Supplementary Comparison on Calibration of Dial Gauge

被引:0
|
作者
ElMelegy, Ahmed [1 ]
机构
[1] Giza, Egypt
关键词
Indicators (instruments) - Instrument dials - Strain measurement - Velocity measurement;
D O I
暂无
中图分类号
学科分类号
摘要
National Metrology Institutes from 8 African countries, namely Egypt, Nigeria, Kenya, Tanzania, Zambia, Zimbabwe, Botswana, and Mauritius have participated in an international supplementary comparison on the calibration of Dial Indicators. This comparison was a part of larger supplementary comparison between 13 African countries for the calibration of hand measuring instruments. This larger comparison which was carried out during the period between December 2019 – December 2022 has been piloted by NIS, Egypt and has been registered in BIPM-KCDB database on December 2019 with the identifier AFRIMETS.L-S5. The artifacts have been prepared by NIS, Egypt and measured before sent to circulate between all participant countries in round-robin scheme and returned back again for NIS, Egypt where a final measurement was made for stability check. The main purpose of these comparisons is to support submission of CMCs for calibration of hand length measuring instruments in BIPM-KCDB. © 2024 Institute of Physics. All rights reserved.
引用
收藏
相关论文
共 50 条
  • [41] AN IMPROVED GAUGE CALIBRATION TECHNIQUE
    LANGE, WJ
    ERIKSEN, DP
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1966, 3 (05): : 303 - &
  • [42] AN IMPROVED GAUGE CALIBRATION TECHNIQUE
    LANGE, WJ
    ERIKSEN, DP
    VACUUM, 1967, 17 (03) : 164 - +
  • [43] SOME ERRORS IN GAUGE CALIBRATION
    CLAKE, PJ
    VACUUM, 1967, 17 (03) : 164 - &
  • [44] Supplementary comparison of national measurement standards of gauge pressure in the range from 1 MPa to 10 MPa
    Zuyev, A.
    Bardonov, A.
    Leontyev, M.
    Dapkeviciene, K.
    Metrologia, 2024, 61 (1 A)
  • [45] ULTRAHIGH VACUUM GAUGE CALIBRATION
    DAVIS, WD
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1968, 5 (01): : 23 - &
  • [46] VACUUM MEASUREMENTS AND GAUGE CALIBRATION
    CALCATELLI, A
    VACUUM, 1989, 39 (7-8) : 799 - 807
  • [47] CALIBRATION OF AN AORTIC CIRCUMFERENCE GAUGE
    LAWTON, RW
    COLLINS, CC
    JOURNAL OF APPLIED PHYSIOLOGY, 1959, 14 (03) : 465 - 467
  • [48] SOME ERRORS IN GAUGE CALIBRATION
    CLAKE, PJ
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1966, 3 (05): : 303 - &
  • [49] Calibration of manometers for gauge pressure
    Jitschin, Wolfgang
    VAKUUM IN FORSCHUNG UND PRAXIS, 2009, 21 (04) : 11 - 15
  • [50] Report on Gulfmet supplementary comparison measurement of gauge blocks by interferometry (GULFMET.L-S2)
    Sendogdu, D.
    Yaman, O.
    Cetin, T.
    Hamid, R.
    Sahin, E.
    Senel, C.
    Asar, M.
    Alqahtani, N.
    Alqahtani, F.
    Talhh, Y. B.
    Almutari, A.
    METROLOGIA, 2019, 56 (1A)