Shear Fragility Analysis of Non-Classically Damped Three-Dimensional Structures Under Seismic Excitation

被引:0
|
作者
Wang, Jinghui [1 ,2 ]
Tan, Ping [1 ,2 ,3 ]
Huang, Tiancan [3 ]
He, Xuefeng [3 ]
Zhou, Fulin [2 ,3 ]
机构
[1] Guangzhou Univ, Sch Civil Engn & Transportat, Guangzhou 510006, Peoples R China
[2] Minist Educ, Key Lab Earthquake Resistance Earthquake Mitigat &, Guangzhou 510006, Peoples R China
[3] Guangzhou Univ, Earthquake Engn Res & Test Ctr, Guangzhou 510006, Peoples R China
基金
中国国家自然科学基金;
关键词
fragility analysis; non-classically damping; VUEL; CM-RSM; FD-RSM; DESIGN; FRAME;
D O I
10.3390/buildings14123967
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study proposes a seismic performance evaluation method for structures using the base shear index to calculate the collapse probability. After non-proportional damping was applied to the three-dimensional bar system model, the structural dynamic response was computed through large-scale finite element analysis. A three-dimensional matrix element for calculating viscous dampers was established in this study. The viscous unified elastoplastic (VUEL) damper element program was compiled using the Fortran language into the ABAQUS 6.14 software. An incremental dynamic analysis (IDA) routine was developed using Python 3.0 within the environment of ABAQUS. The uncontrolled structure was designed using the forced decoupling response spectrum method (FD-RSM), while the damped structure was designed using the complex modal response spectrum method (CM-RSM). Seismic fragility analysis was conducted on both uncontrolled and damped structures using the recommended far-field and near-field earthquake records from ATC-63 FEMAP-695. The shear-based fragility index and collapse probability were investigated to comprehensively assess the seismic performance of the uncontrolled and damped structures. The analysis results indicated that the ratios of the limit performance states for moderate damage (IO), severe damage (LS), and complete damage (CP) in the structure were 1:1.6:2.6. Compared with the various limit performance states of the uncontrolled structures, the increments in the moderate, severe, and complete damage limit performance states of the damped structures were 12.79%, 14.86%, and 16.97%, respectively.
引用
收藏
页数:27
相关论文
共 50 条
  • [11] Complex modes superposition in non-classically damped structures
    Cortes, F.
    Elejabarrieta, M. J.
    Structural Dynamics - EURODYN 2005, Vols 1-3, 2005, : 2171 - 2176
  • [12] ERRORS IN RESPONSE CALCULATIONS FOR NON-CLASSICALLY DAMPED STRUCTURES
    WARBURTON, GB
    SONI, SR
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1977, 5 (04): : 365 - 376
  • [13] CQC and SRSS methods for non-classically damped structures - Response
    Igusa, T
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1996, 25 (04): : 415 - 415
  • [14] Statistics of ordered peaks in the response of non-classically damped structures
    Gupta, ID
    Trifunac, MD
    PROBABILISTIC ENGINEERING MECHANICS, 1999, 14 (04) : 329 - 337
  • [15] CQC and SRSS methods for non-classically damped structures - Discussion
    Villaverde, R
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1996, 25 (04): : 413 - 414
  • [16] Perturbation spectrum method for seismic analysis of non-classically damped systems附视频
    Wei GUOHongnan LIZhen GUO State Key Laboratory of Coastal and Offshore EngineeringFaculty of Infrastructure EngineeringDalian University of TechnologyDalian China Department of Civil EngineeringZhejiang UniversityHangzhou China
    Journal of Zhejiang University-Science A(Applied Physics & Engineering), 2010, (05) : 325 - 334
  • [17] Vibration analysis of non-classically damped linear systems
    Liu, ZS
    Song, DT
    Huang, C
    Wang, DJ
    Chen, SH
    JOURNAL OF VIBRATION AND ACOUSTICS-TRANSACTIONS OF THE ASME, 2004, 126 (03): : 456 - 458
  • [18] Blind modal identification of non-classically damped structures under non-stationary excitations
    Ghahari, S. F.
    Abazarsa, F.
    Taciroglu, E.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2017, 24 (06):
  • [19] Modal identification of non-classically damped structures using generalized sparse component analysis
    Yao, Xiao-Jun
    Yi, Ting-Hua
    Qu, Chun-Xu
    Li, Hong-Nan
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2024, 33 (08):
  • [20] Time-domain analysis for dynamic responses of non-classically damped composite structures
    Sun, Panxu
    Yang, Hong
    Kang, Le
    COMPOSITE STRUCTURES, 2020, 251