Gait Analysis of Knee Joint Walking Based on Image Processing

被引:0
|
作者
Wang S. [1 ,2 ]
Zhou J. [2 ,3 ]
机构
[1] School of Physical Education, Shanxi University, Shanxi, Taiyuan
[2] School of Sports Medicine and Health, Chengdu Sport University, Sichuan, Chengdu
[3] Sichuan China 81 Rehabilitation Center (Sichuan Provincial Rehabilitation Hospital), Sichuan, Chengdu
关键词
Gait analysis; Image processing; Patients; Thigh amputee; Walking at knee joint; Wearing artificial limb;
D O I
10.2174/0115734056277482240329050639
中图分类号
学科分类号
摘要
Background: With the in-depth development of assistive treatment devices, the application of artificial knee joints in the rehabilitation of amputees is becoming increasingly mature. The length of residual limbs and muscle strength of patients have individual differences, and the current artificial knee joint lacks certain adaptability in the personalized rehabilitation of patients. Purpose: In order to deeply analyze the impact of different types of artificial knee joints on the walking function of unilateral thigh amputees, improve the performance of artificial knee joints, and enhance the rehabilitation effect of patients, this article combines image processing technology to conduct in-depth research on the walking gait analysis of different artificial knee joints of unilateral thigh amputees. Methods: This article divides patients into two groups: the experimental group consists of patients with single leg amputation, and the control group consists of patients with different prostheses. An image processing system is constructed using universal video and computer hardware, and relevant technologies are used to recognize and track landmarks; Furthermore, image processing technology was used to analyze the gait of different groups of patients. Finally, by analyzing the different psychological reactions of amputees, corresponding treatment plans were developed. Results: Different prostheses worn by amputees have brought varying degrees of convenience to life to a certain extent. The walking stability of wearing hydraulic single axis prosthetic joints is only 79%, and the gait elegance is relatively low. The walking stability of wearing intelligent artificial joints is as high as 96%. Elegant gait is basically in good condition. Conclusion: Image processing technology helps doctors and rehabilitation practitioners better understand the gait characteristics and rehabilitation progress of patients wearing different artificial knee joints, providing objective basis for personalized rehabilitation of patients. © 2024 The Author(s).
引用
下载
收藏
相关论文
共 50 条
  • [31] Preliminary study on verifying the detection of gait intention based on knee joint anterior displacement of gait slopes
    Yu, Changho
    Kang, Seung Rok
    Yang, Giltae
    Hong, Chul Un
    Lee, Hyung Jong
    Oh, Do Young
    Kwon, Tae Kyu
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S583 - S592
  • [32] The Role of Knee Joint in Passive Dynamic Walking
    JongRok Lee
    Junhyuk Yang
    Kiwon Park
    International Journal of Precision Engineering and Manufacturing, 2025, 26 (2) : 415 - 427
  • [33] A gait transition algorithm based on hybrid walking gait for a quadruped walking robot
    Lee, Yoon Haeng
    Duc Trong Tran
    Hyun, Jae-ho
    Luong Tin Phan
    Koo, Ig Mo
    Yang, Seung Ung
    Choi, Hyouk Ryeol
    INTELLIGENT SERVICE ROBOTICS, 2015, 8 (04) : 185 - 200
  • [34] MECHANICS OF KNEE JOINT IN RELATION TO NORMAL WALKING
    MORRISON, JB
    JOURNAL OF BIOMECHANICS, 1970, 3 (01) : 51 - &
  • [35] A gait transition algorithm based on hybrid walking gait for a quadruped walking robot
    Yoon Haeng Lee
    Duc Trong Tran
    Jae-ho Hyun
    Luong Tin Phan
    Ig Mo Koo
    Seung Ung Yang
    Hyouk Ryeol Choi
    Intelligent Service Robotics, 2015, 8 : 185 - 200
  • [36] Design and simulation of a virtual walking machine based on gait analysis
    Yoon, J
    Ryu, J
    Lim, KB
    Na, YM
    IASTED: PROCEEDINGS OF THE IASTED INTERNATIONAL CONFERENCE ON ROBOTICS AND APPLICATIONS, 2003, : 82 - 87
  • [37] Biped Walking Stabilization on Soft Ground Based on Gait Analysis
    Kang, Hyun-jin
    Hashimoto, Kenji
    Nishikawa, Kosuke
    Falotico, Egidio
    Lim, Hun-ok
    Takanishi, Atsuo
    Laschi, Cecilia
    Dario, Paolo
    Berthoz, Alain
    2012 4TH IEEE RAS & EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2012, : 669 - 674
  • [38] Multifactorial estimation of hip and knee joint centres for clinical application of gait analysis
    Frigo, C
    Rabuffetti, M
    GAIT & POSTURE, 1998, 8 (02) : 91 - 102
  • [39] Kinematic approach to gait analysis in patients with rheumatoid arthritis involving the knee joint
    Sakauchi, M
    Narushima, K
    Sone, H
    Kamimaki, Y
    Yamazaki, Y
    Kato, S
    Takita, T
    Suzuki, N
    Moro, K
    ARTHRITIS & RHEUMATISM-ARTHRITIS CARE & RESEARCH, 2001, 45 (01): : 35 - 41
  • [40] Gait Analysis based Speed Control of Walking Assistive Robot
    Fujimoto, Akane
    Matsumoto, Naoya
    Jiang, Yinlai
    Togo, Shunta
    Teshigawara, Seiichi
    Yokoi, Hiroshi
    2018 IEEE INTERNATIONAL CONFERENCE ON INTELLIGENCE AND SAFETY FOR ROBOTICS (ISR), 2018, : 88 - 92