Moisture and Aging Degree Evaluation Method for Oil-Paper Insulation Based on HV-FDS Characteristics Analysis

被引:0
|
作者
Shi S. [1 ]
Hao J. [1 ]
Zeng Q. [1 ]
Yin F. [2 ]
Liao R. [1 ]
机构
[1] School of Electrical Engineering, State Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing
[2] Shenzhen International Graduate School, Institute of Advanced Technologies in Energy and Electrical Engineering (IAT3E), Tsinghua University, Shenzhen, Guangdong
关键词
Aging; Dielectric liquids; Dielectrics; evaluation method; HV-FDS; Insulation; Minerals; Moisture; Oils; Power transformer; liquid-solid” oil-paper insulation;
D O I
10.1109/TDEI.2024.3394401
中图分类号
学科分类号
摘要
Oil-paper insulation is the &#x201C;heart&#x201D; of power transformer, and frequency domain spectroscopy (FDS) is an efficient method to evaluate the insulation state of it. Nevertheless, traditional FDS test voltage is still at 200 V, the insulation characteristics of FDS at high voltage levels are worth exploring. Therefore, this paper studies the FDS characteristics of oil-paper insulation at various test voltage and proposed an evaluation method of moisture and aging degree of oil-immersed pressboard based on high voltage FDS. The results show with the increase of test voltage, the <italic>C</italic>&#x2019; of mineral oil increases from 1 mHz to 10 Hz while of oil-immersed pressboard and &#x201C;liquid-solid&#x201D; oil-paper insulation decreases below 10 Hz; <italic>tan</italic>&#x03B4; of all samples increases significantly with the increase of test voltage. The <italic>tan</italic>&#x03B4; at 0.1, 1 and 10 Hz is selected as characteristic parameter to evaluate the moisture content of oil-immersed pressboard, <italic>tan</italic>&#x03B4; at high voltage is more sensitive to moisture content compared with that at low voltage, <italic>tan</italic>&#x03B4; at 0.1 Hz and 7000 V increases 1130 times compared 75 times at 0.1 Hz and 200 V. The integral of <italic>tan</italic>&#x03B4;, <italic>S</italic><italic>tan</italic>&#x03B4;, from 0.1 Hz to 10 Hz is selected as parameters to evaluate the aging degree. The oil-immersed pressboard and distribution transformer are tested and evaluated by above evaluation method, and the results show that the error of moisture content and aging degree evaluation result is less than 10%. IEEE
引用
收藏
页码:1 / 1
相关论文
共 50 条
  • [21] The Investigation on Thermal Aging Characteristics of Oil-Paper Insulation in Bushing
    Liao, Rui-jin
    Hu, En-de
    Yang, Li-jun
    Xu, Zuo-ming
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2015, 10 (03) : 1114 - 1123
  • [22] Electrical Aging Characteristics of Natural Ester Oil-paper Insulation Respectively Considering Temperature and Moisture
    Chen, Xiuping
    Li, Jian
    Lv, Yandong
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [23] Dielectric response characteristics and moisture exposure evaluation of oil-paper insulation based on microstrip ring resonator
    Xu, Lulin
    Zhang, Daning
    Jiang, Jiongting
    Mu, Haibao
    Zhang, Guanjun
    MEASUREMENT, 2024, 234
  • [24] Effects of oil and paper aging state on space charge characteristics in oil-paper insulation
    Zhou Y.
    Zhang X.
    Huang X.
    Wang H.
    Xue L.
    Zhongguo Kexue Jishu Kexue/Scientia Sinica Technologica, 2023, 53 (04): : 589 - 600
  • [25] A Modified Simulation Model for Predicting the FDS of Transformer Oil-Paper Insulation Under Nonuniform Aging
    Liu, Jiefeng
    Sun, Tengyue
    Fan, Xianhao
    Zhang, Yiyi
    Lai, Benhui
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [26] The Relationship between Carbon Oxides in Oil and Thermal Aging Degree of Oil-paper Insulation
    Fu, Qiang
    Wang, Mengjun
    Chen, Tiansheng
    Li, Xudong
    Li, Jian
    Zhang, Jing
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [27] Influence of Cellulose Aging on the Equilibrium Moisture Content Estimation of Oil-paper Insulation
    Wang D.
    Zhou L.
    Liu W.
    Pan G.
    Guo L.
    Xu X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2018, 38 (06): : 1889 - 1894
  • [28] Aging Lifetime Evaluation of Transformer Oil-paper Insulation Considering Oil Replacement
    Liu J.
    Lü J.
    Zhang M.
    Jia H.
    Nie H.
    Wei X.
    Gaodianya Jishu/High Voltage Engineering, 2020, 46 (05): : 1750 - 1758
  • [29] Aging and moisture evaluation characteristic parameters for oil-paper insulation of transformer using frequency dielectric spectroscopy
    Wang, Youyuan
    Gao, Jun
    Liu, Jiefeng
    Zhang, Yiyi
    Hao, Jian
    Ma, Zhiqin
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2015, 30 (22): : 215 - 221
  • [30] Insulation aging characteristics of transformer oil-paper by multi-parameter regression analysis
    Han, Hui-Hui
    Yang, Dao-Wu
    Wang, Su
    Li, Zhe-Wen
    Li, Hai-Ru
    Ren, Zhuo
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (12): : 2937 - 2941