External field effects on the resonant frequency of magnetically capped oscillators for magnetic resonance force microscopy

被引:0
|
作者
机构
[1] Miller, Casey W.
[2] Mirsaidov, Utkur M.
[3] Messina, Troy C.
[4] Lee, Yong J.
[5] Markert, John T.
来源
Markert, J.T. (cmiller@physics.utexas.edu) | 1600年 / American Institute of Physics Inc.卷 / 93期
关键词
Crystal oscillators - Magnetic anisotropy - Magnetic moments - Magnetization - Magnetoelectric effects - Natural frequencies - Nuclear magnetic resonance spectroscopy;
D O I
暂无
中图分类号
学科分类号
摘要
The resonant frequency shifts of magnetically capped oscillators under the applied magnetic field were investigated by using magnetic resonance force microscopy (MRFM) techniques. For low fields, magnetic moments were nearly perpendicular to the applied field while frequency decreased with increasing field value. At high field value, moments were nearly aligned with the filed whereas frequency increased with increasing field.
引用
收藏
相关论文
共 50 条
  • [41] Effects of air damping in noncontact resonant force microscopy
    Leveque, G
    Girard, P
    Belaidi, S
    Solal, GC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (11): : 4137 - 4144
  • [42] Resonant magnetic field sensor with frequency output
    Sunier, R
    Li, Y
    Kirstein, KU
    Vancura, T
    Baltes, H
    Brand, O
    MEMS 2005 Miami: Technical Digest, 2005, : 339 - 342
  • [43] Mechanical Generation of Radio-Frequency Fields in Nuclear-Magnetic-Resonance Force Microscopy
    Wagenaar, J. J. T.
    den Haan, A. M. J.
    Donkersloot, R. J.
    Marsman, F.
    de Wit, M.
    Bossoni, L.
    Oosterkamp, T. H.
    PHYSICAL REVIEW APPLIED, 2017, 7 (02):
  • [44] Resonant magnetic field sensor with frequency output
    Sunier, Robert
    Vancura, Tobias
    Li, Yue
    Kirstein, Kay-Uwe
    Baltes, Henry
    Brand, Oliver
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2006, 15 (05) : 1098 - 1107
  • [45] HIGH-FIELD MAGNETIC FORCE MICROSCOPY
    PROKSCH, R
    RUNGE, E
    HANSMA, PK
    FOSS, S
    WALSH, B
    JOURNAL OF APPLIED PHYSICS, 1995, 78 (05) : 3303 - 3307
  • [46] Variable-field magnetic force microscopy
    Jaafar, M.
    Gomez-Herrero, J.
    Gil, A.
    Ares, P.
    Vazquez, M.
    Asenjo, A.
    ULTRAMICROSCOPY, 2009, 109 (06) : 693 - 699
  • [47] Three dimensional magnetic resonance imaging by magnetic resonance force microscopy with a sharp magnetic needle
    Tsuji, S
    Yoshinari, Y
    Park, HS
    Shindo, D
    JOURNAL OF MAGNETIC RESONANCE, 2006, 178 (02) : 325 - 328
  • [48] Magnetic resonance force microscopy with a ferromagnetic tip mounted on the force detector
    Zhang, Z
    Hammel, PC
    SOLID STATE NUCLEAR MAGNETIC RESONANCE, 1998, 11 (1-2) : 65 - 72
  • [49] Magnetic exchange force microscopy using ferromagnetic resonance
    Xue Hui
    Ma Zong-Min
    Shi Yun-Bo
    Tang Jun
    Xue Chen-Yang
    Liu Jun
    Li Yan-Jun
    ACTA PHYSICA SINICA, 2013, 62 (18)
  • [50] Piezoresistive mechanical detector for magnetic resonance force microscopy
    Volodin, A
    Buntinx, D
    Brems, S
    Van Haesendonck, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (06):