AUTOMATIC READING DEVICE FOR AN ICE CALORIMETER.

被引:0
|
作者
Zakurenko, O.E. [1 ]
Kuz'michev, V.M. [1 ]
机构
[1] Kharkov State Univ, Kharkov, USSR, Kharkov State Univ, Kharkov, USSR
来源
Instruments and experimental techniques New York | 1984年 / 27卷 / 5 pt 2期
关键词
ICE - Thermal Expansion - INSTRUMENTS - Automatic Operation;
D O I
暂无
中图分类号
学科分类号
摘要
The design of an automatic reading device for an ice calorimeter, the operation of which is based on the weak dependence of the constant of the ice calorimeter on the excess, in relation to atmospheric pressure in its calorimetric vessel, is described. The measurement error at the upper limit of 400 J is approximately 9. 5%. When the magnitude of the automatic shift of the plunger of the dosing apparatus was read with the aid of a reading microscope and a IZA-2 scale, the constant of the instrument was 46. 28 J/mm, while the measurement error at the upper limit of 3600 J was approximately 1%.
引用
收藏
页码:1292 / 1293
相关论文
共 50 条
  • [21] CUSB-II BGO CALORIMETER.
    Tuts, P.Michael
    Nuclear instruments and methods in physics research, 1987, A265 (1-2): : 243 - 251
  • [22] TWIN HIGH-TEMPERATURE CALORIMETER.
    Kamimoto, Masayuki
    Hagiwara, Seiichi
    Bulletin of the Electrotechnical Laboratory, Tokyo, 1982, 46 (10): : 30 - 35
  • [23] CDF FORWARD/BACKWARD HADRON CALORIMETER.
    Cihangir, S.
    Marchetto, F.
    McIntyre, P.
    Meyer, T.
    Webb, R.
    Nuclear instruments and methods in physics research, 1988, A267 (2-3): : 249 - 256
  • [24] Precise cooling of the ECAL-CMS calorimeter.
    Baillon, P
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2000, : 274 - 283
  • [25] PERFORMANCE AND RADIATION DAMAGE OF A LEAD/SCINTILLATOR CALORIMETER.
    Saitoh, Hitoshi
    Murashita, Masayuki
    Tobimatsu, Keijiro
    Chiba, Masami
    Hirose, Tachishige
    Takasaki, Fumihiko
    1600, (25):
  • [26] Measuring of specific warmths with a new liquid calorimeter.
    Schottky, H
    PHYSIKALISCHE ZEITSCHRIFT, 1909, 10 : 634 - 639
  • [27] NEW FORMULAE FOR ENERGY RESOLUTION OF SAMPLING CALORIMETER.
    Suzuki, Satoshi
    Masuda, Kimiaki
    Doke, Tadayoshi
    1600, (24):
  • [28] CALIBRATION SYSTEMS FOR THE CDF CENTRAL ELECTROMAGNETIC CALORIMETER.
    Hahn, S.R.
    Miller, M.
    Connor, D.
    Bauer, D.
    Cooper, J.W.
    Pierce, R.
    Mueller, W.
    Van Berg, R.
    Williams, H.H.
    Li, W.
    Nodulman, L.
    Proudfoot, J.
    Rezmer, R.
    Underwood, D.
    Wagner, R.G.
    Nuclear instruments and methods in physics research, 1988, A267 (2-3): : 351 - 366
  • [29] CALIBRATION OF THE CHARM FINE-GRAINED CALORIMETER.
    Dorenbosch, J.
    Udo, F.
    Allaby, J.V.
    Amaldi, U.
    Barbiellini, G.
    Bergsma, F.
    Capone, A.
    Flegel, W.
    Lanceri, L.
    Metcalf, M.
    Nieuwenhuis, C.
    Panman, J.
    Santoni, C.
    Winter, K.
    Abt, I.
    Nuclear instruments and methods in physics research, 1987, A253 (02): : 203 - 221
  • [30] COMBINED PHOTON-HADRON HODOSCOPE CALORIMETER.
    Binon, F.G.
    Bricman, C.
    Duteil, P.
    Gouanere, M.
    Kachanov, V.A.
    Kakauridze, D.B.
    Khaustov, G.V.
    Lagnaux, J.P.
    Mouthuy, Th.
    Peigneux, J.P.
    Possoz, A.
    Prokoshkin, Yu.D.
    Rykalin, V.I.
    Shagin, P.M.
    Sillou, D.
    Nuclear instruments and methods in physics research, 1988, A269 (01): : 101 - 108