Interface Fatigue Test of Hybrid-Bonded Fiber-Reinforced Plastic-Reinforced Concrete Specimen

被引:0
|
作者
Zhou, Kun [1 ]
Wei, Qian [2 ]
Wang, Jiabin [3 ]
Gao, Lei [2 ]
Dong, Chao [3 ]
Zhang, Zejun [3 ]
Fu, Kunhao [3 ]
Cheng, Ziqin [4 ]
机构
[1] Shandong Hispeed Construct Management Grp Co Ltd, Jinan 250014, Peoples R China
[2] Shandong Univ, Geotech & Struct Engn Res Ctr, Jinan 250061, Peoples R China
[3] Shandong Hispeed Yanpeng Highway Co Ltd, Weihai 265800, Peoples R China
[4] Shandong High Speed Grp Co Ltd, Innovat Res Inst, Jinan 250098, Peoples R China
关键词
FRP; fatigue property; interfaces property; bond-slip relationship; FRP; PREDICTION;
D O I
10.3390/buildings14103080
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This research produced five hybrid-bonded fiber-reinforced plastic (HB-FRP)-reinforced beam specimens, and different fatigue load amplitudes were used as parameter variables for the fatigue performance tests of the FRP-concrete interface. The results show that FRP sliding with the number of cycles can be roughly divided into fatigue initiation stage, fatigue development stage, and fatigue damage stage, and finally, because the load is too large and friction, pin, and bonding cannot provide a greater inhibition effect, FRP adhesive length is not enough to withstand the stripping load and failure. FRP slip increases with increasing fatigue load amplitude for the same number of fatigue cycles; for the specimens with fatigue damage, the interfacial stiffness of FRP-concrete decreases with the increase in the number of cyclic, and the rate of stiffness damage at the FRP-concrete interface accelerates with increasing fatigue load amplitude. For fatigue load magnitudes higher than 0.6, the slopes of fatigue bond-slip curves decrease with the increase in the number of cycles. When the fatigue load magnitude is lower than 0.4, the slope of the fatigue bond-slip curve increases with the number of cycles and is close to the slope of the monotonically loaded curve. Due to the difference in load class, the bond strength of HB-F-1 continues to decrease with the increase in fatigue times, decreasing by 26% after 100 fatigue cycles and decreasing to 7.33 MPa after 5000 fatigue cycles. The bond strength of the sample HB-F-2 first increased and then decreased with the increase in fatigue times. After 10,000 fatigue cycles, the bond strength decreased by 8%, and at 11,133,300 fatigue breaks, the bond strength of the sample HB-F-3 continued to increase with the increase in fatigue times. At 2 million fatigue load cycles, the bond strength increased to 7 MPa, far from reaching the peak strength. The empirical formulas for the fatigue life curve of HB-FRP-reinforced specimens under single steel fasteners are proposed.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Deformation characteristics, static and fatigue strengths of reinforced concrete beams strengthened with carbon fiber-reinforced plastic plate
    Inoue, Shoichi
    Nishibayashi, Shinzo
    Yoshino, Akira
    Omata, Fujio
    Transactions of the Japan Concrete Institute, 1996, 18 : 143 - 150
  • [22] PLASTIC SHRINKAGE CRACKING OF POLYPROPYLENE FIBER-REINFORCED CONCRETE
    SOROUSHIAN, P
    MIRZA, F
    ALHOZAIMY, A
    ACI MATERIALS JOURNAL, 1995, 92 (05) : 553 - 560
  • [23] Performance of plastic wastes in fiber-reinforced concrete beams
    Khalid, F. S.
    Irwan, J. M.
    Ibrahim, M. H. Wan
    Othman, N.
    Shahidan, S.
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 183 : 451 - 464
  • [24] Tests of Continuous Concrete Slabs Reinforced with Basalt Fiber-Reinforced Plastic Bars
    Kara, Ilker Fatih
    Koroglu, Mehmet Alpaslan
    Ashour, Ashraf F.
    ACI STRUCTURAL JOURNAL, 2017, 114 (05) : 1201 - 1213
  • [25] Rehabilitation of cracked and corroded reinforced concrete beams with fiber-reinforced plastic patches
    Wang, CY
    Shih, CC
    Hong, SC
    Hwang, WC
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2004, 8 (03) : 219 - 228
  • [26] Flexural fatigue analysis of steel fiber-reinforced concrete
    Singh, SP
    Kaushik, SK
    ACI MATERIALS JOURNAL, 2001, 98 (04) : 306 - 312
  • [27] Fatigue characteristics of high performance fiber-reinforced concrete
    Naaman, AE
    Hammoud, H
    CEMENT & CONCRETE COMPOSITES, 1998, 20 (05): : 353 - 363
  • [28] Fiber-Reinforced Polymers and Fiber-Reinforced Concrete in Civil Engineering
    Shi, Jianzhe
    BUILDINGS, 2023, 13 (07)
  • [29] Fatigue cracking resistance of fiber-reinforced asphalt concrete
    Lee, SJ
    Rust, JP
    Hamouda, H
    Kim, YR
    Borden, RH
    TEXTILE RESEARCH JOURNAL, 2005, 75 (02) : 123 - 128
  • [30] Laboratory Fatigue and Toughness Evaluation of Fiber-Reinforced Concrete
    Mulheron, Matthew
    Kevern, John T.
    Rupnow, Tyson D.
    TRANSPORTATION RESEARCH RECORD, 2015, (2508) : 39 - 47