Supplementary Comparison on Calibration of Dial Gauge

被引:0
|
作者
ElMelegy, Ahmed [1 ]
机构
[1] Giza, Egypt
关键词
Indicators (instruments) - Instrument dials - Strain measurement - Velocity measurement;
D O I
暂无
中图分类号
学科分类号
摘要
National Metrology Institutes from 8 African countries, namely Egypt, Nigeria, Kenya, Tanzania, Zambia, Zimbabwe, Botswana, and Mauritius have participated in an international supplementary comparison on the calibration of Dial Indicators. This comparison was a part of larger supplementary comparison between 13 African countries for the calibration of hand measuring instruments. This larger comparison which was carried out during the period between December 2019 – December 2022 has been piloted by NIS, Egypt and has been registered in BIPM-KCDB database on December 2019 with the identifier AFRIMETS.L-S5. The artifacts have been prepared by NIS, Egypt and measured before sent to circulate between all participant countries in round-robin scheme and returned back again for NIS, Egypt where a final measurement was made for stability check. The main purpose of these comparisons is to support submission of CMCs for calibration of hand length measuring instruments in BIPM-KCDB. © 2024 Institute of Physics. All rights reserved.
引用
收藏
相关论文
共 50 条
  • [1] Supplementary comparison - calibration of gauge blocks by mechanical method
    Angnostou M.
    Dahlan A.
    Alsenaidi M.
    Yandayan T.
    Akgoz S.A.
    Halim R.M.
    AlQahtani N.
    AlQahtani F.
    Talha Y.B.
    AlMathkor F.
    Habibi S.
    Metrologia, 2023, 60 (1A)
  • [2] Study of automatic calibration method of dial gauge
    Yu, ZL
    Zhang, LZ
    Jiang, T
    Su, CZ
    ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 2047 - 2050
  • [3] Supplementary comparison EURAMET.L-S22, calibration of gauge blocks by mechanical comparison
    Lewis, Andrew
    Lillepea, Lauri
    Matus, Michael
    Prieto, Emilio
    Acko, Bojan
    Hansen, Maria Svendsmark
    Turner, Paul
    Testa, Nicola
    Daoud, Anouar
    Montassar, Chekir
    METROLOGIA, 2017, 54
  • [4] Supplementary Comparison on Calibration of Feeler gauges
    ElMelegy, Ahmed
    Metrologia, 2024, 61
  • [5] APMP Supplementary Comparison APMP.L-S3 Calibration of gauge blocks by mechanical comparison Final Report
    Drijarkara, Praba
    Kang, Chu-Shik
    METROLOGIA, 2012, 49
  • [6] Final report on EUROMET supplementary comparison EUROMET.L-S12: Calibration of gauge blocks by mechanical comparison
    McQuoid, Howard
    Ramotowski, Zbigniew
    METROLOGIA, 2008, 45
  • [7] Calibration system for dial gauges
    Hermann, Gyula
    SACI 2007: 4th International Symposium on Applied Computational Intelligence and Informatics, Proceedings, 2007, : 41 - 43
  • [8] EURAMET supplementary comparison on calibration of RF current monitoring probe
    Sen, O.
    Cinar, M.
    Kriz, A.
    Pavlicek, T.
    Lerat, J. M.
    Wojciechowski, M.
    Pinter, B.
    Rodriguez, M.
    Pythoud, F.
    METROLOGIA, 2021, 58 (1A)
  • [9] PRACTICAL LIMITATIONS OF THE DIAL GAUGE DENDROMETER
    YOUNG, HE
    ECOLOGY, 1952, 33 (04) : 568 - 570
  • [10] Issues and advantages of gauge block calibration by mechanical comparison
    Thalmann, R
    Baechler, H
    RECENT DEVELOPMENTS IN TRACEABLE DIMENSIONAL MEASUREMENTS II, 2003, 5190 : 62 - 69