using numerical simulation
    Ko, Kil-Wan
    Ha, Jeong-Gon
    Lee, Jinsun
    Cho, Gye-Chun
    GEOMECHANICS AND ENGINEERING, 2023, 34 (06) : 649 - 664