Deep learning based highly accurate transplanted bioengineered corneal equivalent thickness measurement using optical coherence tomography

被引:1
|
作者
Seong, Daewoon [1 ]
Lee, Euimin [1 ]
Kim, Yoonseok [1 ]
Yae, Che Gyem [2 ,3 ]
Choi, JeongMun [2 ,3 ]
Kim, Hong Kyun [2 ,3 ]
Jeon, Mansik [1 ]
Kim, Jeehyun [1 ]
机构
[1] Kyungpook Natl Univ, Coll IT Engn, Sch Elect & Elect Engn, Daegu, South Korea
[2] Kyungpook Natl Univ Hosp, Biomed Inst, Daegu, South Korea
[3] Kyungpook Natl Univ, Sch Med, Dept Ophthalmol, Daegu, South Korea
来源
NPJ DIGITAL MEDICINE | 2024年 / 7卷 / 01期
基金
新加坡国家研究基金会;
关键词
ULTRASONIC PACHYMETRY; CONFOCAL MICROSCOPY; REPRODUCIBILITY; SEGMENTATION; TOPOGRAPHY; SCAFFOLDS; GLAUCOMA; FEATURES; COLLAGEN;
D O I
10.1038/s41746-024-01305-3
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Corneal transplantation is the primary treatment for irreversible corneal diseases, but due to limited donor availability, bioengineered corneal equivalents are being developed as a solution, with biocompatibility, structural integrity, and physical function considered key factors. Since conventional evaluation methods may not fully capture the complex properties of the cornea, there is a need for advanced imaging and assessment techniques. In this study, we proposed a deep learning-based automatic segmentation method for transplanted bioengineered corneal equivalents using optical coherence tomography to achieve a highly accurate evaluation of graft integrity and biocompatibility. Our method provides quantitative individual thickness values, detailed maps, and volume measurements of the bioengineered corneal equivalents, and has been validated through 14 days of monitoring. Based on the results, it is expected to have high clinical utility as a quantitative assessment method for human keratoplasties, including automatic opacity area segmentation and implanted graft part extraction, beyond animal studies.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Optical coherence tomography enables accurate measurement of equine cartilage thickness for determination of speed of sound
    Puhakka, Pia H.
    te Moller, Nikae C. R.
    Tanska, Petri
    Saarakkala, Simo
    Tiitu, Virpi
    Korhonen, Rami K.
    Brommer, Harold
    Viren, Tuomas
    Jurvelin, Jukka S.
    Toyras, Juha
    ACTA ORTHOPAEDICA, 2016, 87 (04) : 418 - 424
  • [32] Changes in Corneal Thickness in Congenital Glaucoma, Using Anterior Segment Optical Coherence Tomography
    Lee, Chaeyeon
    Lee, Eun Jung
    Jang, Yoonkyung
    Han, Jong Chul
    Kee, Chang Won
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (08): : 692 - 699
  • [33] Deep Learning Based on Ensemble to Diagnose of Retinal Disease using Optical Coherence Tomography
    Pin, Kuntha
    Nam, Yunyoung
    Ha, Sangho
    Han, Jung Woo
    2021 INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE AND COMPUTATIONAL INTELLIGENCE (CSCI 2021), 2021, : 661 - 664
  • [34] Automated Monitoring for Optical Coherence Tomography-based Biosensing Using Deep Learning
    Kim, Heejong
    Yu, Chun-Nam
    Kennedy, William
    Eggleston, Michael
    Shah, Shreyas
    2020 IEEE PHOTONICS CONFERENCE (IPC), 2020,
  • [35] Microparticle-Based Biochemical Sensing Using Optical Coherence Tomography and Deep Learning
    Shah, Shreyas
    Yu, Chun-Nam
    Zheng, Mingde
    Kim, Heejong
    Eggleston, Michael S.
    ACS NANO, 2021, 15 (06) : 9764 - 9774
  • [36] Intraoperative Corneal Thickness Measurement by Optical Coherence Tomography in Keratoconic Patients Undergoing Corneal Collagen Cross-Linking
    Mazzotta, Cosimo
    Caragiuli, Stefano
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (06) : 1156 - 1162
  • [37] Measurement of the remaining dentin thickness using optical coherence tomography for crown preparation
    Fujita, Rie
    Komada, Wataru
    Nozaki, Kosuke
    Miura, Hiroyuki
    DENTAL MATERIALS JOURNAL, 2014, 33 (03) : 355 - 362
  • [38] Measurement of epithelial thickness within the oral cavity using optical coherence tomography
    Prestin, Sven
    Rothschild, Sacha I.
    Betz, Christian Stephan
    Kraft, Marcel
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2012, 34 (12): : 1777 - 1781
  • [39] Retinal thickness measurement in myopic eyes using optical coherence tomography.
    Hoh, ST
    Aung, T
    Seah, SKL
    Lim, WK
    Wu, HM
    Lee, L
    Chew, SJ
    Foster, PJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S297 - S297
  • [40] Measurement of Corneal and Limbal Epithelial Thickness by In Vivo Confocal Microscopy and Anterior Segment Optical Coherence Tomography
    Le, Qihua
    Chen, Yan
    Yang, Yujing
    Xu, JianJiang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)