Transient Voltage Unit Protection Based on Fault Information Fusion

被引:0
|
作者
Guo, Zhenwei [1 ]
Zhao, Ruiqiang [1 ]
Li, Haojie [1 ]
Jiang, Yongyan [1 ]
机构
[1] Guilin Univ Elect Sci & Technol, Sch Elect & Mech Engn, Guilin 541004, Peoples R China
来源
IEEE ACCESS | 2024年 / 12卷
基金
中国国家自然科学基金;
关键词
Protection; Voltage; Transient analysis; Signal processing algorithms; Resistance; Power system reliability; Feature extraction; Power transmission lines; Power system stability; Standards; Voltage transient protection; fault condition attributes; fault information fusion; synthetic fault characteristics; VMD-HT; TRAVELING-WAVE; BOUNDARY PROTECTION; SCHEME;
D O I
10.1109/ACCESS.2024.3513452
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Transient protection has the advantage of ultra-fast operation. However, traditional transient protection is susceptible to the influences of transitional resistance and the initial fault angle, resulting in issues with sensitivity and reliability under weak fault conditions. To address these issues, a new method of transient voltage protection is proposed by mining the equipment configuration information of the bus and line, as well as the frequency characteristics of the line boundary. To solve the problem that single-terminal transient line protection cannot distinguish between line fault and bus fault and the fault of adjacent line head end, a new fault feature is constructed by introducing a difference of instantaneous amplitude of the high-frequency signals between line voltage and bus voltage. To solve the problem that transient protection is susceptible to the influence of fault condition attributes, the fusion of fault characteristics with fault condition attributes results in synthetic fault characteristics, which contain fault attribute information. This approach overcame the adverse effects of fault attributes on transient protection and enhances protection reliability. Transient voltage high-frequency instantaneous amplitudes are obtained and integrated using the Variational Mode Decomposition Hilbert Transform (VMD-HT) to increase the stability of high-frequency fault signal detection. This algorithm solved the original problem of 42.2% cross-data, 41.6% false operations, and 8.9% refusal to operate. It protects both the full length of a transmission line and a busbar at the same time, with twice protection zone comparing with traditional protection. It is simpler, more reliable and more economical. Extensive ATP-Draw simulation experiments have validated the accuracy and reliability of the proposed algorithm.
引用
收藏
页码:184583 / 184591
页数:9
相关论文
共 50 条
  • [31] Fault diagnosis of high voltage circuit breaker based on multi-sensor information fusion with training weights
    Zhang, Jianzhong
    Wu, Yongbin
    Xu, Zheng
    Din, Zakiud
    Chen, Hao
    MEASUREMENT, 2022, 192
  • [32] A Transient Voltage-Based DC Fault Line Protection Scheme for MMC-Based DC Grid Embedding DC Breakers
    Xiang, Wang
    Yang, Saizhao
    Xu, Lie
    Zhang, Junjie
    Lin, Weixing
    Wen, Jinyu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (01) : 334 - 345
  • [33] Substation fault analysis system based on integration of fault records and protection information
    Xu, Yan
    Zhang, Xiaoming
    Wu, Zhuojuan
    He, Runming
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2011, 31 (01): : 118 - 121
  • [34] Power Grid Fault Diagnosis Based on Fault Information Coding and Fusion Method
    Zhao, Jinyong
    Wei, Yanfei
    Liu, Jie
    Wei, Shutong
    Wang, Zhongguo
    Ke, Yang
    Deng, Xiangli
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [35] Fault location method based on the periodicity of the transient voltage traveling wave
    Li, YL
    Zhang, Y
    Ma, ZY
    TENCON 2004 - 2004 IEEE REGION 10 CONFERENCE, VOLS A-D, PROCEEDINGS: ANALOG AND DIGITAL TECHNIQUES IN ELECTRICAL ENGINEERING, 2004, : C389 - C392
  • [36] MMC-HVDC line fault identification scheme based on single-ended transient voltage information entropy
    Shu, Hongchun
    Wang, Guangxue
    Tian, Xincui
    Ju, Xiayang
    An, Na
    Bo, Zhiqian
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 141
  • [37] Single-phase ground fault section localization method for small current system based on transient information fusion
    Li, Dahua
    Wang, Zongzheng
    Li, Dong
    Li, Xuan
    Tian, He
    Zhao, Yuexiang
    2024 6TH ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM, AEEES 2024, 2024, : 1101 - 1108
  • [38] Fault Location Estimation Based on Voltage Sag Information of PQMS
    Tao, Shun
    Zhao, Chenxue
    Luo, Chen
    Xiao, Xiangning
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,
  • [39] Mine ventilator fault diagnosis based on information fusion technique
    Shi Li-ping
    Han Li
    Wang Ke-wu
    Zhang Chuan-juan
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MINING SCIENCE & TECHNOLOGY (ICMST2009), 2009, 1 (01): : 1484 - 1488
  • [40] Research state and progress of fault diagnosis based on information fusion
    Lü, Feng
    Wang, Xiuqing
    Du, Hailian
    Xin, Tao
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2009, 37 (SUPPL. 1): : 217 - 221