Cooling tower corrosion

被引:0
|
作者
Benner, Richard L. [1 ]
机构
[1] Benner Co, United States
关键词
Engineering - Materials - Corrosion Protection;
D O I
暂无
中图分类号
学科分类号
摘要
It is preferable that cooling towers not be installed in highly corrosive atmospheres. Once they are, it becomes expensive to move the towers. The next best solution is to take measures to protect the towers from further corrosion. This means the use of special epoxy-based paints on the exterior and/or a two-part polymer coating. Cooling tower life can be prolonged, and even extended, many years by reviewing the following steps: investigate the areas for the cause of corrosions; take steps to eliminate or minimize the culprit; investigate the use of coatings for the interior, and use a qualified person to apply the coatings, (usually the metal has to be ground down to a white metal finish before applying the coating); review any new cooling tower locations for possible elements that could create corrosive conditions for the tower.
引用
收藏
相关论文
共 50 条
  • [1] COOLING-TOWER CORROSION
    BENNER, RL
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1989, 31 (08): : 20 - &
  • [2] Corrosion control in cooling tower systems
    Hey, Gary W.
    Hollingshad, William R.
    ASHRAE Journal, 1988, 30 (08) : 33 - 36
  • [3] CORROSION CONTROL IN COOLING-TOWER SYSTEMS
    HEY, GW
    HOLLINGSHAD, WR
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1988, 30 (08): : 33 - 36
  • [4] Cooling tower designed to reduce maintenance and resist corrosion
    不详
    CORROSION PREVENTION & CONTROL, 1999, 46 (02): : 25 - +
  • [5] CORROSION AND BIOFOULING CONTROL IN A COOLING-TOWER SYSTEM
    COLTURI, TF
    KOZELSKI, KJ
    MATERIALS PERFORMANCE, 1984, 23 (08) : 43 - 47
  • [6] NEW AUTOMATIC SYSTEM OPTIMIZES COOLING TOWER CORROSION CONTROL
    FEITLER, H
    TOWNSEND, CR
    MATERIALS PROTECTION, 1969, 8 (03): : 19 - &
  • [7] The corrosion behaviour of galvanized steel in cooling tower water containing a biocide and a corrosion inhibitor
    Minnos, Bihter
    Ilhan-Sungur, Esra
    Cotuk, Aysin
    Gungor, Nihal Dogruoz
    Cansever, Nurhan
    BIOFOULING, 2013, 29 (03) : 223 - 235
  • [8] Cavitation-corrosion failure analysis in a cooling tower centrifugal pump
    Rosas, GN
    Valdez, SB
    Schorr, WM
    Leon, VJ
    CORROSION REVIEWS, 2004, 22 (03) : 249 - 265
  • [9] The Synergy Between Corrosion and Fatigue: Failure Analysis of an Aerator and a Cooling Tower
    da Rocha Magalhaes, Luciano
    da Silva Alvarenga, Rodrigo Freitas
    Resende, Flavio Augusto Coelho
    da Silva, Leonardo Rosa Ribeiro
    Bose Filho, Waldek Wladimir
    Franco, Sinesio Domingues
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2023, 23 (04) : 1803 - 1819
  • [10] Winning the Cooling Tower Trifecta: Controlling Corrosion, Scale, and Microbiological Fouling
    Daniels, David
    POWER, 2015, 159 (09) : 42 - 45