An Efficient Method for Estimating Inertia of a PV-Integrated Power Grid for Enhanced Security

被引:0
|
作者
Ghosh S. [1 ]
Isbeih Y.J. [1 ]
Moursi M.S.E. [1 ]
El-Saadany E.F. [1 ]
机构
[1] Department of Electrical Engineering, Advanced Power and Energy Center (APEC), Khalifa University, Abu Dhabi
关键词
Accuracy; Estimation; Frequency estimation; Generators; Inertia constant estimation; kalman filter; phasor measurement unit (PMU); Phasor measurement units; Real-time systems; recursive least square (RLS) identification; Security;
D O I
10.1109/TSG.2024.3425909
中图分类号
学科分类号
摘要
The decommissioning of traditional thermal power plants with high levels of renewable energy resources (RES) always causes a reduction in system inertia. A hybrid power grid must maintain stable frequency during severe disturbances. Therefore, this study provides a generalized approach for estimating the online grid inertia under normal and disturbed operating conditions. Large-scale deployment of photovoltaic (PV) power generation is considered to replicate the rapid growth of RES and its impact on actual power grids. The individual inertia of existing conventional synchronous generators in the hybrid system is quickly estimated using the online recursive least square (RLS) method. A Kalman filter is used to reject any noise contained in the measured signals. The noise-free rate of change of frequency (RoCoF) and electrical power are further used to refine the estimation of inertia, damping coefficient, and mechanical power to enhance the overall accuracy of the proposed tracking scheme. Next, the virtual inertia of the existing PV system is derived mathematically from the identified model parameters, which are further verified using simulation results, thereby demonstrating the robustness of the proposed approach. Finally, the spectral cluster-based method is used to determine the sets of coherent machines and provide online tracking for each coherent group’s inertia, as well as the total grid inertia in response to different disturbances and intermittency of RES power generation. The proposed inertia estimation method is proven to be very fast, allowing preventative action to be taken before any instability occurs.The effectiveness of the proposed method is tested and verified using IEEE 39-bus, 68-bus, an islanded AC microgrid, as well as a modified IEEE 39-bus based MTDC test system. Authors
引用
收藏
页码:1 / 1
相关论文
共 50 条
  • [31] Power coupling and grid-connected support control of the PV/ESS power generation system with virtual inertia
    Peng, Yan
    Ma, Junchao
    Wang, Chenxu
    Zhang, Xiangyu
    Lan, Yixi
    ENERGY REPORTS, 2023, 9 : 946 - 953
  • [32] An integrated security framework for GOSS power grid analytics platform
    Gibson, Tara
    Ciraci, Selim
    Sharma, Poorva
    Allwardt, Craig
    Rice, Mark
    Akyol, Bora
    Proceedings of the International Conference on Dependable Systems and Networks, 2014, : 786 - 791
  • [33] Integrated Wide Area Protection and Control for Power Grid Security
    Wang, Qingping
    Bo, Zhiqian
    Zhao, Yingke
    Ma, Xiaowei
    Zhang, Ming
    Zheng, Hao
    Wang, Lin
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2019, 5 (02): : 206 - 214
  • [34] An Integrated Security Framework For GOSS Power Grid Analytics Platform
    Gibson, Tara
    Ciraci, Selim
    Sharma, Poorva
    Allwardt, Craig
    Rice, Mark
    Akyol, Bora
    2014 44TH ANNUAL IEEE/IFIP INTERNATIONAL CONFERENCE ON DEPENDABLE SYSTEMS AND NETWORKS (DSN), 2014, : 786 - 791
  • [35] An MPC Based Algorithm for a Multipurpose Grid Integrated Solar PV System With Enhanced Power Quality and PCC Voltage Assist
    Saxena, Vardan
    Kumar, Nishant
    Singh, Bhim
    Panigrahi, Bijaya Ketan
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2021, 36 (02) : 1469 - 1478
  • [36] Efficient Method in Operational Transmission Power Grid
    Morar, Daniel
    Guzun, Basarab
    MECHANICAL, INDUSTRIAL, AND MANUFACTURING ENGINEERING, 2011, : 424 - +
  • [37] An integrated inverter with maximum power tracking for grid-connected PV systems
    Ho, BMT
    Chung, HSH
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (04) : 953 - 962
  • [38] An integrated inverter with maximum power tracking for grid-connected PV systems
    Ho, BMT
    Chung, HSH
    Hui, SYR
    APEC 2004: NINETEENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1-3, 2004, : 1559 - 1565
  • [39] On-line Frequency Security Analysis of Interconnected Power Grid Considering Inertia Adequacy and RoCoF
    Liu X.
    Li H.
    Gu X.
    Zhong W.
    Li Z.
    Shi S.
    Dianwang Jishu/Power System Technology, 2023, 47 (05): : 1780 - 1787
  • [40] Optimal planning of Renewable energy generators in modern power grid for enhanced system inertia
    Oladimeji Joseph Ayamolowo
    P. T. Manditereza
    K. Kusakana
    Technology and Economics of Smart Grids and Sustainable Energy, 7