Effect of Indenter Load on Vickers Microhardness and Indentation Depth of One Resin Composite

被引:0
|
作者
Price, Richard B. [1 ]
Sullivan, Braden [1 ]
机构
[1] Dalhousie Univ, Dept Dent Clin Sci, 5981 Univ Ave, Halifax, NS B3H 4R2, Canada
关键词
composite resin; polymerization; light-curing; hardness measurement; monomer conversion; indentation size effect; BULK-FILL RESIN; POLYMERIZATION SHRINKAGE; MECHANICAL-PROPERTIES; CURING CHARACTERISTICS; MARGINAL ADAPTATION; MONOMER CONVERSION; LIGHT; HARDNESS; CURE; SIZE;
D O I
10.3390/ma17246156
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The load and size of the indentation may affect the hardness value. This study investigated the effect of the indentation size on the microhardness of one resin-based composite (RBC). Metal molds 4 mm deep and 12 mm in diameter were filled with Tetric EvoCeram Bulk Fill (Ivoclar) and light-cured for 10 s using a broad-spectrum LED curing light. The Vickers microhardness and the degree of conversion (DC) at the top and bottom surfaces were measured 24 h later before and after polishing the RBC. The microhardness measurements were made using 50, 100, 300 and 1000-gf loads with the same 8 s dwell time. The DC was measured in the same region using mid FT-IR spectroscopy. Repeated measures analysis of variance tests were used to determine if the surface (top vs. bottom) or the indenter loads had a significant effect on the VH, or if polishing affected the VH and the DC (alpha = 0.05). It was found that the indenter load did not affect the Vickers hardness of the unpolished top surface (p = 0.759), the polished top surface (p = 0.374), or the polished bottom surface (p = 0.083) of the Tetric EvoCeram Bulk Fill. Increasing the indenter load did increase the VH of the unpolished surface at the bottom (p < 0.0001). Polishing increased the DC by 13.5% at the top and by 46.7% at the bottom surface.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] THE EFFECT OF THE GEOMETRICAL SHAPES OF PYRAMID INDENTORS ON THE ACCURACY OF MICROHARDNESS READINGS BASED ON MEASURING THE DEPTH OF THE INDENTATION
    SKVORTSOV, VN
    SOVIET ENGINEERING RESEARCH, 1985, 5 (01): : 25 - 27
  • [32] Finite element analysis on the effect of indenter diameter and load on the contact stresses during indentation of coated systems
    Pérez, EA
    Souza, RM
    ISMANAM 2003: METASTABLE, MECHANICALLY ALLOYED AND NANOCRYSTALLINE MATERIALS, 2004, 20-21 : 763 - 768
  • [33] Effect of transmittance through composite resin on cured depth
    Fujita, K
    Kohno, Y
    Ikemi, T
    Nishiyama, N
    Nemoto, K
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 2213 - 2213
  • [34] The effect of a translucent post on resin composite depth of cure
    Roberts, HW
    Leonard, DL
    Vandewalle, KS
    Cohen, ME
    Charlton, DG
    DENTAL MATERIALS, 2004, 20 (07) : 617 - 622
  • [35] The Effects of Intensity, Exposure Time, and Distance of Polymerization Light on Vickers Microhardness and Temperature Rise of Conventional Resin-Based Composite
    Duratbegovic, Damir
    Pervan, Nedim
    Jakupovic, Selma
    Kobaslija, Sedin
    POLYMERS, 2024, 16 (22)
  • [36] Analysis of indentation size effect (ISE) behavior in low-load Vickers microhardness testing of (Sm123)1−x(Nd123)x superconductor system
    S. Celik
    O. Ozturk
    E. Coşkun
    M. Sarıhan
    E. Asikuzun
    K. Ozturk
    C. Terzioglu
    Journal of Materials Science: Materials in Electronics, 2013, 24 : 2218 - 2227
  • [37] Evaluation of the microhardness a commercial brand of one composite resin submitted to three types of photocuring equipments
    Machado, CT
    Neto, ST
    Cruz, CAS
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B206 - B206
  • [38] Indentation load effect on young's modulus and hardness of porous sialon ceramic by depth sensing indentation tests
    Sahin, Osman
    CHINESE PHYSICS LETTERS, 2007, 24 (11) : 3206 - 3209
  • [39] Argon ion laser curing depth effect on a composite resin
    Turbino, Miriam Lacalle
    Belan, Luis Carlos
    Soprano, Valeria
    Rode, Katia Martis
    Lloret, Patricia Ramos
    Youssef, Michel Nicolau
    LASERS IN MEDICAL SCIENCE, 2011, 26 (04) : 421 - 425
  • [40] Argon ion laser curing depth effect on a composite resin
    Míriam Lacalle Turbino
    Luis Carlos Belan
    Valéria Soprano
    Kátia Martis Rode
    Patrícia Ramos Lloret
    Michel Nicolau Youssef
    Lasers in Medical Science, 2011, 26 : 421 - 425