A PAIR AND ESCAPE-SUPPRESSED SPECTROMETER USING GE(LI) AND NAI(TL) DETECTORS DESIGNED FOR ACCELERATOR EXPERIMENTS

被引:20
|
作者
ALEXANDER, TK
BROUDE, C
HAUSSER, O
SHARPEYS.JF
机构
来源
NUCLEAR INSTRUMENTS & METHODS | 1968年 / 65卷 / 02期
关键词
D O I
10.1016/0029-554X(68)90558-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
引用
收藏
页码:169 / +
页数:1
相关论文
共 19 条
  • [1] MEASUREMENT OF REACTION THRESHOLDS USING AN ESCAPE SUPPRESSED GE(LI) SPECTROMETER
    SHARPEYSCHAFER, JF
    ALNASER, AM
    BEHBEHANI, AH
    GREEN, LL
    JAMES, AN
    LISTER, CJ
    NOLAN, PJ
    NUCLEAR INSTRUMENTS & METHODS, 1976, 135 (03): : 583 - 585
  • [2] CHARACTERISTICS OF A GE (LI)-NAI (TL) SPECTROMETER IN 3 MODES OF OPERATION
    STOUT, K
    MENEFEE, J
    APPLIED SPECTROSCOPY, 1968, 22 (04) : 370 - &
  • [3] IN-BEAM GE(LI)-NAI(TL) COMPTON SUPPRESSION SPECTROMETER
    BEETZ, R
    POSTHUMUS, WL
    DEBOER, FWN
    MAARLEVELD, JL
    VANDERSCHAAF, A
    KONIJN, J
    NUCLEAR INSTRUMENTS & METHODS, 1977, 145 (02): : 353 - 357
  • [4] CALCULATION OF ESCAPE PEAK FOR GE-LI AND NAI RADIATION DETECTORS
    FIORATTI, MP
    PIERMATTEI, SR
    NUCLEAR INSTRUMENTS & METHODS, 1971, 96 (04): : 605 - +
  • [5] TOTAL EFFICIENCY CALCULATION OF NAI(TL) OR GE-LI DETECTORS
    CESANA, A
    TERRANI, M
    ENERGIA NUCLEARE, 1978, 25 (03): : 155 - 157
  • [6] PERFORMANCE OF A SEGMENTED GE/BGO DETECTOR AS AN ESCAPE SUPPRESSED AND PAIR SPECTROMETER
    EMLING, H
    AZGUI, F
    DATHER, M
    DOEBEREINER, S
    GREIN, H
    MICHEL, C
    WOLLERSHEIM, HJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 249 (2-3): : 320 - 324
  • [7] RELATIVE SENSITIVITY AND ACCURACY OF NAI(TL) AND GE(LI) DETECTORS FOR MINOR COMPONENTS
    LUCAS, HF
    EDGINGTO.DN
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1973, 15 (02): : 467 - 472
  • [8] PERFORMANCE OF A SEGMENTED Ge/BGO DETECTOR AS AN ESCAPE SUPPRESSED AND PAIR SPECTROMETER.
    Emling, H.
    Azgui, F.
    Daether, M.
    Doebereiner, S.
    Grein, H.
    Michel, C.
    Wollersheim, H.J.
    Nuclear instruments and methods in physics research, 1986, A249 (2-3): : 320 - 324
  • [9] A GE(LI) GAMMA SPECTROMETER EMPLOYING AN ANTI-COMPTON MANTLE OF NAI(TL)
    KANTELE, J
    SUOMINEN, P
    NUCLEAR INSTRUMENTS & METHODS, 1966, 41 (01): : 41 - &
  • [10] 4PI BETA-GAMMA-COINCIDENCE SPECTROMETER USING SI(LI) AND NAI(TL) DETECTORS
    GILS, HJ
    WIESNER, W
    LOHKEN, R
    FLOTHMAN.D
    NUCLEAR INSTRUMENTS & METHODS, 1972, 105 (02): : 179 - &