Simulation study of medical isotope production using electron accelerator-driven photoneutron source

被引:0
|
作者
Zhang, Zixiong [1 ,2 ]
Li, Kaixuan [1 ,2 ]
Wei, Qianglin [1 ,2 ]
Liu, Yibao [1 ,2 ,3 ]
Zhang, Qintuo [1 ,2 ]
机构
[1] Engineering Research Center of Nuclear Technology Application, Ministry of Education, East China University of Technology, Nanchang,330013, China
[2] School of Nuclear Science and Engineering, East China University of Technology, Nanchang,330013, China
[3] Engineering Technology Research Center of Nuclear Radiation Detection and Application, Nanchang,330013, China
来源
He Jishu/Nuclear Techniques | 2024年 / 47卷 / 09期
关键词
Colliding beam accelerators - Electron ring accelerators - Neutron irradiation - Particle accelerator accessories - Plasma accelerators - Quality assurance - Quality control;
D O I
10.11889/j.0253-3219.2024.hjs.47.090203
中图分类号
学科分类号
摘要
[Background] Photonuclear reactions and compact neutron sources have emerged as promising tools for the production of medical isotopes, providing alternatives to conventional reactor-based high-enriched uranium methods. East China University of Technology (ECUT) is currently constructing an electron accelerator-driven photoneutron source (ECANS) for medical isotope production research. [Purpose] This study aims to investigate the photonuclear reaction with 100Mo isotope and utilize the generated neutrons for isotopic production. [Methods] Firstly, the photonuclear reactions of 100Mo was analyzed in details. The neutron spectrum and activation yield of 99Mo within a high purity 100Mo target were investigated. Then, a new model to produce medical isotopes was established on the basis of the ECANS photonuclear source, comprising neutron energy modulation layer and neutron reflection layer. Finally, the production yields of 99Mo, 177Lu, and 90Y in various natural oxides were calculated and the feasibility of using photonuclear sources for medical isotope production was assessed. The content of radioactive impurities in natural oxides under irradiation conditions was also analyzed. [Results] Simulation results demonstrate that photo-nuclear reactions can effectively produce medical isotopes such as 99Mo, 177Lu, and 90Y, with respective activities of 0.64 TBq·d−1, 0.67 TBq·d−1, and 2.11 TBq·d−1. And in the high purity 100Mo target, the daily output of 99Mo reaches 2.00 TBq·d−1. [Conclusions] This study demonstrates the feasibility of using the photodisintegration reaction of 100Mo as a neutron source for secondary production of medical isotopes, offering the potential to enhance the economic viability of isotope production. The approach of this study provides preliminary insights for subsequent separation and purification processes, hence has certain reference value for the development of tools for radioactive isotope production. © 2024 Science Press. All rights reserved.
引用
收藏
相关论文
共 50 条
  • [21] Evidence of source dominance in the dynamic behavior of accelerator-driven systems
    Rydin, RA
    Woosley, ML
    NUCLEAR SCIENCE AND ENGINEERING, 1997, 126 (03) : 341 - 344
  • [22] Subcritical multiplication factor and source efficiency in accelerator-driven system
    Shahbunder, Hesham
    Pyeon, Cheol Ho
    Misawa, Tsuyoshi
    Lim, Jae-Yong
    Shiroya, Seiji
    ANNALS OF NUCLEAR ENERGY, 2010, 37 (09) : 1214 - 1222
  • [23] Performance of an electron linear accelerator for the first photoneutron source in China
    Xuan Li
    Jun-Qiang Zhang
    Guo-Qiang Lin
    Wen-Cheng Fang
    Qiang Gu
    Meng Zhang
    NuclearScienceandTechniques, 2019, 30 (04) : 3 - 9
  • [24] Performance of an electron linear accelerator for the first photoneutron source in China
    Li, Xuan
    Zhang, Jun-Qiang
    Lin, Guo-Qiang
    Fang, Wen-Cheng
    Gu, Qiang
    Zhang, Meng
    NUCLEAR SCIENCE AND TECHNIQUES, 2019, 30 (04)
  • [25] Target and shielding design of accelerator-driven transportable neutron source
    Kushima, Yusuke
    Kobayashi, Tomohiro
    Ikeda, Yujiro
    Hayashizaki, Noriyosu
    Hagura, Naoto
    Kawarabayashi, Jun
    Otake, Yoshie
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [26] Source efficiency as function of fuel and coolant in accelerator-driven systems
    Westlen, Daniel
    Seltborg, Per
    ANNALS OF NUCLEAR ENERGY, 2006, 33 (09) : 829 - 836
  • [27] Water Corrosion of Tungsten Target for Accelerator-Driven Neutron Source
    Xie, Yupeng
    Sun, Qiuyu
    Hu, Yaocheng
    Li, Xiaobo
    Qiao, Zhaopeng
    Wang, Jie
    Wang, Sheng
    MATERIALS, 2022, 15 (10)
  • [28] A novel method for designing the moderator of accelerator-driven neutron source
    Hu, Guang
    Ren, Yanyan
    Cui, Rongrong
    Chu, Qianqian
    ANNALS OF NUCLEAR ENERGY, 2019, 133 : 96 - 99
  • [29] Beam dynamics design for a compact accelerator-driven neutron source
    Li, Haipeng
    Gan, Pingping
    Fu, Qi
    Tan, Qiuyun
    Lu, Yuanrong
    Wang, Zhi
    Zhu, Kun
    Easton, Matt
    INTERNATIONAL JOURNAL OF MODERN PHYSICS E-NUCLEAR PHYSICS, 2018, 27 (04)
  • [30] Study on the edge-cooling target structure for transportable accelerator-driven neutron source
    Li, Xiaobo
    Ikeda, Yujiro
    Kobayashi, Tomohiro
    Wang, Sheng
    Otake, Yoshie
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1017 (1017):