Optimization of PIXE analysis for Cu and other trace elements in cerebrospinal fluid to improve the detection limits

被引:0
|
作者
Univ of Helsinki, Helsinki, Finland [1 ]
机构
关键词
Body fluids - Copper - Diseases - Electric conductivity - Neurology - Protons - Thermal conductivity - Trace elements - Ultrafiltration;
D O I
暂无
中图分类号
学科分类号
摘要
An external beam PIXE system was optimized for the determination of the extremely low trace element content of normal cerebrospinal fluid. In order to improve the detection limits of the elements of interest, the ultrafiltrated cerebrospinal fluid samples were deposited onto ultrathin Formvar foils and measured in a helium atmosphere. Since the main emphasis was on copper, the absorber used in the measurements was optimized to give a favourable peak/background ratio for this element. The resulting detection limits for Fe, Cu, Zn and Br were (6.3 ± 2.9), (4.1 ± 1.4), (8.5 ± 2.6) and (18.1 ± 1.1) ppb, respectively. This allowed sufficiently precise determination of the low elemental concentrations in 50 μl of human cerebrospinal fluid.
引用
下载
收藏
页码:320 / 324
相关论文
共 50 条
  • [21] Distribution of trace elements in bean sprouts determined by PIXE analysis
    Yukawa, M
    Kimura, A
    Watanabe, Y
    Sakurai, S
    TRACE ELEMENTS IN MAN AND ANIMALS - 9, 1997, : 265 - 266
  • [22] PIXE analysis of trace elements in northern fur seal teeth
    Arai, N
    Mitani, Y
    Sakamoto, W
    Yoshida, K
    Mokuno, Y
    Baba, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1999, 150 (1-4): : 267 - 271
  • [23] PIXE analysis of trace elements in northern fur seal teeth
    Arai, Nobuaki
    Mitani, Yoko
    Sakamoto, Wataru
    Yoshida, Koji
    Mokuno, Yoshiyuki
    Baba, Norihisa
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1999, 150 (1-4): : 267 - 271
  • [24] TRACE-ELEMENTS IN THE CEREBROSPINAL-FLUID IN NEUROLOGICAL DISEASES
    KJELLIN, KG
    CLINICAL TOXICOLOGY, 1981, 18 (11): : 1237 - 1245
  • [25] LIMITS OF DETECTION AND QUANTITATION IN PIXE ANALYSIS OF THICK TARGETS
    TEESDALE, WJ
    MAXWELL, JA
    PERUJO, A
    CAMPBELL, JL
    VANDERZWAN, L
    JACKMAN, TE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1988, 35 (01): : 57 - 66
  • [26] MINIMUM DETECTION LIMITS IN PIXE ANALYSIS OF THICK TARGETS
    CAMPBELL, JL
    PERUJO, A
    TEESDALE, WJ
    COOKSON, JA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1988, 30 (03): : 317 - 323
  • [27] Limits of detection and quantitation in PIXE analysis of thick targets
    Teesdale, W.J.
    Maxwell, J.A.
    Perujo, A.
    Campbell, J.L.
    Van Der Zwan, L.
    Jackman, T.E.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1988, B35 (01) : 57 - 66
  • [28] PIXE ANALYSIS OF WATER WITH DETECTION LIMITS IN THE PPB RANGE
    RICKEY, FA
    SIMMS, PC
    MUELLER, KA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (01) : 1347 - 1351
  • [29] LIMITS OF DETECTION FOR PIXE ANALYSIS USING PROTON MICROBEAM
    JAKSIC, M
    BOGDANOVIC, I
    FAZINIC, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 104 (1-4): : 152 - 156
  • [30] β-TRACE PROTEIN AS A MARKER FOR DETECTION CEREBROSPINAL FLUID LEAKAGE
    Stosic, G.
    Obradovic, I.
    Vujotic, L. J.
    Bogosavljevic, V.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S628 - S628