Effect of Preloading on Strain Ratio Measurement: A Phantom Study Using Real-time Tissue Elastography

被引:0
|
作者
Yamada, Daichi [1 ,2 ]
Tanaka, Noriko [1 ,3 ]
Koshino, Yaemi [1 ,3 ]
Koyanagi, Maki [1 ,3 ]
机构
[1] Faculty of Biomedical Engineering, Osaka Electro-Communication University Graduate School, Japan
[2] Department of Rehabilitation, Osaka University Hospital, Japan
[3] Faculty of Health Science, Osaka Electro-Communication University, Japan
关键词
Medical imaging - Phantoms - Stiffness - Tendons;
D O I
10.11239/jsmbe.62.65
中图分类号
学科分类号
摘要
Decreased tendon stiffness is considered to be a factor in the progression of tendon injury, and research is ongoing to develop methods for quantitatively assessing tendon stiffness. Strain ratio (SR) measurement using the strain elastography function of an ultrasound diagnostic device can noninvasively measure the stiffness of living tissue based on the ratio of strain values between the acoustic coupler and the measured material, and thus can be used to assess the stiffness of tendons. However, the reliability of such measurements remains an issue. Therefore, the purpose of this study was to clarify the influence of preloading on the SR measurement of a phantom mimicking a tendon with decreased stiffness. Independent inclusions with stiffness values of 100, 200, and 400 kPa were placed in the phantom and measured. Preloading was set to 0.5, 1.0, and 1.5 N, and the SR was measured by applying an mechanically controlled additional load of 3.0 N. Taking the average of three measurements for each inclusion as a representative value, three sets of measurements were performed on different days for each preloading condition. The intraclass correlation coefficient (ICC) was used to examine the intra-observer reliability between days. In addition, the SR among preloading conditions was compared. ICC (1, 1) was 0.99 for all preloading conditions, indicating excellent reliability. The comparison among preloading conditions showed that the SR significantly decreased at a preloading of 1.5 N compared with 0.5 N for all inclusions. These results suggest the importance of controlling preloading during SR measurements. © 2024, Japan Soc. of Med. Electronics and Biol. Engineering. All rights reserved.
引用
收藏
页码:65 / 70
相关论文
共 50 条
  • [31] NON-INVASIVE EVALUATION OF HEPATIC TUMORS USING REAL-TIME TISSUE ELASTOGRAPHY
    Nakao, H.
    Nakade, Y.
    Sato, K.
    Ohashi, T.
    Tsunekawa, A.
    Kanamori, H.
    Yamamoto, T.
    Banno, F.
    Yoneda, M.
    JOURNAL OF HEPATOLOGY, 2011, 54 : S395 - S395
  • [32] Tissue Doppler optical coherence elastography for real time strain rate and strain mapping of soft tissue
    Wang, Ruikang K.
    Ma, Zhenhe
    Kirkpatrick, Sean J.
    APPLIED PHYSICS LETTERS, 2006, 89 (14)
  • [33] USEFULNESS OF REAL-TIME ELASTOGRAPHY STRAIN RATIO IN THE ASSESSMENT OF BILE DUCT LIGATION-INDUCED LIVER INJURYAND THE HEPATOPROTECTIVE EFFECT OF CHITOSAN: AN EXPERIMENTAL ANIMAL STUDY
    Dudea, Marina
    Clichici, Simona
    Olteanu, Diana Elena
    Nagy, Andras
    Cucos, Maria
    Dudea, Sorin
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (01): : 114 - 123
  • [34] Value of Real-Time and Strain Ratio Elastography in Differential Diagnosis of Graves' Disease and Subacute and Hashimoto's Thyroiditis
    Korkmaz, Hatice Ayca Ata
    Baki, Gaye
    Kose, Mustafa
    Cobanoglu, Bengu Yaldiz
    IRANIAN JOURNAL OF RADIOLOGY, 2017, 14 (04)
  • [35] Can real-time ultrasound elastography using the color score and strain ratio differentiate between benign and malignant solitary thyroid nodules?
    Refaat, Rania
    Kamel, Amr
    Elganzory, Mahmoud
    Awad, Nahla M.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2014, 45 (01): : 75 - 87
  • [36] Real-Time Nondestructive Viscosity Measurement of Soft Tissue Based on Viscoelastic Response Optical Coherence Elastography
    Liu, Zhixin
    Liu, Weidong
    Chen, Qi
    Hu, Yongzheng
    Li, Yurun
    Zheng, Xiaoya
    Fang, Dian
    Liu, Hai
    Sun, Cuiru
    MATERIALS, 2023, 16 (17)
  • [37] Noninvasive evaluation of hepatic fibrosis using serum fibrotic markers, transient elastography (FibroScan) and real-time tissue elastography
    Tatsumi, Chie
    Kudo, Masatoshi
    Ueshima, Kazuomi
    Kitai, Satoshi
    Takahashi, Shunsuke
    Inoue, Tatsuo
    Minami, Yasunori
    Chung, Hobyung
    Maekawa, Kiyoshi
    Fujimoto, Kenji
    Akiko, Tonomura
    Takeshi, Mitake
    INTERVIROLOGY, 2008, 51 : 27 - 33
  • [38] Real-time measurement of internal stress of dental tissue using holography
    Pantelic, Dejan
    Blazic, Larisa
    Savic-Sevic, Svetlana
    Muric, Branka
    Vasiljevic, Darko
    Panic, Bratimir
    Belic, Ilija
    OPTICS EXPRESS, 2007, 15 (11) : 6823 - 6830
  • [39] Effect of diet on the measurement of liver elasticity by real-time shear wave elastography in normal subjects
    Ding, Jin
    Li, Li
    Xue, Hong-Yuan
    FOOD SCIENCE AND TECHNOLOGY, 2022, 42
  • [40] PROSTATE CANCER DETECTION USING REAL-TIME TISSUE ELASTOGRAPHY IN PATIENTS WITH LOWER PSA LEVELS
    Sumura, Masahiro
    Anjiki, Haruki
    Kobara, Chiaki
    Inoue, Keita
    Arichi, Naoko
    Mitsui, Yozo
    Hiraoka, Takeo
    Honda, Satoshi
    Yasumoto, Hiroaki
    Shiina, Hiroaki
    Yoshizako, Takeshi
    Kitagaki, Hajime
    Igawa, Mikio
    JOURNAL OF UROLOGY, 2012, 187 (04): : E660 - E660