Testing sterile air filter integrity

被引:0
|
作者
Sartorius Ltd, Longmead Business Centre, Blenheim Road, Epsom, Surrey KT19 9QN, United Kingdom [1 ]
机构
来源
Filtration and Separation | 2000年 / 37卷 / 02期
关键词
Bubbles (in fluids) - Diffusion in solids - Equipment testing - Filtration - Hydrophobicity - Polymeric membranes - Steam - Sterilization (cleaning) - Thermodynamic stability;
D O I
10.1016/S0015-1882(00)88319-6
中图分类号
学科分类号
摘要
Sterile air filter integrity is vital in aseptic processes and increasing regulatory demands are driving standards ever higher. Air filters in cartridge form must be mechanically and thermally stable to provide high performance over an operating lifetime that can be as long as two years. Since cartridges must withstand regular steam sterilization, wet gas flows and environments, it is important that the filter membrane is highly hydrophobic, and a cartridge design optimized for sterile air filtration and venting will provide sustained high performance with a concomitant reduction in consumable costs and energy consumption. The relevant test procedures such as the innovative water intrusion, bubble point and diffusion/pressure hold tests are reviewed.
引用
收藏
页码:24 / 25
相关论文
共 50 条
  • [41] Filter clogging issues in sterile filtration
    Sharma, Ashutosh
    Anderson, Sean
    Rathore, Anurag S.
    BIOPHARM INTERNATIONAL, 2008, 21 (04) : 53 - 57
  • [42] STERILE AIR FOR INDUSTRIAL FERMENTATIONS
    STARK, WH
    POHLER, GM
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1950, 42 (09): : 1789 - 1792
  • [44] PROCESSING WITH STERILE AIR FILTERS
    ROAST, CR
    DAIRY INDUSTRIES INTERNATIONAL, 1986, 51 (07) : 28 - 29
  • [45] STERILE AIR IN INTRAOCULAR SURGERY
    DEBARROS, EC
    AMA ARCHIVES OF OPHTHALMOLOGY, 1954, 52 (03): : 490 - 490
  • [46] STERILE AIR IN INTRAOCULAR SURGERY
    CRAIG, PC
    AMA ARCHIVES OF OPHTHALMOLOGY, 1954, 51 (05): : 701 - 701
  • [47] Testing the Integrity of a Roux-en-Y Hepaticojejunostomy: The Air Insufflation Test
    Saxena, Rajan
    Reddy, Venkata Vishwanath
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2019, 229 (02) : E1 - E3
  • [48] The standard method for testing air filter used in general ventilation in China
    Tu, GB
    Jia, JX
    Xing, YJ
    Yang, J
    INSTITUTE OF ENVIRONMENTAL SCIENCES AND TECHNOLOGY, 1998 PROCEEDINGS - CONTAMINATION CONTROL, 1998, : 435 - 438
  • [49] Aerosol challenge integrity testing of compressed air and gas sterilisation filters - A practical approach
    Binns, D
    7TH WORLD FILTRATION CONGRESS, PROCEEDINGS, VOLS I AND II, 1996, : 718 - 727
  • [50] Testing the structural integrity of the Air Force's emergency passenger oxygen system at altitude
    Garner, Robert P.
    Murphy, Richard E.
    Donnelley, Steve S.
    Thompson, Ken E.
    Geiwitz, Kevin L.
    SAFE Journal, 2000, 30 (02): : 190 - 196