PERFORMANCE OF A SEGMENTED Ge/BGO DETECTOR AS AN ESCAPE SUPPRESSED AND PAIR SPECTROMETER.

被引:0
|
作者
Emling, H. [1 ]
Azgui, F. [1 ]
Daether, M. [1 ]
Doebereiner, S. [1 ]
Grein, H. [1 ]
Michel, C. [1 ]
Wollersheim, H.J. [1 ]
机构
[1] Gesellschaft fuer, Schwerionenforschung, Darmstadt,, West Ger, Gesellschaft fuer Schwerionenforschung, Darmstadt, West Ger
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
18
引用
收藏
页码:320 / 324
相关论文
共 9 条
  • [1] PERFORMANCE OF A SEGMENTED GE/BGO DETECTOR AS AN ESCAPE SUPPRESSED AND PAIR SPECTROMETER
    EMLING, H
    AZGUI, F
    DATHER, M
    DOEBEREINER, S
    GREIN, H
    MICHEL, C
    WOLLERSHEIM, HJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 249 (2-3): : 320 - 324
  • [2] PERFORMANCE OF A SPECIAL GEOMETRY BISMUTH GERMANATE ESCAPE SUPPRESSED SPECTROMETER.
    Simpson, J.
    Bates, M.
    Brookes, C.
    Nolan, P.J.
    Nuclear instruments and methods in physics research, 1988, A269 (01): : 209 - 212
  • [3] A PAIR AND ESCAPE-SUPPRESSED SPECTROMETER USING GE(LI) AND NAI(TL) DETECTORS DESIGNED FOR ACCELERATOR EXPERIMENTS
    ALEXANDER, TK
    BROUDE, C
    HAUSSER, O
    SHARPEYS.JF
    NUCLEAR INSTRUMENTS & METHODS, 1968, 65 (02): : 169 - +
  • [4] MEASUREMENT OF REACTION THRESHOLDS USING AN ESCAPE SUPPRESSED GE(LI) SPECTROMETER
    SHARPEYSCHAFER, JF
    ALNASER, AM
    BEHBEHANI, AH
    GREEN, LL
    JAMES, AN
    LISTER, CJ
    NOLAN, PJ
    NUCLEAR INSTRUMENTS & METHODS, 1976, 135 (03): : 583 - 585
  • [5] THE PERFORMANCE OF A BISMUTH-GERMANATE ESCAPE SUPPRESSED SPECTROMETER
    NOLAN, PJ
    GIFFORD, DW
    TWIN, PJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 236 (01): : 95 - 99
  • [6] THE PERFORMANCE OF A SPECIAL GEOMETRY BISMUTH-GERMANATE ESCAPE SUPPRESSED SPECTROMETER
    SIMPSON, J
    BATES, M
    BROOKES, C
    NOLAN, PJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 269 (01): : 209 - 212
  • [7] Performance of a Segmented Planar Ge detector and its Coupling with the clover HPGe Detector
    Sethi, J.
    Palit, R.
    Saha, S.
    Naidu, B. S.
    INTERNATIONAL CONFERENCE ON RECENT TRENDS IN NUCLEAR PHYSICS-2012 (ICRTNP-2012), 2013, 1524 : 287 - 291
  • [8] Performance of a Ge-BGO Compton-suppression spectrometer and its application to photon activation analysis
    Fukuda, K
    Ohkuma, J
    Asano, T
    Satoh, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 114 (3-4): : 379 - 386
  • [9] IMPROVEMENT OF THE PERFORMANCE OF A COMPTON-SUPPRESSION SPECTROMETER BY MINIMIZING THE DEAD LAYER OF THE CENTRAL GE DETECTOR
    AARTS, HJM
    ENGELBERTINK, GAP
    VANDERPOEL, CJ
    SCHERPENZEEL, DEC
    ARCISZEWSKI, HFR
    NUCLEAR INSTRUMENTS & METHODS, 1980, 172 (03): : 439 - 446