IMPROVING THE ACCURACY OF AMPLITUDE MEASUREMENTS BY SAMPLING OSCILLOSCOPES.

被引:0
|
作者
Levitas, B.N.
Roizentok, V.S.
Rossoskii, Ya.M.
Shapiro, E.I.
机构
关键词
COMPUTERS; MICROCOMPUTER; -; OSCILLOSCOPES; CATHODE RAY;
D O I
暂无
中图分类号
学科分类号
摘要
The authors discuss problems associated with the improvement of the accuracy of measurement of parameters of pulse and harmonic signals by the histogram method and with the measurement of high-frequency (HF) signal amplitude with the aid of a synchronizer. The following conclusions can be drawn from this study. The error in measuring signal parameters with the aid of a sampling oscilloscope depends on the noise in horizontal and vertical deflection channels. Application of the histogram method gives simple algorithms for measuring certain parameters of pulse and sinusoidal signals and makes it possible to eliminate the effect of the horizontal channel noise on the results of measurement. Vertical deflection channel noise is a source of a systematic error in the measurement of sinusoidal signal amplitude by the histogram method. This error can be calculated and eliminated as proved by experimental measurements carried out with the S9-9 precision sampling oscilloscope.
引用
收藏
页码:127 / 131
相关论文
共 50 条
  • [41] FEEDTHROUGH INDUCED DISTROTIONS IN SAMPLING OSCILLOSCOPES AND THEIR COMPENSATION
    BOSSHARD, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1971, 42 (01): : 85 - &
  • [42] Measurements of transient phenomena with digital oscilloscopes
    Moschitta, Antonio
    Stefani, Fabrizio
    Petri, Dario
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (06) : 2486 - 2491
  • [43] Measurements of transient phenomena with digital oscilloscopes
    Moschitta, A
    Stefani, F
    Petri, D
    IMTC/O3: PROCEEDINGS OF THE 20TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1 AND 2, 2003, : 1345 - 1349
  • [44] RECENT DEVELOPMENTS IN THE CALIBRATION OF FAST SAMPLING OSCILLOSCOPES
    HENDERSON, D
    RODDIE, AG
    SMITH, AJA
    IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1992, 139 (05): : 254 - 260
  • [45] STUDY OF PICOSECOND PULSES WITH SAMPLING OSCILLOSCOPES AND DEVICES
    RYABININ, YA
    KLEMENSOV, VA
    BALAEV, AP
    SHCHERBAKOV, VV
    TSAL, VV
    MEASUREMENT TECHNIQUES USSR, 1984, 27 (01): : 72 - 76
  • [46] Improving Consistency and Accuracy of Neonatal Amplitude-Integrated Electroencephalography
    Tsoi, Kathleen
    Yam, Karen K. M.
    Cheung, Hon M.
    Ma, Terence P. Y.
    So, King W.
    Fung, Eva L. W.
    Lam, Hugh S.
    AMERICAN JOURNAL OF PERINATOLOGY, 2024, 41 (03) : 330 - 336
  • [47] SAMPLING OSCILLOSCOPES FOR ECONOMICAL HIGH-FREQUENCY MEASUREMENT
    WALTERS, E
    MICROWAVE JOURNAL, 1987, 30 (01) : 155 - &
  • [48] IMPROVING THE ACCURACY OF ELECTRIC-POWER MEASUREMENTS
    ANTONEVICH, VF
    ZABELLO, EP
    MEASUREMENT TECHNIQUES USSR, 1989, 32 (07): : 703 - 705
  • [49] IMPROVING ACCURACY OF PHASE-DIFFERENCE MEASUREMENTS
    DATSKO, RV
    MESTECHKIN, VK
    MEASUREMENT TECHNIQUES, 1973, 16 (05) : 717 - 719
  • [50] IMPROVING THE SIGNAL RECOVERY ACCURACY IN DISCRETE MEASUREMENTS
    MATVEEV, AA
    MATVEEV, AA
    MEASUREMENT TECHNIQUES USSR, 1990, 33 (09): : 849 - 854