Analysis of rates of multiple enzymes in cell lysates by electrospray ionization mass spectrometry

被引:0
|
作者
Gerber, Scott A.
Scott, C. Ronald
Turecek, Frantisek
Gelb, Michael H.
机构
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [41] Analysis of hydrophobic proteins and peptides by electrospray ionization mass spectrometry
    Schaller, J
    Pellascio, BC
    Schlunegger, UP
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1997, 11 (04) : 418 - 426
  • [42] Targeted metabolomic analysis of Escherichia coli by desorption electrospray ionization and extractive electrospray ionization mass spectrometry
    Jackson, Ayanna U.
    Werner, Sean R.
    Talaty, Narl
    Song, Yishu
    Campbell, Karinna
    Cooks, R. Graham
    Morgan, John A.
    ANALYTICAL BIOCHEMISTRY, 2008, 375 (02) : 272 - 281
  • [43] Turnover rates in microorganisms by laser ablation electrospray ionization mass spectrometry and pulse-chase analysis
    Stopka, Sylwia A.
    Mansour, Tarek R.
    Shrestha, Bindesh
    Marechal, Eric
    Falconet, Denis
    Vertes, Akos
    ANALYTICA CHIMICA ACTA, 2016, 902 : 1 - 7
  • [44] Ion suppression effect in desorption electrospray ionization and electrospray ionization mass spectrometry
    Wang, Zheng
    Zhu, Haijing
    Huang, Guangming
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (23) : 1957 - 1962
  • [45] General assay for enzymes in the heptose biosynthesis pathways using electrospray ionization mass spectrometry
    Jimin Park
    Daeun Lee
    Eun Kyoung Seo
    Jae-Sang Ryu
    Dong Hae Shin
    Applied Microbiology and Biotechnology, 2017, 101 : 4521 - 4532
  • [46] General assay for enzymes in the heptose biosynthesis pathways using electrospray ionization mass spectrometry
    Park, Jimin
    Lee, Daeun
    Seo, Eun Kyoung
    Ryu, Jae-Sang
    Shin, Dong Hae
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2017, 101 (11) : 4521 - 4532
  • [47] Determination of micelle mass by electrospray ionization mass spectrometry
    Nohara, D
    Kajiura, T
    Takeda, K
    JOURNAL OF MASS SPECTROMETRY, 2005, 40 (04): : 489 - 493
  • [48] Dynamic mass spectrometry probe for electrospray ionization mass spectrometry monitoring of bioreactors for therapeutic cell manufacturing
    Chilmonczyk, Mason A.
    Kottke, Peter A.
    Stevens, Hazel Y.
    Guldberg, Robert E.
    Fedorov, Andrei G.
    BIOTECHNOLOGY AND BIOENGINEERING, 2019, 116 (01) : 121 - 131
  • [49] Multiple sprayer system for high-throughput electrospray ionization mass spectrometry
    Schneider, BB
    Douglas, DJ
    Chen, DDY
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (20) : 1982 - 1990
  • [50] ELECTROSPRAY IONIZATION MASS-SPECTROMETRY OF BIOMOLECULES
    JARDINE, I
    NATURE, 1990, 345 (6277) : 747 - 748