摘要
Hygrothermal performance of a new light-gauge steel framed building envelope system has been analyzed using 3-D thermal simulations, 2-D combined heat, air and moisture transfer simulations, laboratory testing in a calibrated and guarded hot box (ISO 8990), weather resistance tests for full-sized structures, corrosion tests and field measurements at experimental buildings in Ylojarvi, Central Finland. The results show that a modern steel wall structure based on perforated steel profiles performs satisfactorily in the cold climate of Finland. The perforations reduce heat loss along the web of the profile significantly. The field measurements show that no condensation has occurred in the frame system. Temperature measurements and infrared surveys in demonstration buildings show that surface temperatures are sufficiently high to prevent surface condensation or even increased humidity on the surface. According to the calculations, there are no severe corrosion risks in the steel frames in the Finnish climate. The climate, however, has an important effect on the performance, and the structures should be designed with regard to climatic conditions.
引用
收藏
页码:3 / 26
相关论文
共 50 条
  • [41] ECONOMICS OF LOW-RISE STEEL-FRAMED STRUCTURES
    RUDDY, JL
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1983, 20 (03): : 107 - 118
  • [42] Hygrothermal performance of timber-framed walls in Turkey - Long-term monitoring
    Kilicaslan, Aysegul Eksi
    Kus, Hulyas
    JOURNAL OF BUILDING ENGINEERING, 2024, 94
  • [43] The Relevance of Surface Resistances on the Conductive Thermal Resistance of Lightweight Steel-Framed Walls: A Numerical Simulation Study
    Santos, Paulo
    Abrantes, David
    Lopes, Paulo
    Moga, Ligia
    APPLIED SCIENCES-BASEL, 2024, 14 (09):
  • [44] Hygrothermal performance analysis of traditional timber framed houses' exterior walls: Safranbolu & Zeyrek
    Alkan, Seda Nur
    Yazicioglu, Fatih
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2024, 39 (02): : 1209 - 1222
  • [45] Hygrothermal performance optimization of lightweight steel-framed wall assemblies in hot-humid regions using orthogonal experimental design and a validated simulation model
    Zhan, Qiaosheng
    Xiao, Yiqiang
    Zhang, Lei
    Lin, Zhenghao
    Zou, Yukai
    Liao, Wei
    BUILDING AND ENVIRONMENT, 2023, 236
  • [46] Experimental Study on Fire Performance of Polymer Foam Cavity Insulated Light Steel Framed Walls
    Ščapec, Tomislav
    Skejić, Davor
    Rukavina, Marija Jelčić
    ce/papers, 2023, 6 (3-4) : 2114 - 2119
  • [47] IN-SITU TESTS TO EVALUATE THE STRUCTURAL PERFORMANCE OF A LARGE, IMPORTED STEEL-FRAMED GREENHOUSE
    Fuke, Yuta
    Okazaki, Taichiro
    Matsui, Ryota
    AIJ Journal of Technology and Design, 2022, 28 (70): : 1236 - 1241
  • [48] STEEL-FRAMED PARKING STRUCTURES - TIPS TO MAXIMIZE THEIR EFFICIENCY
    不详
    PUBLIC WORKS, 1984, 115 (03): : 78 - 79
  • [49] STEEL-FRAMED PARKING STRUCTURES - A GROWING TREND.
    Anon
    Construction Specifier, 1984, 37 (05): : 72 - 74
  • [50] Performance-Based Evaluation of Large Steel-Framed Structures in the Overall Fire Process
    Zhu, Guoqing
    Zhang, Guowei
    Yuan, Guanglin
    Li, Qingtao
    JOURNAL OF APPLIED MATHEMATICS, 2014,