ESTIMATION FOR ENERGY SAVING EFFECT BY OPERATION CONTROL OF COOLING WATER SYSTEM IN AN OFFICE BUILDING WITH MULTIPLE HEAT SOURCES

被引:0
|
作者
Ueno T. [1 ]
Yamazaki Y. [2 ]
Yoshida S. [2 ]
Sato K. [3 ]
Sawachi T. [4 ]
机构
[1] Faculty of Environmental Engineering, The Univ. of Kitakyushu
[2] Yokohama Warehouse Co., Ltd.
来源
关键词
BEMS; Cooling; Cooling Tower; Cross-flow type; Office building;
D O I
10.3130/aije.89.358
中图分类号
学科分类号
摘要
This paper describes the analysis of cooling operation for an office building with multiple air-conditioning heat sources and cooling water systems. It also evaluated the energy-saving impact of further optimizing the cooling water system operation. 1. BEMS data of the office building was analyzed to reveal the cooling water system operation in the cooling of the air-conditioning heat source. Furthermore, characteristic equations for cooling water pump were created. 2. A study using simulation models incorporating cooling water systems and heat sources confirmed that more energy-saving potential from lowering the cooling water temperature and expanding the free cooling period. © 2024 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:358 / 367
页数:9
相关论文
共 50 条
  • [21] Detailed analysis on part load ratio characteristics and cooling energy saving of chiller staging in an office building
    Seo, Byeong Mo
    Lee, Kwang Ho
    ENERGY AND BUILDINGS, 2016, 119 : 309 - 322
  • [22] The energy saving control of air condition system in intelligent building
    Liu, ZJ
    Xie, WL
    Huang, YL
    PROCEEDINGS OF THE 4TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-4, 2002, : 2240 - 2243
  • [23] Ground source heat pump and conventional heat sources to match the design and operation mode for energy saving
    Ran, Chunyu
    Zhang, Liyun
    ADVANCED RESEARCH ON MATERIAL, ENERGY AND CONTROL ENGINEERING, 2013, 648 : 189 - 193
  • [24] Ground Source Heat Pump And Conventional Heat Sources To Match The Design And Operation Mode For Energy Saving
    Sun, Lei
    Xiao, Jiafu
    Ran, Chunyu
    Zhang, Liyun
    APPLIED ENERGY TECHNOLOGY, PTS 1 AND 2, 2013, 724-725 : 955 - +
  • [25] Research on Control Strategy of General Control System for Building Cold and Heat Sources Based on Energy Internet
    Chen Feng
    Meng Qingda
    Yang Guang
    Zuo Zhuang
    Zhang Xin
    Zhang Shicong
    Liu Weinan
    PROCEEDINGS OF THE 30TH CHINESE CONTROL AND DECISION CONFERENCE (2018 CCDC), 2018, : 5090 - 5095
  • [26] Feasibility study of a water-to-air heat pipe based heat exchanger for cooling load reduction and energy saving in the office buildings: A simulation study
    Ahmadzadehtalatapeh, M.
    SCIENTIA IRANICA, 2017, 24 (03) : 1040 - 1050
  • [27] Research of Energy Optimal Operation on Building Cooling Heating and Power System
    Ma, Jingchao
    Chang, Dezheng
    Xu, Xiaoguang
    Wang, Zhe
    CURRENT DEVELOPMENT OF MECHANICAL ENGINEERING AND ENERGY, PTS 1 AND 2, 2014, 494-495 : 1606 - 1610
  • [28] Energy-saving potential of a novel ventilation system with decentralised fans in an office building
    Gunner, Amalie
    Hultmark, Goran
    Vorre, Anders
    Afshari, Alireza
    Bergsoe, Niels Christian
    ENERGY AND BUILDINGS, 2014, 84 : 360 - 366
  • [29] Analysis on energy-saving of natural cooling chilled water system
    Fang, Zhen
    Hu, Chuntao
    Liu, Qian
    He, Ping
    2022 9TH INTERNATIONAL FORUM ON ELECTRICAL ENGINEERING AND AUTOMATION, IFEEA, 2022, : 289 - 294
  • [30] Building energy saving of a rotatable radiative cooling-photovoltaic system by alternate utilization of solar energy and radiative cooling
    Tang, Haida
    Wu, Juhu
    Chen, Weijie
    Li, Chunying
    ENERGY AND BUILDINGS, 2024, 316