A Simple High-Sensitivity Sensor Based on Multimode Mach-Zehnder Interference for Refractive Index Measurement

被引:1
|
作者
Wu, Yupeng [1 ]
Wang, Qianjin [2 ]
Li, Yuxin [2 ]
Li, Miao [2 ]
Pan, Meiting [2 ]
Zhou, Xue [3 ]
Yan, Xin [4 ]
Zhao, Yong [5 ]
Cheng, Tonglei [6 ]
机构
[1] Shenyang Aerosp Univ, Elect Informat Engn, Shenyang, Peoples R China
[2] Northeastern Univ, Shenyang, Peoples R China
[3] Shenyang Jianzhu Univ, Coll Informat & Control Engn, Shenyang, Peoples R China
[4] Jilin Univ, Changchun, Peoples R China
[5] Harbin Inst Technol, Harbin, Peoples R China
[6] Tianjin Univ, Opt Engn, Tianjin, Peoples R China
基金
中国国家自然科学基金;
关键词
Femtosecond laser; high sensitivity; Mach-Zehnder interferometer (MZI); refractive index (RI); INTERFEROMETER; TEMPERATURE;
D O I
10.1109/JSEN.2024.3447270
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The present study proposes and experimentally verifies a refractive index (RI) sensor with high sensitivity and simple structure based on multimode Mach-Zehnder interference, in which a suspend-core fiber (SCF) fused with single-mode fibers (SMFs) at both ends worked as the sensing unit. Femtosecond laser is used to process SCF, forming microfluidic channels for liquid in and out, and then, encapsulation is conducted to enhance the mechanical characteristics of the Mach-Zehnder interferometer (MZI) sensor. By analyzing simulation and experimental results, it has been confirmed that the multimode MZI arises from the effective RI difference between the fundamental mode and the higher order modes of the SCF core induced by RI variations of external environment. This study involves the preparation and testing of three sensors with varying SCF lengths. As the external RI varies in the range of 1.3333-1.3472, all sensors exhibit sensitivities at a comparable level. This observation aligns well with the theoretical analysis, indicating that fiber length does not have direct impact on the sensing performance. The maximum sensitivity was 1825.41 nm/RIU. The three sensors undergo tests to assess their repeatability and stability, revealing a maximum wavelength error of 0.1975 nm for repeatability and 0.18 nm for stability. In addition, the temperature sensitivity within the range of 20 degrees C-100 degrees C is found to be as low as 0.00667 nm/degrees C, indicating that the potential impact of temperature-induced wavelength shift can be disregarded. The sensor exhibits high sensitivity, excellent repeatability, and stability, promising extensive application in diverse fields, including biology, chemistry, medicine, and environmental monitoring.
引用
收藏
页码:30161 / 30167
页数:7
相关论文
共 50 条
  • [31] Dumbbell-Shaped Mach-Zehnder Interferometer With High Sensitivity of Refractive Index
    Wen, Xiaodong
    Ning, Tigang
    You, Haidong
    Li, Jing
    Feng, Ting
    Pei, Li
    Jian, Wei
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2013, 25 (18) : 1839 - 1842
  • [32] A Bent In-Line Mach-Zehnder Interferometer Sensor to Increase Refractive Index Sensitivity
    da Silveira, Clenilson Rodrigues
    Wey, Joao Crisostomo
    Costa, Albuquerque
    Rocco Giraldi, Maria Thereza
    Ruggieri Franco, Marcos Antonio
    da Silva Jorge, Pedro Alberto
    2013 SBMO/IEEE MTT-S INTERNATIONAL MICROWAVE & OPTOELECTRONICS CONFERENCE (IMOC), 2013,
  • [33] Simultaneous measurement of refractive index and temperature using multimode microfiber-based dual Mach-Zehnder interferometer
    Luo, Haipeng
    Sun, Qizhen
    Xu, Zhilin
    Liu, Deming
    Zhang, Lin
    OPTICS LETTERS, 2014, 39 (13) : 4049 - 4052
  • [34] Mach-Zehnder Interferometer on the Base of Gradient Index Multimode Interference Structures
    Blahut, M.
    Kasprzak, D.
    Sujewicz, M.
    ACTA PHYSICA POLONICA A, 2009, 116 (03) : 261 - 263
  • [35] Refractive index and temperature sensor based on Mach-Zehnder interferometer with thin fibers
    Liu, Wei
    Wu, Xuqiang
    Zhang, Gang
    Li, Shili
    Zuo, Cheng
    Fang, Shasha
    Yu, Benli
    OPTICAL FIBER TECHNOLOGY, 2020, 54
  • [36] A Hybrid Mach-Zehnder Interferometer for Refractive Index and Temperature Measurement
    Ni, Xiaoqi
    Wang, Ming
    Guo, Dongmei
    Hao, Hui
    Zhu, Jiali
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2016, 28 (17) : 1850 - 1853
  • [37] High-sensitivity refractive index multimode fibre sensor based on a silica capillary
    Freitas, Ana I.
    Bierlich, Joerg
    Ferreira, Marta S.
    OPTICAL SENSING AND DETECTION VIII, 2024, 12999
  • [38] Refractive index sensor using microfiber-based Mach-Zehnder interferometer
    Wo, Jianghai
    Wang, Guanghui
    Cui, Ying
    Sun, Qizhen
    Liang, Ruibing
    Shum, Perry Ping
    Liu, Deming
    OPTICS LETTERS, 2012, 37 (01) : 67 - 69
  • [39] Mach-Zehnder Interferometer Refractive Index Sensor Based on a Plasmonic Channel Waveguide
    Lee, Da Eun
    Lee, Young Jin
    Shin, Eunso
    Kwon, Soon-Hong
    SENSORS, 2017, 17 (11):
  • [40] Mach-Zehnder Based on Large Knot Fiber Resonator for Refractive Index Measurement
    Gomes, Andre D.
    Frazao, Orlando
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2016, 28 (12) : 1279 - 1281