Interface Fatigue Test of Hybrid-Bonded Fiber-Reinforced Plastic-Reinforced Concrete Specimen

被引:0
|
作者
Zhou, Kun [1 ]
Wei, Qian [2 ]
Wang, Jiabin [3 ]
Gao, Lei [2 ]
Dong, Chao [3 ]
Zhang, Zejun [3 ]
Fu, Kunhao [3 ]
Cheng, Ziqin [4 ]
机构
[1] Shandong Hispeed Construct Management Grp Co Ltd, Jinan 250014, Peoples R China
[2] Shandong Univ, Geotech & Struct Engn Res Ctr, Jinan 250061, Peoples R China
[3] Shandong Hispeed Yanpeng Highway Co Ltd, Weihai 265800, Peoples R China
[4] Shandong High Speed Grp Co Ltd, Innovat Res Inst, Jinan 250098, Peoples R China
关键词
FRP; fatigue property; interfaces property; bond-slip relationship; FRP; PREDICTION;
D O I
10.3390/buildings14103080
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This research produced five hybrid-bonded fiber-reinforced plastic (HB-FRP)-reinforced beam specimens, and different fatigue load amplitudes were used as parameter variables for the fatigue performance tests of the FRP-concrete interface. The results show that FRP sliding with the number of cycles can be roughly divided into fatigue initiation stage, fatigue development stage, and fatigue damage stage, and finally, because the load is too large and friction, pin, and bonding cannot provide a greater inhibition effect, FRP adhesive length is not enough to withstand the stripping load and failure. FRP slip increases with increasing fatigue load amplitude for the same number of fatigue cycles; for the specimens with fatigue damage, the interfacial stiffness of FRP-concrete decreases with the increase in the number of cyclic, and the rate of stiffness damage at the FRP-concrete interface accelerates with increasing fatigue load amplitude. For fatigue load magnitudes higher than 0.6, the slopes of fatigue bond-slip curves decrease with the increase in the number of cycles. When the fatigue load magnitude is lower than 0.4, the slope of the fatigue bond-slip curve increases with the number of cycles and is close to the slope of the monotonically loaded curve. Due to the difference in load class, the bond strength of HB-F-1 continues to decrease with the increase in fatigue times, decreasing by 26% after 100 fatigue cycles and decreasing to 7.33 MPa after 5000 fatigue cycles. The bond strength of the sample HB-F-2 first increased and then decreased with the increase in fatigue times. After 10,000 fatigue cycles, the bond strength decreased by 8%, and at 11,133,300 fatigue breaks, the bond strength of the sample HB-F-3 continued to increase with the increase in fatigue times. At 2 million fatigue load cycles, the bond strength increased to 7 MPa, far from reaching the peak strength. The empirical formulas for the fatigue life curve of HB-FRP-reinforced specimens under single steel fasteners are proposed.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Mode I fatigue of the carbon fiber-reinforced plastic—concrete interface bond
    T. Nicholas
    S. E. Chen
    D. Boyajian
    Experimental Techniques, 2012, 36 : 67 - 73
  • [2] Mode I Fatigue of the Carbon Fiber-Reinforced Plastic-Concrete Interface Bond
    Nicholas, T.
    Chen, S. -E.
    Boyajian, D.
    EXPERIMENTAL TECHNIQUES, 2012, 36 (04) : 67 - 73
  • [3] Ultimate Strength of Reinforced Concrete Beams Retrofitted with Hybrid Bonded Fiber-Reinforced Polymer
    Wu, Yu-Fei
    Yan, Jun-Hui
    Zhou, Ying-Wu
    Xiao, Yan
    ACI STRUCTURAL JOURNAL, 2010, 107 (04) : 451 - 460
  • [4] FIBER-REINFORCED PLASTIC GRID FOR REINFORCED-CONCRETE CONSTRUCTION
    SCHMECKPEPER, ER
    GOODSPEED, CH
    JOURNAL OF COMPOSITE MATERIALS, 1994, 28 (14) : 1288 - 1304
  • [5] BEHAVIOR OF CONCRETE SLABS REINFORCED WITH FIBER-REINFORCED PLASTIC GRID
    BANTHIA, N
    ALASALY, M
    MA, S
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 1995, 7 (04) : 252 - 257
  • [6] Behavior of concrete slabs reinforced with fiber-reinforced plastic grid
    Univ of British Columbia, Vancouver, Canada
    J Mater Civ Eng, 4 (252-257):
  • [7] Energy release in fiber-reinforced plastic reinforced concrete beams
    Orozco, AL
    Maji, AK
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2004, 8 (01) : 52 - 58
  • [8] Fiber-reinforced plastic rebars for concrete applications
    Chaallal, O
    Benmokrane, B
    COMPOSITES PART B-ENGINEERING, 1996, 27 (3-4) : 245 - 252
  • [9] Fatigue Performance Test and Life Calculation of Fiber-Reinforced Asphalt Concrete
    Meng, Fenglin
    Gao, Danying
    Chen, Faqi
    Huang, Chunshui
    ANNALES DE CHIMIE-SCIENCE DES MATERIAUX, 2020, 44 (02): : 133 - 139
  • [10] Fatigue behavior of fiber-reinforced concrete in compression
    Cachim, PB
    Figueiras, JA
    Pereira, PAA
    CEMENT & CONCRETE COMPOSITES, 2002, 24 (02): : 211 - 217