CUSTOMER SERVICE DIRECT FROM TRANSMISSION LINES.

被引:0
|
作者
Wilde, R.L.
Carr, J.
机构
来源
| 1600年 / IEEE, New York, NY卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This paper reports on the design, testing and commercial operation of apparatus to tap a 120/240v service directly from a 72kv transmission line. The installed apparatus consists of a capacitive voltage divider, a standard 14. 4kv distribution transformer and auxiliary equipment for protection, regulation, resonance suppression etc. that together supply a 25kvA commercial load. Details are also given on variations of the basic circuit (use of inherent capacitance of transmission lines and inherent inductance of transformers) as well as on solutions to problems encountered during development (ferroresonance, regulation, flicker).
引用
收藏
相关论文
共 50 条
  • [21] CIRCLE DIAGRAM FOR IRREGULAR TRANSMISSION LINES.
    Zhestkov, V.F.
    Shevchenko, N.B.
    Telecommunications and Radio Engineering (English translation of Elektrosvyaz and Radiotekhnika), 1984, 38-39 (12): : 131 - 134
  • [22] CURRENT PROTECTION DEVICES FOR TRANSMISSION LINES.
    Nudel'man, G.S.
    Malyi, A.P.
    Shamis, M.A.
    Soviet electrical engineering, 1985, 56 (03): : 25 - 29
  • [23] NDT OF HIGH VOLTAGE TRANSMISSION LINES.
    Carter, R.A.
    Quick, D.G.
    Non-Destructive Testing - Australia, 1979, 16 (1-2): : 23 - 25
  • [24] APPROXIMATE FORMULAE FOR MICROSTRIP TRANSMISSION LINES.
    Cahill, L.W.
    Proceedings of the IREE Australia (Institution of Radio and Electronics Engineers), 1974, 35 (10): : 317 - 321
  • [25] TRANSMISSION CHARACTERISTICS OF TRANSMISSION LINES CONSTRUCTED WITH THE CASCADE CONNECTION OF UNIT EXPONENTIAL LINES.
    Sugawara, Goro
    Sato, Risaburo
    Nemoto, Yoshiaki
    Electronics and Communications in Japan (English translation of Denshi Tsushin Gakkai Zasshi), 1977, 60 (10): : 33 - 40
  • [26] RELIABILITY MODELING OF MULTIPLE OVERHEAD TRANSMISSION LINES.
    Nahman, Jovan M.
    Mijuskovic, Neso
    IEEE Transactions on Reliability, 1985, R-34 (03) : 281 - 285
  • [27] Voices of war: Stories of service from the home front and the front lines.
    Poremba, DL
    LIBRARY JOURNAL, 2004, 129 (19) : 74 - 74
  • [28] ACCURATE FAULT LOCATION ESTIMATOR FOR TRANSMISSION LINES.
    Richards, Gill G.
    Tan, Owen T.
    SAE Preprints, 1981,
  • [29] NON-CERAMIC INSULATORS FOR TRANSMISSION LINES.
    Cherney, E.A.
    Stonkus, D.J.
    Research Review - Ontario Hydro, 1981, (03): : 25 - 28
  • [30] Routing transmission lines. via Steiner trees
    Coulston, C
    Weissbach, R
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1576 - 1579