Kolmogorov-Arnold Network in the Fault Diagnosis of Oil-Immersed Power Transformers

被引:0
|
作者
Cabral, Thales W. [1 ]
Gomes, Felippe V. [2 ]
de Lima, Eduardo R. [3 ]
Filho, Jose C. S. S. [1 ]
Meloni, Luis G. P. [1 ]
机构
[1] Univ Estadual Campinas, Sch Elect & Comp Engn, Dept Commun, BR-13083852 Campinas, Brazil
[2] Transmissora Alianca Energia Elect SA TAESA, Praca Quinze de Novembro,Ctr, BR-20010010 Rio De Janeiro, Brazil
[3] Inst Pesquisa Eldorado, Dept Hardware Design, BR-13083898 Campinas, Brazil
关键词
Kolmogorov-Arnold Network; power transformers; DGA sensoring; fault diagnosis; artificial intelligence; DISSOLVED-GAS ANALYSIS; FUZZY-LOGIC;
D O I
10.3390/s24237585
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Instabilities in energy supply caused by equipment failures, particularly in power transformers, can significantly impact efficiency and lead to shutdowns, which can affect the population. To address this, researchers have developed fault diagnosis strategies for oil-immersed power transformers using dissolved gas analysis (DGA) to enhance reliability and environmental responsibility. However, the fault diagnosis of oil-immersed power transformers has not been exhaustively investigated. There are gaps related to real scenarios with imbalanced datasets, such as the reliability and robustness of fault diagnosis modules. Strategies with more robust models increase the overall performance of the entire system. To address this issue, we propose a novel approach based on Kolmogorov-Arnold Network (KAN) for the fault diagnosis of power transformers. Our work is the first to employ a dedicated KAN in an imbalanced data real-world scenario, named KANDiag, while also applying the synthetic minority based on probabilistic distribution (SyMProD) technique for balancing the data in the fault diagnosis. Our findings reveal that this pioneering employment of KANDiag achieved the minimal value of Hamming loss-0.0323-which minimized the classification error, guaranteeing enhanced reliability for the whole system. This ground-breaking implementation of KANDiag achieved the highest value of weighted average F1-Score-96.8455%-ensuring the solidity of the approach in the real imbalanced data scenario. In addition, KANDiag gave the highest value for accuracy-96.7728%-demonstrating the robustness of the entire system. Some key outcomes revealed gains of 68.61 percentage points for KANDiag in the fault diagnosis. These advancements emphasize the efficiency and robustness of the proposed system.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Novel Probabilistic Neural Network Models Combined with Dissolved Gas Analysis for Fault Diagnosis of Oil-Immersed Power Transformers (vol 6, pg 18083, 2021)
    Zhou, Yichen
    Tao, Lingyu
    Yang, Xiaohui
    Yang, Li
    ACS OMEGA, 2022, 7 (20): : 17501 - 17501
  • [32] A New Method for Oil-Immersed Transformers Fault Diagnosis Based on Evidential Reasoning Rule With Optimized Probabilistic Distributed
    Jina, E.
    Zhang, Yunyi
    He, Wei
    Zhang, Wei
    Cao, You
    Lv, Gang
    IEEE ACCESS, 2024, 12 : 34289 - 34305
  • [33] Fault diagnosis of oil-immersed transformers based on the improved sparrow search algorithm optimised support vector machine
    Ding, Can
    Ding, Qingchang
    Wang, Zhenyi
    Zhou, Yiyuan
    IET ELECTRIC POWER APPLICATIONS, 2022, 16 (09) : 985 - 995
  • [34] Health status perception of oil-immersed power transformers considering wind power uncertainty
    Yi, Lingzhi
    Su, Xingren
    Wang, Yahui
    Xu, Xunjian
    Liu, Jiangyong
    She, Haixiang
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 234
  • [35] Application of Oil-immersed Transformer Fault Diagnosis Based on Modified Neural Network Combined with PSO
    Huang, Xiongjian
    Han, Haojiang
    Chai, Jun
    Zhu, Qing
    Cai, Hao
    Zhao, Tao
    2021 IEEE THE 4TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY APPLICATIONS (ICPEA 2021), 2021, : 13 - 17
  • [36] Electrical insulation diagnostic method and maintenance criteria for oil-immersed power transformers
    Okubo, H.
    Kobayashi, S.
    Aoshima, Y.
    Takagi, H.
    Mori, E.
    Ikeda, M.
    Kishi, A.
    IEEE International Conference on Conduction and Breakdown in Dielectric Liquids, ICDL, 1999, : 372 - 377
  • [37] On Thermal Performance Analysis of Oil-Immersed Power Transformers: Winding Cooling Curve
    Gamil, A.
    Schluecker, E.
    2022 7TH INTERNATIONAL ADVANCED RESEARCH WORKSHOP ON TRANSFORMERS (ARWTR 2022), 2022, : 1 - 6
  • [38] Analyzing and Comparing Thermal Models of Indoor and Outdoor Oil-Immersed Power Transformers
    Mamizadeh, A.
    Iskender, I.
    2009 IEEE BUCHAREST POWERTECH, VOLS 1-5, 2009, : 3042 - 3049
  • [39] A fast computational method for internal temperature field in Oil-Immersed power transformers
    Liu, Gang
    Hu, Wanjun
    Hao, Shiyuan
    Gao, Chenglong
    Liu, Yunpeng
    Wu, Weige
    Li, Lin
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [40] The DGA Interpretation Method Using Relative Content of Characteristic Gases and Gas-ratio Combinations for Fault Diagnosis of Oil-immersed Power Transformers
    Zhao, An-xin
    Tang, Xiao-jun
    Zhang, Zhong-hua
    Liu, Jun-hua
    PROCEEDINGS OF 2014 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2014), 2014, : 124 - 127